Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    European journal of applied physiology 64 (1992), S. 292-297 
    ISSN: 1439-6327
    Schlagwort(e): Aerobic power ; Anaerobic power ; Training
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Seven female and eight male elite junior skaters performed cycle ergometer tests at four different times during the 1987/1988 season. The tests consisted of a Wingate-type 30-s sprint test and a 2.5-min supramaximal test. The subjects were tested in February, May and September 1987 and in January 1988. Maximal oxygen consumption was measured during the 2.5-min test. With the exception of the maximal oxygen consumption of the women in May which was about 6% lower than in the other three tests, no seasonal changes in the test results could be observed —this, in spite of a distinct increase in training volume (from 10 to more than 20 h · week−1) and training intensity in the course of the season. When the test data were compared to those of elite senior skaters, it appeared that the junior skaters showed the same values for mean power output during the sprint test [14.2 (SD 0.4) W · kg−1 for the men and 12.6 (SD 0.5) W · kg−1 for the women] and maximal oxygen consumption [63.1 (SD 2.8) ml· kg−1 · min−1 for the men and 55.3 (SD 3.5 ml · kg−1 · min−1 for the women, respectively] as found for senior skaters. It seemed, therefore, that the effects of training in these skaters had already levelled off in the period before they participated in this investigation. In contrast to previous studies, no relationship could be shown between the test results and skating performance. This was most likely due to the homogenous character of the groups (mean standard deviations in power and oxygen consumption were only 5%). It was concluded that the present cycle tests used to measure aerobic and anaerobic power were obviously not of use in evaluating seasonal changes in performance in these groups of highly trained athletes.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1573-739X
    Schlagwort(e): Ceftazidine ; Cefuroxime ; Groin ; Implants, artificial ; Vascular surgery ; Pharmacokinetics
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract The kinetics of systemically and locally administered cefuroxime or ceftazidime in wound fluid were investigated in the period after vascular prosthetic implantation. Cefuroxime or ceftazidime was administered intravenously in patients. Simultaneously 250 mg ceftazidime or cefuroxime was added to preclotted blood. Locally administered antibiotics could not be detected in our samples. In groin fluid samples 24–48 h after the operation the average concentration of cefuroxime was 8.3 and of ceftazidime 5.0 mg/l. The decline of the concentration of cefuroxime or ceftazidime in groin fluid seems to be much slower than one would expect from the half-lives of the antibiotics. We conclude that cefuroxime and to a lesser extent ceftazidime are suitable as prophylactic agents in arterial reconstruction.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...