Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Iotrolan ; CT ; MR ; Arthrography ; Gd-DTPA ; Gleuchumeral joint
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The role of conventional arthrography versus computed tomography (CT) arthrography of the glenohumeral joint using iotrolan was evaluated in patients with different shoulder problems. In addition, a diagnostic combination of conventional and CT arthrography was compared with magnetic resonance (MR) arthrography of the glenohumeral joint. Two diagnostic protocols were used. Protocol 1: conventional followed after 30 min by CT arthrography of 37 joints using a double contrast technique with iotrolan 300. Protocol 2: conventional followed after 90–180 min by MR arthrography in 20 patients using a single-contrast technique with 10 ml iotrolan 300 and 1 ml gedopentetate dimeglumine 500 mM. Ten patients also underwent CT arthrography. Neither patient group experienced contrast-related complications. Image quality was good for all conventional arthrograms, excellent in 45/47 CT arthrograms and good in 20 MR arthrograms. CT and MR arthrography were diagnostically valuable in many patients. We conclude that glenohumeral joint evaluation should be perfomed first using conventional or CT arthrography. Iotrolan has proven to be highly reliable and safe in these applications. Iotrolan in combination with gadopentetate dimeglumine, permits MR arthrography following completion of the standard examinations if necessary.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1084
    Keywords: Key words: Breast radiography ; Technology ; Breast neoplasms ; calcification ; Radiation dose
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of our study was to evaluate a mammography unit capable of magnification of up to fourfold at an equivalent or lower dose than with current systems. A prototype mammography tube with an electron-beam-focusing technology resulting in a focal spot size of 40–120 μm was combined with a highly intensifying screen-film system. To evaluate contrast-detail resolution, phantom radiographs were performed with the prototype magnification mammography system using a magnification factor of 1.7 for survey views and a magnification factor of 4.0 for spot views. They were compared with unmagnified survey views and magnification spot views (magnification factor 1.9) of a state-of-the-art mammography system. The radiation exposure was measured and mean glandular doses were calculated. The contrast-detail resolution with both prototype (m = 1.7) and conventional (m = 1.1) survey views was equivalent while the entrance dose and the mean glandular dose were approximately 50 % lower with the prototype. For spot views, the contrast-detail resolution was substantially higher for the prototype than for conventional magnification while the dose was equivalent. Dose reduction and improved detail resolution are possible with this new technology.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...