Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (7)
  • Chemistry  (5)
  • Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm  (2)
  • 1
    ISSN: 1432-2218
    Keywords: Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Advanced laparoscopic procedures are more commonly performed in elderly patients with cardiac disease. There has been limited data on the use of pulmonary artery catheters (PAC) and transesophageal echocardiography (TEE) to monitor hemodynamic changes. Methods: We prospectively studied eight patients undergoing laparoscopic assisted abdominal aortic aneurysm repair. All patients had a PAC and all but one had an intraoperative TEE. Data included heart rate (HR), temperature (temp), pulmonary artery systolic (PAS) and diastolic (PAD) pressures, mean arterial pressure (MAP), central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), cardiac index (CI), mixed venous oxygen saturation (MVO2), and oxygen extraction ratio (O2Ex) and was obtained prior to induction, during insufflation, after desufflation, during aortic cross-clamp, and at the end of the procedure. End diastolic area (EDA), a reflection of volume status, was measured on TEE. ANOVA was used for data analysis. Results: No changes were noted in HR, temp, PAS, PCWP, CI, MVO2, and O2Ex. PAD and CVP were greater during insufflation compared with baseline and aortic cross-clamp without associated changes in EDA. MAP was higher at baseline compared with all other times during the procedure. Conclusions: Insufflation increased PAD and CVP. However, volume status as suggested by EDA and PCWP did not change. These data question the reliability of hemodynamic measurements obtained from the PAC during pneumoperitoneum and suggest that TEE may be sufficient for evaluation of volume status along with the added benefit of timely detection of ventricular wall motion abnormalities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 1136-1139 
    ISSN: 1432-2218
    Keywords: Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Laparoscopic surgery decreases postoperative pain and length of hospital stay. Whether laparoscopically assisted abdominal aortic aneurysm (AAA) repair can be safely and reliably performed is unknown. This prospective study was designed to establish the feasibility of laparoscopically assisted AAA repair and its effects on intraoperative and postoperative variables. Methods: With IRB approval, 10 patients with infrarenal AAA requiring a tube graft underwent laparoscopically assisted AAA repair. The procedure consisted of laparoscopic dissection of the aneurysm neck and iliac vessels. Then, through an 8–11-cm minilaparotomy, a standard endoaneurysmorrhaphy was performed. Data included laparoscopic and total operative times, blood loss, fluid requirements, duration of nasogastric suction (NGT), and lengths of intensive care unit (ICU) and postoperative hospital stays. Results: Laparoscopically assisted AAA was completed in nine of 10 patients. The first patient was converted to a standard incision because the aneurysm neck could not be adequately dissected. Laparoscopic and total operative times were 1.8 ± 0.4 and 4.5 ± 0.7 h, respectively. Mean blood loss was 1 ± 0.6 l. Intraoperative fluid requirement was 6.6 ± 1.3 l. The duration of NGT suction was 1.8 ± 1.0 days. The ICU stay was 2.1 ± 0.8 days and hospital stay was 6.7 ± 2.5 days. There were two minor complications and no deaths. Conclusions: Laparoscopically assisted AAA repair is technically feasible with acceptable blood loss, operative time, morbidity, and mortality. Potential advantages may be early removal of the NGT and shorter ICU and hospital stays. Prospective randomized trials are needed to determine if laparoscopically assisted AAA repair is advantageous.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 59 (1998), S. 351-359 
    ISSN: 0006-3592
    Keywords: bioreactor ; high density ; insect cells ; perfusion ; Sf9 ; ultrasonic filter ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The baculovirus/insect cell expression system has provided a vital tool to produce a high level of active proteins for many applications. We have developed a very high-density insect cell perfusion process with an ultrasonic filter as a cell retention device. The separation efficiency of the filter was studied under various operating conditions. A cell density of over 30 million cells/mL was achieved in a controlled perfusion bioreactor and cell viability remained greater than 90%. Sf9 cells from a high-density culture and a spinner culture were infected with two recombinant baculoviruses expressing genes for the production of human chitinase and monocyte-colony inhibition factor. The protein yield on a cell basis from infecting high-density Sf9 cells was the same as or higher than that from the spinner Sf9 culture. Virus production from the high-density culture was similar to that from the spinner culture. The results show that the ultrasonic filter did not affect insect cells' ability to support protein expression and virus production following infection with baculovirus. The potential applications of the high-density perfusion culture for large-scale protein expression from Sf9 cells are also highlighted. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 59:351-359, 1998.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 35 (1995), S. 144-150 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The objective of the current paper was to extend the relationships between complex polymer structures and microwave absorptivity that were formulated in the first three papers of this series (1-3). The microwave processing of composite and polymeric blends via a cylindrical resonance wave cavity and a rectangular standing wave applicator is described. These polymeric materials were irradiated in a low power (〈 100W) electric field at 2.45 GHz. Graphite-epoxy laminates were processed in both standing and traveling wave applicators. Rapid heating and curing were achieved in both cases. An observation of significance was that, with proper tuning of the traveling wave device (the precursor of a protable repair tool), it proved to be highly effective in processing. Additionally, a compatible blend of poly(methyl methacrylate) and poly(vinylidene fluoride) was heated in and applicator and the rates of temperature rise were demonstrated to depend upon morphology.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 60 (1996), S. 1569-1574 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The curing characteristics of unaccelerated sulfur vulcanization of ENR 25 and ENR 50 were studied in the temperature range from 100-180°C. The range of sulfur loading was from 1.5 to 6.5 phr. The scorch time was determined by Mooney Shearing Disk Viscometer whereas the initial cure rate, maximum torque, and reversion properties were obtained from the Moving Die Rheometer (MDR 2000). Results shows that ENR 25 gives a longer scorch time than ENR 50, an observation similar to that in an accelerated system reported earlier. For temperature 〈 120°C, scorch time depends exponentially on sulfur loading for both rubbers. However, this dependence diminishes as temperature is increased. This observation is attributed to the availability of activated sulfur molecules for vulcanization. The initial cure rate and maximum torque increases with increasing sulfur loading. ENR 50, however, exhibits higher value than ENR 25, suggesting faster cure in the former. For a fixed sulfur loading, reversion is a time and temperature-dependent phenomenon. It decreases with increasing sulfur loading because of the increase of cross-linking density for both rubbers stuided. © 1996 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 61 (1996), S. 1479-1486 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: In this paper, the blends of the carbon dioxide copolymer, poly(propylene carbonate) (PPC), with nitrile rubber (NBR) were studied by DSC, DMA, TEM and TG. PPC can enhance the mechanical properties of NBR, while oil resistance and tensile set at break of NBR/PPC systems were as good as that of NBR. The coagent of triallylisocyanurate or maleic anhydride with carbon black can much improve the curing efficiency of dicumyl peroxide in NBR/PPC systems. © 1996 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 69 (1997), S. 1278-1278 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...