Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Radiography  (2)
  • Key words Helical CT  (1)
  • Key words: Breast  (1)
  • 1
    ISSN: 1432-2161
    Schlagwort(e): Key words Anterior cruciate ligament reconstruction ; ACL ; Isometry ; MRI ; Radiography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  Objective. Correct placement of tunnels for anterior cruciate ligament (ACL) reconstruction is of prime importance for the clinical outcome of the patient. In this study, the possibility of using MRI to document tunnel placement and provide a more comprehensive report following ACL reconstruction was explored at no additional cost in patients scheduled for routine knee MRI. Design and patients. One year after ACL reconstruction, 45 patients underwent clinical examination (IKCD score), radiographic examination, and MRI using a 1.5-T unit. Results. Twenty patients with good tibial and femoral attachment results were found at clinical examination to have a stable knee joint with a full range of motion. In 25 patients with suboptimal placements, examination showed either a stable knee with a decreased range of motion or instability with a normal range of motion. Conclusion. Patients’ clinical outcome, and the radiographic and MRI findings, correlated closely with the quality of operative tunnel placement. A record of this finding is important for completeness of the radiological report. Furthermore the MRI findings can be used to improve the surgical quality of tunnel placement. Because tunnel placement can be shown adequately with radiography, however, MRI cannot be justified for this reason alone, so such assessment is advised only when MRI is needed to show all postoperative features.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-2102
    Schlagwort(e): Schlüsselwörter Spiral-CT ; Virtuelle Endoskopie ; Larynx ; Key words Helical CT ; Virtual endoscopy ; Larynx
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Summary This pilot study investigated the feasibility and clinical value of high-resolution virtual real-time laryngoscopy based on helical CT data sets. Nine patients with laryngeal pathology (three with tumors of the vocal cords, two laryngeal carcinomas, one with invasion of the larynx by thyroid carcinoma and six subglottic stenoses) underwent examination by helical CT at a collimation of 1 mm. Following acquisition, the images were processed at a workstation with standard visualization software, such that virtual endoscopy (VE) in real time was possible. The images were then compared with the findings of conventional endoscopy. Because of swallowing artifacts, reconstruction failed in 2 of 12 patients. None of the carcinomas of the vocal cords was recognized at VE or in the cross-sectional CT images. VE provided the correct diagnosis in 8 of 12 cases (laryngeal tumors, subglottic stenoses). Virtual laryngoscopy is capable of simulating the visual findings of endoscopy in cases of laryngeal tumors and subglottic stenoses. Small tumors of the vocal cords are not adequately visualized. The major problem affecting results is motion artifacts resulting from involuntary swallowing.
    Notizen: Zusammenfassung Im vorliegenden Beitrag wird eine Pilotstudie zur Überprüfung der Machbarkeit und des klinischen Nutzens einer hochauflösenden virtuellen Echtzeitlaryngoskopie aus Spiral-CT-Datensätzen vorgestellt. 12 Patienten mit Erkrankungen im Kehlkopfbereich (3 Stimmlippentumore, 2 Larynxkarzinome, ein in den Larynx eingebrochenes Schilddrüsenkarzinom und 6 subglottische Stenosen) wurden mittels hochauflösender Spiral-CT (Kollimation 1 mm) untersucht. Anschließend wurden die Bilder auf einer Workstation mit einer standardmäßigen Visualisierungssoftware so rekonstruiert, daß eine virtuelle Endoskopie (VE) in Echtzeit möglich wurde, welche der herkömmlichen Fiberendoskopie gegenübergestellt wurde. 2 der 12 Patienten waren bedingt durch Schluckartefakte nicht zu rekonstruieren. Keines der Stimmlippenkarzinome war in der VE oder den Querschnittsbildern zu erkennen. In 8 von 12 Fällen war die VE diagnostisch (Larynxtumore, subglottische Stenosen). Die virtuelle Laryngoskopie in der hier beschriebenen Technik vermag Larynxtumoren und subglottische Stenosen, nicht aber kleine Stimmbandtumoren in einer dem Kliniker vertrauten endoskopischen Sichtweise darzustellen. Hauptproblem sind Bewegungsartefakte durch unwillkürliche Schluckbewegungen.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1433-0563
    Schlagwort(e): Schlüsselwörter Flächendosisprodukt ; Dosimetrie ; Durchleuchtung ; Radiographie ; Miktionszysturethrographie ; Key words Dose-area product ; Dosimetry ; Fluoroscopy ; Radiography ; Voiding cystourethrography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Summary Objective: Determination of the proportion of the dose-area product caused by fluoroscopy at voiding cystourethrography in children, using digital image intensifier technology. Patients and methods: Using computer-assisted dosimetry, we determined the dose-area product and the respective proportions of the dose-area product caused by fluoroscopy and radiography as well as the number of radiographs taken at a given examination of 40 children (8 children less than 2 years old, 15 children between 2 and 6 years old and 17 children between 6 and 15 years old). Results: The computer software program correctly differentiated between fluoroscopy and radiography in 80 % of cases. Incorrect results were primarily observed in newborns and young children. The total radiation dose ranged in relation to patient age from 22 to 651 cGy × cm2. Fluoroscopy was responsible for an average 78 % of the applied radiation dose. Conclusion: Computer-assisted dosimetry is useful in determining the proportion of the dose-area product caused by fluoroscopy in older children undergoing voiding cystourethrography. When image intensifier technology is used, this accounts for more than 75 % of the total radiation dose. The method is not suitable for use in small children.
    Notizen: Zusammenfassung Ziel: Bestimmung des Anteils der Durchleuchtung am Gesamtflächendosisprodukt beim Kindermiktionszysturethrogramm in digitaler Bildverstärkertechnik. Material und Methode: Bei 40 Kindern (8 Kinder 〈 2 Jahre, 15 Kinder zwischen 2 und 6 Jahren und 17 Kinder zwischen 6 und 15 Jahren) wurden PC-gestützt die Anzahl der Zielaufnahmen, deren Anteil am Gesamtflächendosisprodukt sowie der durchleuchtungsbedingte Anteil am Gesamtflächendosisprodukt ermittelt. Ergebnisse: In 80 % der Fälle ermöglichte der Einsatz des Computerprogramms eine korrekte Differenzierung zwischen Fluoroskopie und Radiographie. Falsche Ergebnisse fanden sich hauptsächlich bei Neugeborenen und Kleinkindern. Die Gesamtstrahlenbelastung variierte abhängig vom Patientenalter zwischen 22 und 651 cGy × cm2, durchschnittlich betrug der Anteil der Durchleuchtung 78 %. Schlußfolgerung: PC-gestützt ist es möglich den Anteil der Durchleuchtung am Gesamtflächendosisprodukt bei älteren Kindern, die sich einem Miktionszysturethrogramm unterziehen, zu ermitteln. Dieser beträgt bei Verwendung der digitalen Bildverstärkertechnik mehr als 75 %. Bei Neugeborenen und Kleinkindern versagt die Methode.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1432-1084
    Schlagwort(e): Key words: Breast ; Parenchymal pattern ; MR imaging ; Contrast enhancement ; MR mammography ; Menstruation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time–intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...