Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 1952-1955 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A CuO/MgO epitaxial artificially superstructured film [CuO(50 A(ring))/MgO(40 A(ring))]40 was successfully grown and its structure was studied by x-ray diffraction (XRD). The film was found to have a texture in which the (111) planes of monoclinic CuO and the (001) planes of cubic MgO were layered perpendicular to the film plane. Its lateral structure was revealed by precession photographs where the CuO [101¯] axis is oriented approximately along the MgO [100] axis in the film plane. The XRD pattern, observed over a wide range of scattering vectors perpendicular to the film plane, was carefully analyzed by an extended step model. The fluctuation of the superlattice period was estimated to be as small as 1 A(ring).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 77 (1995), S. 1189-1193 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Mössbauer spectra of 57Fe-doped polycrystalline CuO/Al2O3 multilayers (CAOs) show magnetic ordering at liquid helium temperature. The Néel temperature of a CAO with thin CuO layers is lower than that of bulk CuO judged from the temperature dependence of the Mössbauer spectra. A paramagnetic component was observed in all magnetic susceptibility measurements of the multilayers. The component also exists in both polycrystalline and epitaxial CuO/MgO multilayers. We have found that the component was localized at interfaces and derived from the spin fluctuation effect. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 70 (1991), S. 6241-6243 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The crystallization process and magnetic properties of Fe–P–C–Cu–Ge–Si amorphous alloys were investigated. After annealing above the crystallization temperature, the bcc Fe particles, with nanoscale grain size, precipitated in the amorphous alloy for a wide P concentration range. The volume ratio of the bcc Fe phase to amorphous was about 30%. The mixed phase of these alloys shows a drastic decrease of coercive force (Hc) and particle diameter (d) as P concentration increases. The lowest Hc was obtained for Fe78P16C2Cu0.5Ge3Si0.5, and Hc and d were 1.8 A/m and 16 nm, respectively. Observation by in situ Lorentz scanning electron microscopy (SEM) revealed that the width of magnetic domains were 0.01 or 0.1 mm and the domain walls with smaller bcc Fe particles moved in a weaker magnetic field than those with larger ones. So the low Hc is attributed to the decrease of magnetocrystalline anisotropy caused by fine structures. The core loss of fine crystalline Fe–P–C–Cu–Si–Mo alloy, W14/50, was 0.22 W/kg after annealing under a magnetic field of 2.4 kA/m.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Elastic and thermal properties of Au/Ni superlattices have been investigated by x-ray diffraction on a synchrotron radiation source at the Photon Factory. An elastic response of [Au(10 A(ring))/Ni(10 A(ring))]50 to hydrostatic pressure generated by a diamond anvil cell has been measured in the layer-stacking direction. Its compressibility obtained from the pressure dependence of its superlattice period (Λ vs P) shows an anomalously small value compared with either bulk Au or Ni metal. Linear thermal expansions has also been measured by a similar method (Λ vs T). A significant anisotropic behavior between the layer-stacking and in-plane direction was found in both [Au(10 A(ring))/Ni(10 A(ring))]50 and [Au(4 A(ring))/Ni(4 A(ring))]210.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 34 (1995), S. 2870-2874 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 59 (1991), S. 1401-1403 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A ZnSe/ZnSSe blue semiconductor laser was demonstrated to show very low threshold by direct photopumping of the ZnSe active layer. The lowest threshold at the excitation wavelength of 445 nm was 10 kW/cm2 at 300 K which is equivalent to the current density of 3.6 kA/cm2. This is the lowest threshold ever reported in II-VI photopumped lasers and is approaching the theoretically calculated threshold. The characteristic temperature of the threshold, which characterizes the temperature dependence of the threshold in the exponential form, was 124 K up to the measured 400 K and was comparable to III-V double-heterostructure lasers. The differential quantum efficiency remained the similar level up to 400 K and its decrease observed at 400 K was within 23% of the efficiency at 300 K.