Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1990-1994  (2)
  • Naphthionate  (1)
  • Synthetic peptides  (1)
  • 1
    ISSN: 1432-0495
    Schlagwort(e): Groundwater ; Porous aquifer ; Heterogeneous ; Biological tracers ; Bacteriophage ; Fluorescent dye ; Naphthionate ; Electromagnetic survey
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Geologie und Paläontologie
    Notizen: Abstract This article presents an example of a tracing experiment using two bacteriophages, T7 and f1, and a fluorescent dye (naphthionate), in a saturated porous environment. The test field was equipped with an injection borehole and 22 sampling piezometers set in three concentric half-circles. The distribution of permeabilities and the thickness of the aquifer were indirectly determined by Radio-Magneto-Tellury (RMT, 12–240 kHz). The results reveal a good correlation between the distribution of permeabilities obtained by RMT and the breakthrough curves and speed of migration of all three tracers. The restitution levels are far superior (by two to three orders of magnitude) in the more permeable zones, as opposed to those observed in th piezometers situated in less permeable areas. The speed of migration of the biological tracers is much greater than that of the naphthionate. In the most extreme case, the T7 bacteriophage migrated about 3.15 times faster than the chemical solution. These results indicate that bacteriophages are able to travel considerable distances along permeable gravel channels. They may be used as biological tracers and as models for the migration of pathogenic viruses. The simultaneous use of tracing techniques and appropriate geophysical methods leads to a better knowledge of the hydrogeological parameters of the underground terrain. This combination allows for a better interpretation both of the speeds of migration and of the maximal concentrations of the tracers, and thus considerably increases the interpretability of hydrogeological impact studies.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1573-7284
    Schlagwort(e): HIV-1 ; Time-resolved fluoroimmunoassay ; Synthetic peptides
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract A simple, rapid, reproducible and sensitive peptide-Time-Resolved-Fluoroimmunoassay (TR-FIA) method is described which allows the detection of antibodies to the Human Immunodeficiency Virus type 1 (HIV-1). By using a panel of synthetic peptide antigens that covered env, gag and pol amino acid sequences, a 20 amino acid peptide (GIWGCSGKLICTTAVPWNAS) describing an immunodominant and conserved domain on the gp41 region of the BH10 clone was found to be the most reactive in this study. Optimal conditions for antigen concentration, serum dilution and incubation time were established. The peptide-TR-FIA is specific, as assessed by testing HIV-1 positive sera which included samples from AIDS, ARC patients and HIV-positive drug users. The test was used to detect HIV antibodies in 250 well characterized HIV-1 positive sera and 50 normal sera. Peptide-TR-FIA results indicate that the env peptide was highly reactive with HIV-positive sera showing a sensitivity of 100%. None of the 50 control sera showed positive reactivity against the synthetic peptide. Furthermore the peptide-TR-FIA allowed a fine titration of antibodies to defined epitopes of immunodominant HIV structural proteins that usually cannot be achieved by peptide-ELISA assays.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...