Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel: DFG Deutsche Nationallizenzen  (2)
  • pharmacological stress testing  (1)
  • type 1 diabetes mellitus  (1)
  • 1
    ISSN: 1432-5233
    Schlagwort(e): Key words Sodium-hydrogen antiporter ; Echocardiography ; type 1 diabetes mellitus
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract We assessed the relationship between erythrocyte Na+/H+ antiport activity and myocardial anatomical-functional parameters (by Doppler echocardiography) in normotensive IDDM patients, with and without microalbuminuria. We studied 33 normotensive IDDM subjects and 14 matched healthy controls (group 4). Based on urinary albumin excretion rate (UAER), 23 diabetics were normoalbuminuric, 10 microalbuminuric (group 3). Normoalbuminurics were divided up for normal (group 1, n = 13) or high (group 2, n = 10) antiport activity. We evaluated fasting glycaemia and 24-h urine glucose output, HbA1c, plasma lipids, urea, creatinine and electrolyte clearances, UAER, erythrocyte Na+/H+ countertransport, M-Mode and 2D echocardiograms with Doppler analysis. Antiport, which was higher in diabetics than controls, was significantly overactive in groups 2 and 3 vs group 4, independently from UAER. Diabetics showed left ventricular volume, cardiac mass and systolic function within the control range. In left ventricular diastolic filling, while peak E was similar in diabetic and healthy people, the late peak transmitral flow velocity (peak A) was significantly higher in diabetics than controls, and this was also true in groups 2 and 3 vs group 4. Antiport activity was positively related to peak A (p〈0.03). These observations suggest that (a) the Na+/H+ antiport may be overactive in diabetes, apart from microalbuminuria; (b) increased Na+/H+ antiport activity, in normotensive IDDM people, may be associated with preclinical diastolic myocardial dysfunction (``incipient diabetic cardiomyopathy''?).
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1573-0743
    Schlagwort(e): dobutamine stress echocardiography ; myocardial scintigraphy ; SPET ; Sestamibi ; pharmacological stress testing ; coronary artery disease
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Background: Simultaneous dobutamine stress echocardiography (DSE) and99mTc-MIBI-SPET (DMS) for the evaluation of the presence and the extent of coronary artery disease (CAD) were assessed for a head to head comparison regarding the diagnostic accuracy of the two tests. Methods and Results: Forty-five consecutive patients (33 males and 12 females: 53±6.8 yr.) underwent exercise electrocardiography and simultaneous dobutamine stress echocardiography and MIBI-SPET imaging. Coronary angiography was performed in all patients (significant coronary stenosis 〉 50%). On the basis of the results of exercise electrocardiogram the pre-test probability for coronary artery disease (Diamond's algorithm) was low (45.6±12.7 %). The overall specificity, sensitivity and predictive accuracy of Echo-dobutamine stress test for diagnosis of the presence or absence of CAD were: specificity 82%, sensitivity 76%, diagnostic accuracy 80%, positive predictive value 90%, negative predictive value 40%. The overall specificity, sensitivity and predictive accuracy of MIBI-SPET-dobutamine test for diagnosis of the presence or absence of CAD were: specificity 86%, sensitivity 87%, diagnostic accuracy 84%, positive predictive value 97%, negative predictive value 54%. MIBI-SPET-dobutamine test showed a significantly higher sensitivity in comparison with ECHO-dobutamine test (P〈0.05). Conclusion: Both noninvasive methods for the detection of CAD showed a good diagnostic accuracy. Nevertheless the SPET model showed an higher sensitivity in comparison with DSE model, essentially in the presence of a lower extent of CAD and during submaximal test.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...