Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; On-line preconcentration ; Polar pollutants ; Water (tap and surface)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An isocratic column liquid chromatographic system with UV absorbance detection at 230 nm has been developed for the rapid trace-level determination of a large number of polar pollutants in water. The systems contains two precolumns, in series, which are packed with a styrenedivinylbenzene (PLRP-S) polymer. The second precolumn is also loaded with sodium dodecylsulphate before use. Each precolumn is combined with a PLRP-S analytical column, and aqueous acetonitrile mixtures (pH 3) are used for the separation of neutral as well as acidic and basic pollutants. With 10-ml water samples the detection limits for all analytes, in tap water, are in the low to sub μg/l range. Relevant analytical data are reported and the advantage of using a dodecylsulphate-loaded precolumn over a cation-exchange precolumn is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Atomic emission and MS detection ; Solid-phase extraction ; Aqueous samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC systems to enable the determination of microcontaminants at the 0.02–1 μg L−1 level in 7–50 mL of aqueous sample. The screening was limited to compounds present in at least one heteroatom-selective GC-AED trace above a predetermined concentration level. These compounds were identified by their partial formulae (AED) and the corresponding mass spectra, which were obtained from the GC-MS chromatogram via the retention index concept. The potential of the approach was demonstrated by the identification of target compounds as well as all unknowns present in tap and waste water above the predetermined threshold of 0.05 μg L−1 (tap water) or 0.5 μg L−1 (waste water).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Atomic emission detection ; Aqueous samples ; Solid-phase extraction ; Organophosphorus pesticides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An on-line, solid-phase extraction gas chromatography atomic-emission detection (SPE-GC-AED) system has been set up using an on-column interface to transfer 100 μl of desorbing solvent to the GC part of the system. Analytical characteristics such as recovery, precision and linearity of calibration plots were comparable with those of the off-line combination of SPE-GC-AED using organophosphorus pesticides as test compounds. The fully on-line set-up causes a marked improvement in detection because of the quantitative transfer of the analytes from the SPE module to the GC: detection limits are as low as 5–20 ng l−1 for the analysis of 10 ml raw and spiked surface water samples using the phosphorus channel. Detection levels can be further enhanced by processing up to 100 ml samples. The integrated analytical system is robust. The potential of the on-line set up has been demonstrated for the analysis of surface water and waste water.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 793-796 
    ISSN: 0935-6304
    Keywords: Microcolumn liquid chromatography ; Flame photometric detection ; Organophosphorus compounds ; On-line preconcentration ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The potential of an interface for the on-line coupling of microcolumn liquid chromatography (LC)and a flame photometric detector (FPD) has been further investigated. With the micro-LC/FPD system, relatively high-molecular-weight polar compounds such as cyclic adenosine monophosphate, guanosine monophos- phate, glucose monophosphate, fructose monophosphate, and phytic acid were separated and selectively detected. In order to increase the sensitivity, on-line preconcentration with a microprecolumn inserted in the rotorof a Valcovalve has been applied. Preliminary results have shown that an injection volume of at least 500 1-11 water containing organophosphorus acids at a 5-50 ng/rnl concentration level is possible.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...