Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    International Journal of Mass Spectrometry and Ion Processes 132 (1994), S. 143-148 
    ISSN: 0168-1176
    Keywords: Fourier transform ; Lifetimes ; Metastable ions
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 73 (1989), S. 347-357 
    ISSN: 1573-2622
    Keywords: pattern electroretinogram ; Fourier analysis ; fovea ; retinal eccentricity ; spatial tuning ; visual field
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract To investigate the value of the extrafoveal pattern electroretinogram for evaluation of local retinal defects, electroretinographic responses to contrast reversal stimulation were recorded at various locations in the central and midperipheral retina. Normal values were established in 20 eyes, and spatial selectivity at different retinal eccentricities was determined in four eyes. The response amplitude was found to decrease steeply from the fovea until about 12° eccentricity and to decline only slowly thereafter. For central stimulation a clear attenuation for coarser patterns was observed. At 20° and at 30° eccentricity the spatial tuning function exhibited a bandpass characteristic, with the maximum amplitude shifting to lower spatial frequencies. Despite the relatively low peripheral amplitudes a satisfactory signal to noise ratio of the second harmonic responses can be obtained by Fourier analysis, which improves clinical applicability. The comparison of sensitivity in the upper and lower retina revealed a considerable asymmetry, with responses in the upper retina approximately 20% higher. No significant difference, however, was found when the temporal or nasal retina was stimulated. The reproducibility of these results is high enough to encourage clinical studies. A case of retinal venous branch occlusion exemplifies the applicability of this technique in eccentric fundus lesions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...