Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1573-0743
    Schlagwort(e): dobutamine stress echocardiography ; myocardial scintigraphy ; SPET ; Sestamibi ; pharmacological stress testing ; coronary artery disease
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Background: Simultaneous dobutamine stress echocardiography (DSE) and99mTc-MIBI-SPET (DMS) for the evaluation of the presence and the extent of coronary artery disease (CAD) were assessed for a head to head comparison regarding the diagnostic accuracy of the two tests. Methods and Results: Forty-five consecutive patients (33 males and 12 females: 53±6.8 yr.) underwent exercise electrocardiography and simultaneous dobutamine stress echocardiography and MIBI-SPET imaging. Coronary angiography was performed in all patients (significant coronary stenosis 〉 50%). On the basis of the results of exercise electrocardiogram the pre-test probability for coronary artery disease (Diamond's algorithm) was low (45.6±12.7 %). The overall specificity, sensitivity and predictive accuracy of Echo-dobutamine stress test for diagnosis of the presence or absence of CAD were: specificity 82%, sensitivity 76%, diagnostic accuracy 80%, positive predictive value 90%, negative predictive value 40%. The overall specificity, sensitivity and predictive accuracy of MIBI-SPET-dobutamine test for diagnosis of the presence or absence of CAD were: specificity 86%, sensitivity 87%, diagnostic accuracy 84%, positive predictive value 97%, negative predictive value 54%. MIBI-SPET-dobutamine test showed a significantly higher sensitivity in comparison with ECHO-dobutamine test (P〈0.05). Conclusion: Both noninvasive methods for the detection of CAD showed a good diagnostic accuracy. Nevertheless the SPET model showed an higher sensitivity in comparison with DSE model, essentially in the presence of a lower extent of CAD and during submaximal test.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1434-601X
    Schlagwort(e): 25.70-z ; 24.30.Cz ; 25.70.Lm
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract γ-rays are measured in coincidence with the dissipative complex fragments from the35Cl +64Ni reaction at 7.7 A MeV. Theoretical γ-ray coincidence spectra are determined through a fitting procedure using the contribution of the excited fragment statistical γ-decay calculated by means of the CASCADE code. Whereas the expected statistical spectra fit very well the data in the energy regionE ν=2 to 8 MeV, above this energy another emission mechanism in addition to the statistical decay has to be considered in order to reproduce the experimental spectra. Simulations based on the Vlasov equation suggest that this emission could come from the decay of dipole strength excited in the intermediate dinuclear system.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...