Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 63 (1985), S. 711-717 
    ISSN: 1432-1440
    Keywords: Alpha-1-microglobulin ; Beta-2-microglobulin ; Proteinuria ; Renal insufficiency
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Alpha-1-microglobulin (alpha-1-m) is a low molecular weight glycoprotein (mw 25–33 KD) that is filtered through the glomeruli and reabsorbed in the proximal parts of the renal tubules where it is catabolized. Normal ranges were established for alpha-1-m (100 healthy controls) in serum (20–42 mg/l) and urine (3.5–8 mg/l). Alpha-1-m was then measured in 341 urine samples whose protein pattern had been classified as “pathologic” and “normal” according to microelectrophoresis. Increased alpha-1-m concentrations were found in 266 out of 280 pathologic urines (5% false negative) and in 3 out of 61 normal urines (4% false positive). Beta-2-microglobulin (beta-2-m), total protein or protein test strips showed a poorer correlation to the electrophoretic results. Measurement of alpha-1-m is, therefore, the most sensitive of these methods for the detection of proteinuria. In 90 patients with low molecular weight proteinuria and either with or without renal insufficiency alpha-1-m concentrations were determined in both urine and serum. While all patients had elevated urinary alpha-1-m concentrations, increased serum values were only found in renal insufficiency (Ccrea〈100 ml/min). Independently of these results, we were also able to establish that increased alpha-1-m levels are found at decreased glomerular filtration rates (Ccrea 〈70 ml/min). Pathologic alpha-1-m concentrations therefore only allow the conclusion of isolated tubular impairment when the GFR is greater than 70 ml/min. Data from 350 patients with various renal and hypertensive diseases showed that serum alpha-1-m is a more sensitive indicator of renal insufficiency, even in the so-called “creatinine blind” range (60–100 ml/min) of the GFR than either creatinine or beta-2-m.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Archives of gynecology and obstetrics 246 (1989), S. 97-105 
    ISSN: 1432-0711
    Keywords: Hypertensive pregnancy ; Proteinuria ; SDS-polyacrylamide gel electrophoresis ; Western blot ; Tamm-Horsfall glycoprotein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary By using of modified urine preparation and a highly sensitive SDS-polyacrylamide gel electrophoresis (SDS-PAGE) we determined the urinary protein profile in 21 healthy males, 25 healthy females, 64 patients with uncomplicated pregnancy and 110 hypertensive pregnant women. The urinary protein patterns were similar in controls and in women with a normal pregnancy. There were no increase in the number of protein bands from the 1st trimester to term, and the electrophoresis pattern did not change in the postpartum period. In both groups, an intensively stained protein band with an apparent molecular weight of 105 kD was detected. The 105 kD band was significantly reduced or completely absent in 91 (83%) out of 110 hypertensive pregnant women. The urinary protein electrophoresis profile correlated significantly with the severity of the disease. The 105 kD band disappeared just before or simultaneously with the onset of clinical symptoms in 18 out of 32 hypertensive pregnant women followed throughout pregnancy. Postpartum the 105 kD in urine reappeared at 2 to 14 days after delivery in 49 of the 53 patients. Using a silver staining and Western blot, the 105 kD band was identified as Tamm-Horsfall protein, which is identical to the immunosuppressive glycoprotein uromodulin. The findings in the SDS-PAGE may reflect a transitory tubular dysfunction in cases of pre-eclampsia, which is usually reversible after delivery. The results of our study support the hypothesis of an immunological basis for this disorder.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-0879
    Keywords: Proteinuria ; Kidney transplantation ; Kidney preservation ; HTK solution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Investigations were carried out by means of an autologous, heterotopic model for kidney transplantation applied to dogs. Duration of cold ischemia was 48 h. Four experimental groups were arranged. During the first 20 min following revitalization of the transplanted kidney, group 1 (HTK solution/80 cm perfusion height) showed a significant glomerular and tubular malfunction. In group 2 (HTK solution/120 cm perfusion height), only four urinary proteins with molecular weights of 25 kDa, 67 kDa, 100 kDa and 〉100 kDa were found. The excretion of higher molecular proteins receded over the 20-min period of observation. In both group 3 (HTK/aspartate solution) and group 4 (HTK/tryptophan solution) the quantity of excreted glomerular and tubular protein was well above that of group 2. As opposed to the “Tryptophan” group, a complete restoration of renal function was observed in the “Aspartate” group after 4 weeks. In general, the “standard” HTK protective solution delivered with 120 cm perfusion pressure gave the most favorable results, with the lowest levels of proteinuria and a satisfactory recovery of renal function after revitalization.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1434-601X
    Keywords: 21.10.Ft ; 25.70.Np ; 27.40.+z
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract At the projectile-fragment separator FRS of GSI, relativistic secondary beams of about 520 MeV/nucleon were produced by fragmentation of a primary beam of58Ni at 650 MeV/nucleon in a beryllium target. By means of aΔE—Bρ—TOF measurement, the fragments were identified and their charge-changing probabilities in targets of (CH2) n , C, Al, and Pb placed at the exit of the FRS were determined. Whereas a first article dealt with the total charge-changing cross sections, we describe in this second article the element distributions of these secondary fragments, which are found to depend strongly on the isospin of the secondary projectile as well as on the target material. In the case of the lead target, the influence of the electromagnetic dissociation is clearly visible in the one-proton and two-proton removal channels. The preference for the formation of even-Z fragments is much more pronounced for exotic secondary projectiles than for projectiles close to stability. Calculations with a geometrical abrasion-ablation model allow to understand the global features of the experimental data. However, far from stability, the discrepancies between calculations and experimental data increase.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1434-601X
    Keywords: 21.10.Ft ; 25.70.Np ; 27.40.+Z
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract At the projectile-fragment separator FRS of GSI, relativistic secondary beams of about 520 MeV/nucleon were produced by fragmentation of a primary beam of58Ni at 650 MeV/nucleon in a beryllium target. By means of aΔE—Bρ—TOF measurement, the fragments have been identified and their charge-changing probabilities in targets of CH2, C, Al, and Pb have been determined. We describe the results for the total charge-changing cross sections in this first paper, whereas a second article deals with the partial charge-changing cross sections. At the drip line, the measured charge-changing cross sections exhaust close to 100% of the total interaction cross sections as calculated with semiempirical models. The measurements at the proton drip line with low-Z targets indicate that only a very small increase of the cross sections may be observed, whereas the measurements with a lead target show that no significant increase of the total charge-changing cross sections is present which would be a hint for low-lying dipole strength. Our experimental data are compared to Glauber-type calculations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...