Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 12 (1998), S. 221-225 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Vorhofseptumdefekt – Interventioneller Verschluß– Echokardiographie ; Key words Atrial septal defect – transcatheter closure – echocardiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Surgical closure of atrial septal defects can nowadays be performed without preoperative cardiac catheterization. For a transcatheter closure, however, x-ray exposure has been indispensable. We report a closure of an atrial septal defect under transesophageal echocardiography without fluoroscopy. A nine year old girl with an 11 mm atrial septal defect centrally located in the oval fossa was elected for transcatheter closure. Doppler-echocardiographically estimated Qp/Qs was 1.7:1. Oxymetric Qp/Qs was 1.6:1. After sedation with midazolam and propofol a diagnostic and interventional catheterization was performed without fluoroscopy. Under transesophageal echocardiography, the defect was sized over the wire with a 5F balloon catheter. The distance to the right pulmonary veins was 10 mm, to the coronary sinus and to the mitral valve 8 mm, respectively. Under transesophageal echocardiography, an 11 mm Amplatzer Septal Occluder was placed into the defect. Complete closure was achieved and no complications were encountered. We conclude that in selected cases with an atrial septal defect located in the oval fossa and clear-cut echocardiographic findings, an Amplatzer Septal Occluder can be safely deployed under echocardiographic guidance alone.
    Notes: Zusammenfassung Der operative Verschluß eines Vorhofseptumdefekts (ASD) kann heutzutage ohne präoperative Katheteruntersuchung durchgeführt werden. Für den interventionellen Verschluß unter Durchleuchtung ist jedoch eine Strahlenexposition unvermeidbar. Wir berichten über einen interventionellen ASD-Verschluß allein unter transösophagealer Ultraschallkontrolle. Ein neun Jahre altes Mädchen mit einem 11 mm großen ASD vom Secundum-Typ wurde zum interventionellen ASD-Verschluß vorgestellt. Das Shuntvolumen über den Defekt wurde Doppler-echokardiographisch mit Qp/Qs=1,7:1 und oxymetrisch mit Qp/Qs=1,6:1 bestimmt. Unter Sedierung mit Midazolam und Propofol wurde sowohl die Katheterdiagnostik als auch die Intervention ohne Durchleuchtung durchgeführt. Die Defektgröße wurde unter transösophagealer Echokardiographie mit einem 5F Ballonkatheter ermittelt: Der Defekt war 11 mm groß, der Abstand zu den rechten Lungenvenen betrug 10 mm, zum Koronarsinus und zur Mitralklappe jeweils 8 mm. Unter transösophagealer Echokardiographie konnte komplikationslos ein 11 mm großer Amplatzer Septal Occluder in den Defekt plaziert werden. Es bestand kein Restshunt. Der hier berichtete Fall demonstriert, daß die Technik des interventionellen ASD-Verschlusses inzwischen so ausgereift ist, daß sowohl Diagnostik, Sizing als auch Implantation eines transvenös eingebrachten Amplatzer Septal Occluders ganz ohne Röntgenstrahlung möglich ist.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Monatsschrift Kinderheilkunde 145 (1997), S. 1071-1075 
    ISSN: 1433-0474
    Keywords: Schlüsselwörter Ultraschall ; Gehirn ; Angeborene Herzfehler ; 3dimensionale Rekonstruktion ; Key words Three-dimensional reconstructions ; Ultrasound of the brain
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Objective: We assessed the utility of 3D ultrasound in detecting morphological changes of cerebral anatomy in newborns. Methods: Transfontanel cross-sectional ultrasound scans were obtained in standardized coronal and median sagittal planes. Subsequently, rotational scanning was used to acquire the multiple sequential cross-sections of the brain. A conventional 5 MHz transducer was rotated 180 degrees by a computer-controlled stepper motor and an image of the brain was obtained at each step of motion to obtain a three-dimensional dataset. Data was stored in the image processing computer which allowed for off-line three dimensional reconstruction of different brain regions. Results: Cavity of lateral ventricle, and periventricular brain parenchyma could be reconstructed in all. Accurate estimation of size and volume of ultrasonographically visible pathological brain lesions could be performed. Epicortical and subarachnoidal space could be reconstructed in all and allowed detection of hemorrhage in one case which was not detected by conventional ultrasound. Conclusion: 3D reconstruction of different areas of the brain may provide additional quantitative information on size and volume of the internal ventricle and better understanding of the topographical aspects and the extension of intra- and periventricular morphological abnormalities than conventional cross-sectional ultrasound.
    Notes: Zusammenfassung Fragestellung: Ausgehend von eigenen Erfahrungen mit der 3dimensionalen Echokardiographie wurde versucht, auch ultrasonographische transfontanelle Studien 3dimensional zu rekonstruieren und auf ihren Informationsgehalt zu untersuchen. Methode: Es wurden 16 Neugeborene und Säuglinge (Alter 4 Tage – 3 Monate, Median 12 Tage) untersucht. Ein konventioneller 5-MHz-Schallkopf wurde auf der anterioren Fontanelle plaziert und von einem computergesteuerten Motor im inneren Lumen eines offenen Zylinders um 180° um seine vertikale Achse gedreht. Bei jeder Drehung um jeweils 1° wurde eine Schicht des Gehirns aufgenommen, so daß 180 Schichten erhalten wurden, welche den 3dimensionalen Datensatz bilden. Innerhalb des Datensatzes können beliebig im Raum orientierte Schnittebenen rekonstruiert werden. Ergebnisse: Bei allen Patienten gelang es, Datensätze aufzunehmen, welche qualitativ so gut waren, daß sie später 3dimensional rekonstruiert werden konnten. Die Daten konnten ohne Sedierung und in weniger als 60 s aufgenommen werden. Rekonstruktionen des Gehirns dauerten 2–33 min. Es konnten neue transversale Schnittebenen des Schädels rekonstruiert werden, welche bisher nicht erhältlich waren. Neue Informationen konnten über subarachnoidal gelegene Hirnläsionen sowie die räumliche Ausdehnung von Parenchymblutungen gewonnen werden. Schlußfolgerungen: Dieses neue bildgebende Verfahren könnte in Zukunft quantitative und qualitative diagnostische Informationen der herkömmlichen Ultrasonographie verbessern.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...