Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Recurrence  (1)
  • Septic puerperal ovarian vein thrombosis (SPOVT)—Computed tomography—Magnetic resonance angiography—Ultrasound.  (1)
Materialart
Erscheinungszeitraum
Schlagwörter
  • 1
    ISSN: 1432-1084
    Schlagwort(e): Key words: Ovarian cancer ; Lesion characterization ; Recurrence ; PET ; CT ; MRI
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. The aim of this study was to compare prospectively the accuracy of whole-body positron emission tomography (PET), CT and MRI in diagnosing primary and recurrent ovarian cancer. Nineteen patients (age range 23–76 years) were recruited with suspicious ovarian lesions at presentation (n = 8) or follow-up for recurrence (n = 11). All patients were scheduled for laparotomy and histological confirmation. Whole-body PET with FDG, contrast-enhanced spiral CT of the abdomen, including the pelvis, and MRI of the entire abdomen were performed. Each imaging study was evaluated separately. Imaging findings were correlated with histopathological diagnosis. The sensitivity, specificity and accuracy for lesion characterization in patients with suspicious ovarian lesions (n = 7) were, respectively: 100, 67 and 86 % for PET; 100, 67 and 86 % for CT; and 100, 100 and 100 % for MRI. For the diagnosis of recurrent disease (n = 10), PET had a sensitivity of 100 %, specificity of 50 % and accuracy of 90 %. The PET technique was the only technique which correctly identified a single transverse colon metastasis. Results for CT were 40, 50 and 43 %, and for MRI 86, 100 and 89 %, respectively. No statistically significant difference was seen. Neither FDG PET nor CT nor MRI can replace surgery in the detection of microscopic peritoneal disease. No statistically significant difference was observed for the investigated imaging modalities with regard to lesion characterization or detection of recurrent disease; thus, the methods are permissible alternatives. The PET technique, however, has the drawback of less accurate spatial assignment of small lesions compared with CT and MRI.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-0509
    Schlagwort(e): Septic puerperal ovarian vein thrombosis (SPOVT)—Computed tomography—Magnetic resonance angiography—Ultrasound.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Background: Septic puerperal ovarian vein thrombosis (SPOVT) is one of the underlying etiologies of puerperal fever. A correct diagnosis of this condition is important because adequate treatment requires additional administration of anticoagulants. The purpose of this study was to evaluate the role of duplex color Doppler ultrasound (CDUS), computed tomography (CT), and magnetic resonance angiography (MRA) in the detection of SPOVT. Methods: Twenty-six patients with puerperal fever suspected to be due to SPOVT and unresponsive to broad antibiotic treatment for at least 48 h were included in a prospective study using CDUS, CT, and MR imaging including MRA. Examinations were analyzed and then correlated to a standard of reference gathered from surgical and clinical follow-up data and from results of imaging. Results: SPOVT was present in nine patients (right side n = 8, bilateral n = 1). CDUS was inconclusive due to gaseous distention of the bowel or obesity in 13 of 26 cases. After counting inconclusive findings as wrong results for statistical purposes, sensitivity, specificity, and accuracy for CDUS were 55.6%, 41.2%, and 46.2%, respectively. CT had a sensitivity of 77.8% with a specificity of 62.5%; accuracy was 68.0%. MRA rendered conclusive results in all evaluated patients, resulting in a sensitivity and specificity of 100%. Conclusion: MRA is recommended in all patients with inconclusive CDUS findings and persistent suspicion for SPOVT. CT has the advantage of more rapid access and lower cost and thus will probably remain a sufficiently accurate alternative.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...