Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 26 (1988), S. 641-646 
    ISSN: 1741-0444
    Keywords: Admittance plethysmography ; Arterial compliance ; Human limb ; Noninvasive measurement ; Volume elastic modulus ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Arterial elasticity expressed by such indices as volume elastic modulus Ev and compliance Ca were noninvasively measured in various human limb segments; the upper arms, forearms, fingers, thighs, calves and toes. These indices are defined, respectively, as $$E_v = \Delta P/(\Delta V/\bar V_a )$$ and Ca=ΔV/ΔP, where ΔP is pulse pressure, $$\bar V_a $$ mean arterial volume and ΔV its pulsatile variation. ΔP was calculated from systolic Pas and mean Pam arterial pressures determined by volume oscillometric sphygmomanometry using the following equation: $$\Delta P = 3(P_{as} - P_{am} )/2\bar V_a $$ and the ΔV were detected by electrical admittance plethysmography at various transmural pressure Pt levels controlled by a compression cuff. The values obtained in these limb segments were compared with each other at Pt levels 0,30 and 60 mm Hg and the differences between them were discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 549-554 
    ISSN: 1741-0444
    Keywords: Finger arterial pressure ; Indirect diastolic pressure ; Photoelectric plethysmography ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 27 (1989), S. 130-136 
    ISSN: 1741-0444
    Keywords: Diastolic pressure ; Finger arterial pressure ; Indirect sphygmomanometry ; Photoelectric plethysmography ; Pressure/volume relation ; Vibration method ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Diastolic pressure Pd was indirectly measured by vibrating a finger artery with a 10 Hz sinusoidal pressure variation during a gradual increase (or decrease) in occlusive cuff pressure Pc. Pulsatile arterial volume changes on which sinusoidal variations are superimposed were detected by a transmitted infra-red photoelectric plethysmograph (TIPP). It is known that volume change in an artery shows a maximum amplitude at the transmural pressure Pt level equal to 0 mm Hg due to the nonlinear viscoelastic properties of the arterial wall. For the same reason, the amplitude of the sinusoidal volume variation reached its maximum at the end-diastolic phase, when Pc was controlled to be exactly equal to Pd. The indirect Pd values determined from Pc were compared with those simultaneously measured by a direct method in rabbit forelegs and by the volume-compensation method in human fingers. Using the principle of the volume oscillometric method systolic and mean pressures were also determined by this system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...