Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Key words: Stereolithography ; Rapid prototyping ; Computed tomography ; Calcaneal fracture ; ROC curves
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The purpose of this study was to evaluate and compare the diagnostic performance of stereolithography vs workstation-based three-dimensional (3D) reformations in intra-articular calcaneal fractures. A total of 30 intra-articular calcaneal fractures were examined using standard radiographs, coronal CT scans, and 2D and 3D reformations. The CT data were transferred to an outside institution, and stereolithograms were produced from photopolymer resin employing a laser beam system. 3D reformations and stereolithograms were analyzed in a blinded fashion by two staff radiologists. Receiver-operating-characteristic (ROC) curves were obtained for six clinically significant fracture components. Standard radiographs, coronal CT scans, and 2D reformations served as the standard of reference. The area under the ROC curves for 3D reformations and stereolithograms were 1.0 and 0.98 for abnormal tuber angles, 0.91 and 0.91 for anterior and middle talo-calcaneal joint involvement, 0.90 and 0.95 for involvement of the posterior talo-calcaneal joint, 0.65 and 0.78 for the presence of a lateral bulge, 0.80 and 0.81 for the involvement of the calcaneocuboidal joint, and 0.62 and 0.67 for the presence of a “tongue-type” fracture. No statistically significant difference was demonstrated for the two methods (Wilcoxon signed-rank test, p = 0.138). Based on our results stereolithograms did not prove to be statistically superior to workstation-based 3D reformations. Stereolithograms may still be useful for teaching purposes and for surgical planning at a thinking-efficacy level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1084
    Keywords: Key words: Thyroid ; Biopsy ; Interventional MR ; MR guidance ; Stereotaxis ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy thyroid lesions, and to compare resolution between ultrasound and interventional MR imaging in the evaluation of thyroid lesions. Twenty thyroid lesions of 18 patients were interactively biopsied using a 0.5-T superconducting open magnet system. Stereotactic localization of the needle and imaging was accomplished using T1-weighted gradient-recalled-echo (GRE) images. Representative cytological material was retrieved in 16 of 20 lesions (benign cystic or colloid goiter: n = 14; one de Quervain's thyroiditis and one follicular neoplasia). Lesions smaller than 1.5 cm detected by ultrasound could not be visualized adequately on GRE images. Lesions smaller than 1.5 cm were successfully biopsied by ultrasound (three colloid and haemorrhagic goiters and one adenoma). Magnetic-resonance-guided interactive biopsies and positioning of non-ferromagnetic needles in the thyroid gland are technically feasible and safe. Compared with high-resolution ultrasound, lesions larger than 1.5 cm can be adequately visualized and biopsied. Magnetic-resonance-guided placement of non-ferromagnetic needles is no substitute for high-resolution ultrasound in clinical work-up of thyroid lesions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...