Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 5 (1984), S. 1039-1052 
    ISSN: 1572-9559
    Keywords: H2O laser ; Faraday rotation ; polarimetry ; far-infrared ; plasma diagnostics ; compact toroid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A fast response frequency-modulated interferometric polarimeter was designed and constructed with a single 28 μm H2O laser for high density plasma diagnostics. This newly developed modulation system employs an electro-magnetically driven movable mirror to achieve the modulation frequency beyound 1 MHz for about 100 μs duration. The movable mirror performance is studied experimentally in detail. The determination of the Faraday rotation angle is based on the zero-crossing method for the observed beat signals produced by two kinds of rotating plane-polarized waves. The feasibility of the polarimeter constructed was verified in experiments of a field-reversed thetapinch plasma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 2 (1981), S. 1199-1208 
    ISSN: 1572-9559
    Keywords: water vapor laser ; plasma diagnostics ; interferometer ; waveguide laser ; far-infrared
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A high-power CW 27.972 μm water vapor laser has been constructed in order to use as a light source of an interferometer for plasma diagnostics. The laser consists of 220 cm length and 2.0 cm small bore Pyrex glass discharge tube, semi-confocal resonator and Michelson coupler. From the measurement of cavity detuning curves, it is found that two waveguide modes, EH11 and EH21 oscillate. The increase of the output power is found to become more than seven times larger by adding He(50%)−H2(50%) mixed gas. Under the optimum condition, the maximum output power of 65 mW or the output power per unit cavity volume of 83 μW/cm3 is obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 4 (1983), S. 549-559 
    ISSN: 1572-9559
    Keywords: interferometer ; polarimeter ; water-vapor laser ; far-infrared ; plasma diagnostics ; compact toroid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A high-power CW 27.972 μm water-vapor laser has been developed for interferometric and polarimetric measurements of plasmas. The maximum output power and the power density in the cavity of the laser with 2.0 cm bore and 220 cm length reach 85 mW and 109 μW/cm3, respectively. An interferometer using this laser is constructed and its performance is examined as a study on polarimetric method of magnetic field measurement. Preliminary interferometric experiments are also carried out on a compact toroidal plasma with field-reversal configuration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 26 (1988), S. 641-646 
    ISSN: 1741-0444
    Keywords: Admittance plethysmography ; Arterial compliance ; Human limb ; Noninvasive measurement ; Volume elastic modulus ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Arterial elasticity expressed by such indices as volume elastic modulus Ev and compliance Ca were noninvasively measured in various human limb segments; the upper arms, forearms, fingers, thighs, calves and toes. These indices are defined, respectively, as $$E_v = \Delta P/(\Delta V/\bar V_a )$$ and Ca=ΔV/ΔP, where ΔP is pulse pressure, $$\bar V_a $$ mean arterial volume and ΔV its pulsatile variation. ΔP was calculated from systolic Pas and mean Pam arterial pressures determined by volume oscillometric sphygmomanometry using the following equation: $$\Delta P = 3(P_{as} - P_{am} )/2\bar V_a $$ and the ΔV were detected by electrical admittance plethysmography at various transmural pressure Pt levels controlled by a compression cuff. The values obtained in these limb segments were compared with each other at Pt levels 0,30 and 60 mm Hg and the differences between them were discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 549-554 
    ISSN: 1741-0444
    Keywords: Finger arterial pressure ; Indirect diastolic pressure ; Photoelectric plethysmography ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 27 (1989), S. 130-136 
    ISSN: 1741-0444
    Keywords: Diastolic pressure ; Finger arterial pressure ; Indirect sphygmomanometry ; Photoelectric plethysmography ; Pressure/volume relation ; Vibration method ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Diastolic pressure Pd was indirectly measured by vibrating a finger artery with a 10 Hz sinusoidal pressure variation during a gradual increase (or decrease) in occlusive cuff pressure Pc. Pulsatile arterial volume changes on which sinusoidal variations are superimposed were detected by a transmitted infra-red photoelectric plethysmograph (TIPP). It is known that volume change in an artery shows a maximum amplitude at the transmural pressure Pt level equal to 0 mm Hg due to the nonlinear viscoelastic properties of the arterial wall. For the same reason, the amplitude of the sinusoidal volume variation reached its maximum at the end-diastolic phase, when Pc was controlled to be exactly equal to Pd. The indirect Pd values determined from Pc were compared with those simultaneously measured by a direct method in rabbit forelegs and by the volume-compensation method in human fingers. Using the principle of the volume oscillometric method systolic and mean pressures were also determined by this system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...