  • Human triceps surae  (1)
  • Occupational Health and Environmental Toxicology  (1)
  • 1
    ISSN: 0197-8462
    Keywords: dielectric heaters ; body currents ; SARs ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Data are presented on ankle-specific SARs and foot currents as a function of strengths of radio-frequency electromagnetic fields encountered by operators of dielectric heaters. The determination of foot currents was based on near-field exposures in which reactive coupling dominates, and which can result in substantial SARs in exposed workers. The operators were located less than one wavelength from - usually within one meter of - the dielectric heaters, which generated fields at frequencies from 6.5 to 65 MHz. At distances normally assumed by workers, maximal strengths of electric fields ranged from 104 to 2.4 × 106 V2/m2; maximal strengths of magnetic fields ranged from 5.0 × 10-3 to 33.3 A2/m2. Currents through both feet to ground were measured while operators stood where they normally worked. Maximal currents ranged from 3 to 617 mA, rms. Nearly 27 percent of the dielectric heaters induced foot currents that exceeded the 200-mA limit that has been proposed for a new ANSI C95.1 standard. Twenty percent of the heaters induced foot currents that exceeded 350 mA. SARs in ankles were calculated from foot currents, and they approximated 5 W/kg at 100 mA, 29 W/kg at 250 mA, and 57 W/kg at 350 mA. The maximal SAR in the ankle was ∼ 176 W/kg at 617 mA. © 1992 Wiley-Liss, Inc.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 30 (1992), S. 600-604 
    ISSN: 1741-0444
    Keywords: Contractile properties ; Fibre types ; Human triceps surae ; Muscle contraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The purpose of the study was to compare the contractile properties determined from an electrically stimulated twitch with histochemically determined fibre type parameters of the human triceps surae. Muscle samples were obtained from the medial head of the gastrocnemius of ten male athletes. Ages ranged from 20 to 29 years. Muscle samples from the belly of the medial gastrocnemius muscle were obtained using the needle biopsy technique. The samples were treated histochemically for myosin ATPase to classify the fibres as either slow twitch (ST) or fast twitch (FT) and to determine fibre areas. Surface electrical stimulation was used to determine muscle twitch parameters. The contractile variables of the muscle twitch were latency (L), time to peak force (TPF), peak force (PF), half-contraction time (1/2 CT) and half-relaxation time (1/2 RT). Backward elimination procedures for dependent variables were used to determine which contractile properties best represented the histochemical profile of the muscles. Prediction formulas were developed for FT and ST percentages (R2=0·98, p〈0·001), relative area percentage (R2=0·87, p〈0·001), and ST area (R2=0·85, p〈0·01). It was concluded that the use of the electrotensiometer (ETM) protocol was a valid testing procedure when studying physiological relationships of histochemical properties in intact human skeletal muscle.