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The efficacy of granisetron, droperidol and metoclopramide for the prevention of postoperative nausea and vomiting in female patients undergoing middle ear surgery was compared. In a randomised, double-blind study, 180 patients received granisetron 40 μg.kg−1, droperidol 20 μg.kg−1 or metoclopramide 0.2 mg.kg−1 given intravenously immediately before induction of anaesthesia (n = 60 for each). A standardised general anaesthetic technique was employed throughout. A complete response, defined as no postoperative nausea and vomiting and no need for another rescue anti-emetic, during the first 3 h after anaesthesia was achieved in 83%, 58% and 55% of patients who had received granisetron, droperidol and metoclopramide, respectively. The corresponding incidence during the next 21 h after anaesthesia was 85%, 54% and 47% (p 〈 0.05). No clinically important adverse effects were observed in any of the groups. We conclude that prophylactic therapy with granisetron is superior to droperidol or metoclopramide in the prevention of postoperative nausea and vomiting after middle ear surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford : Blackwell Science Ltd
    Anaesthesia 54 (1999), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We investigated the accelographic train-of-four response evaluated at the great toe at varying stimulating currents. Fifteen adult patients undergoing elective general anaesthesia were studied. The mean current at which a supramaximal T1 value could be elicited was 〉 49 (9) mA [mean (SD)]. Ratios of accelographic T1 values at 50, 40, 30, 20 and 10 mA to accelographic T1 value at 60 mA were 0.90 (0.18), 0.58 (0.37), 0.38 (0.37), 0.19 (0.26) and 0.00 (0.00), respectively [mean (SD), p 〈 0.05 for 50 mA vs. 30, 20 and 10 mA, p 〈 0.05 for 40 mA vs. 20 and 10 mA, and p 〈 0.05 for 30 vs. 10 mA]. Threshold currents for train-of-four (the lowest currents at which any train-of-four response could be elicited) before and after induction of anaesthesia were 30 (10) and 31 (10) mA, respectively. The train-of-four ratio (T4/T1) measured at varying currents did not differ significantly. However, in the patients in whom threshold currents for train-of-four were 40, 30 and 20 mA, the train-of-four ratio recorded at the threshold current was significantly less than at 50 mA. We conclude that at the great toe, the mean current at which a supramaximal response to train-of-four can be yielded is as high as 〉 49 mA. The mean threshold currents for TOF before and after induction of anaesthesia were 30 and 31 mA, respectively. Train-of-four ratio measured at the threshold current is less than that at 50 mA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In order to obtain reliable data on d values and integrated intensities, an imaging plate (IP) has been applied to high-pressure diffraction experiments with a diamond anvil cell using synchrotron radiation. The IP was found to be more effective than a conventional x-ray film by a factor of 30, and more effective than an energy dispersive method by several times. In order to integrate the intensity data on the IP, a histogram method was successfully developed. This combination proved to give a lattice constant with relative accuracy of 2×10−4, and observed integrated intensities which excellently agree with calculated ones.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford : Blackwell Science Ltd
    Anaesthesia 53 (1998), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We have studied the recovery of post-tetanic count and train-of-four responses at the great toe and thumb accelerographically after the administration of vecuronium 0.2 mgkg−1. Sixty adult patients scheduled for anaesthesia with nitrous oxide and isoflurane were studied. The times to the return of the first post-tetanic twitch were comparable at the great toe and thumb (mean (SD) times: 30.0 (6.5) min and 35.0 (8.5) min, respectively). Recovery of post-tetanic count followed similar time courses at the great toe and thumb. Also, time to the return of the first twitch of the train-of-four did not differ significantly at the great toe and thumb (47.5 (9.6) min vs. 49.7 (10.5) min). Similarly, time to the return of the second, third and fourth twitches of the train-of-four did not significantly differ at the great toe and the thumb. However, the value of the first twitch of the train-of-four, expressed as a proportion of control twitch, was significantly higher than that at the thumb between 50 min and 110 min after the vecuronium injection, and the train-of-four ratio at the great toe was significantly higher than that at the thumb between 60 min and 100 min after the vecuronium injection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...