Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (4)
  • Cardiac surgery  (2)
  • Origin assignment  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 207 (1998), S. 237-243 
    ISSN: 1431-4630
    Keywords: Key words 2H-Nuclear magnetic resonance ; 13C ; 18O-Isotope ratio mass spectrometry ; Glycerol ; Origin assignment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  The adulteration of wine with glycerol is considered to be a problem in European wine-producing countries. The latest control methods are mainly based on the detection of impurities from commercial products, but suffer from the raising efficiency of the purification processes. As there is little chance of being able to identify glycerol from different sources on the basis of a method which uses only one isotope, a multielement approach was tested. Glycerol from wine showed the lowest relative enrichment with D, mainly in position C-2, a relatively high 18O content, and very negative δ13C values, which significantly correlated with those of ethanol from the same wines. The isotopic data of glycerol samples from different sources were in agreement with those given by indices of origin (impurities). These data allowed us to identify the origin of these glycerol samples, i.e. whether they were produced industrially or synthesised by animals or plants. Glycerol of plant origin was most similar to glycerol found in wine. The combination of several isotopic data by discriminance analysis yielded clusters of data obtained from glycerol samples of similar origin. Taking into account the characteristics of possible mixtures, proof that wine has been adulterated depends on the origin and isotope levels of the added compound. This study showed that it is possible to prove that wine has been adulterated with glycerol from other sources when the latter is present at a concentration of 15% of the total glycerol content.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 208 (1999), S. 400-407 
    ISSN: 1431-4630
    Keywords: Key words Wine ; Oxygen isotopes ; Adulteration control ; Origin assignment ; European Union data bank
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  The application of oxygen isotope analysis to wine water (according to EU regulation no. 822/97) to determine a wine's origin, and check that it has not been adulterated is gaining increasing importance in both laboratories and industry. Using samples of Italian, French and German wines from the EU wine data bank (EU-DB), good agreement between the results from participating laboratories was demonstrated. Close correlations between the oxygen isotope contents of must and related wine water were found for samples from all countries. Based on the results of the δ18O values for EU-DB wines from 1991 to 1996 from Italy, France and Germany, we describe and discuss the main factors which are responsible for the variation of the oxygen isotope ratios of wine water. The examination of spiked samples demonstrated the usefulness of δ18O analysis for the detection of the watering down of wine. The possibility of origin assignment, preferably if the determination of the δ18O value by isotope ratio mass spectrometry (IRMS) is employed together with the determination of the site-specific hydrogen isotope content of wine ethanol by 2H-NMR and the measurement of δ13C values of ethanol by IRMS, is outlined.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Weaning CPAP ; BiPAP ; Extravascular lung water ; Cardiac surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To evaluate the effects of continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP) on extravascular lung water during weaning from mechanical ventilation in patients following coronary artery bypass grafting. Design Prospective, randomized clinical study. Setting Intensive care unit at a university hospital. Patients Seventy-five patients following coronary artery bypass grafting. Interventions After extubation of the trachea, patients were treated for 30 min with CPAP via face mask (n=25), with nasal BiPAP (n=25), or with oxygen administration via nasal cannula combined with routine chest physiotherapy (RCP) for 10 min (n=25). Measurements and results Extravascular lung water (EVLW), pulmonary blood volume index (PBVI) and cardiac index (CI) were obtained during mechanical ventilation (T1), T-piece breathing (T2), interventions (T3), spontaneous breathing 60 min (T4) and 90 min (T5) after extubation of the trachea using a combined dye-thermal dilution method. Changing from mechanical ventilation to T-piece breathing did not show any significant differences in EVLW between the three groups, but a significant increase in PBVI from 155±5 ml/m2 to 170±4 ml/m2 could be observed in all groups (p〈0.05). After extubation of the trachea and treatment with BiPAP, PBVI decreased significantly to 134±6 ml/m2 (p〈0.05). After treatment with CPAP or BiPAP, EVLW did not change significantly in these groups (5.5±0.3 ml/kg vs 5.0±0.4 ml/kg and 5.1±0.4 ml/kg vs 5.7±0.4 ml/kg). In the RCP-treated group, however, EVLW increased significantly from 5.8±0.3 ml/kg to 7.1±0.4 ml/kg (p〈0.05). Sixty and 90 min after extubation, EVLW stayed at a significantly higher level in the RCP-treated group (7.5±0.5 ml/kg and 7.4±0.5 ml/kg) than in the CPAP-(5.6±0.3 ml/kg and 5.9±0.4 ml/kg). No significant differences in CI could be observed within the three groups during the time period from mechanical ventilation to 90 min after extubation of the trachea. Conclusions Mask CPAP and nasal BiPAP after extubation of the trachea prevent the increase in extravascular lung water during weaning from mechanical ventilation. This effect is seen for at least 1 h after the discontinuation of CPAP or BiPAP treatment. Fuether studies have to evaluate the clinical relavance of this phenomenon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1238
    Keywords: Key words Weaning ; CPAP ; BiPAP ; Extravascular lung water ; Cardiac surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To evaluate the effects of continuous positive airway pressure (CPAP) and bi-level positive airway pressure (BiPAP) on extravascular lung water during weaning from mechanical ventilation in patients following coronary artery bypass grafting. Design; Prospective, randomized clinical study. Setting; Intensive care unit at a university hospital. Patients; Seventy-five patients following coronary artery bypass grafting. Interventions; After extubation of the trachea, patients were treated for 30 min with CPAP via face mask (n=25), with nasal BiPAP (n=25), or with oxygen administration via nasal cannula combined with routine chest physiotherapy (RCP) for 10 min (n=25). Measurements and results: Extravascular lung water (EVLW), pulmonary blood volume index (PBVI) and cardiac index (CI) were obtained during mechanical ventilation (T1), T-piece breathing (T2), interventions (T3), spontaneous breathing 60 min (T4) and 90 min (T5) after extubation of the trachea using a combined dye-thermal dilution method. Changing from mechanical ventilation to T-piece breathing did not show any significant differences in EVLW between the three groups, but a significant increase in PBVI from 155±5 ml/m2 to 170±4 ml/m2 could be observed in all groups (p〈0.05). After extubation of the trachea and treatment with BiPAP, PBVI decreased significantly to 134±6 ml/m2 (p〈0.05). After treatment with CPAP or BiPAP, EVLW did not change significantly in these groups (5.5±0.3 ml/kg vs 5.0±0.4 ml/kg and 5.1±0.4 ml/kg vs 5.7±0.4 ml/kg). In the RCP-treated group, however, EVLW increased significantly from 5.8±0.3 ml/kg to 7.1±0.4 ml/kg (p〈0.05). Sixty and 90 min after extubation, EVLW stayed at a significantly higher level in the RCP-treated group (7.5±0.5 ml/kg and 7.4±0.5 ml/kg) than in the CPAP-(5.6±0.3 ml/kg and 5.9±0.4 ml/kg) or BiPAP-treated groups (5.2±0.4 ml/kg and 5.2±0.4 ml/kg). No significant differences in CI could be observed within the three groups during the time period from mechanical ventilation to 90 min after extubation of the trachea. Conclusions: Mask CPAP and nasal BiPAP after extubation of the trachea prevent the increase in extravascular lung water during x weaning from mechanical ventilation. This effect is seen for at least 1 h after the discontinuation of CPAP or BiPAP treatment.Further studies have to evaluate the clinical relevance of this phenomenon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...