Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1432-1106
    Schlagwort(e): Early SEPs ; P16 ; Source analysis ; Human
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Following median nerve stimulation, several monophasic peaks were recorded at the scalp in the 15–18 ms time range. Source analysis, using three different methods, modelled a source near the centre of the head with an orientation towards the activated hemisphere and a peak activity at 16 ms post stimulus. Magnetic recordings detected no signal in this time range, which confirmed a subcortical location of the source. From dipole localization it was not possible to assign the exact origin of the P16 source to either the subthalamic level or the thalamo-cortical radiation, because of the limited spatial resolution at the centre of the spherical head model. An estimate of the conduction velocity of the medial lemniscus pointed towards a subthalamic origin. The P16 source was preserved in two patients with a lesion of the thalamo-cortical radiation and the ventral thalamus. Further evidence for a subthalamic location of P16 was derived from the physical mechanisms generating far-field potentials.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1573-6792
    Schlagwort(e): EEG/MEG ; Nonlinear dipole fit ; Simulated annealing ; Regularization ; Truncated singular value decomposition ; Finite element method
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The inverse problem arising from EEG and MEG is largely underdetermined. One strategy to alleviate this problem is the restriction to a limited number of point-like sources, the focal source model. Although the singular value decomposition of the spatio-temporal data gives an estimate of the minimal number of dipoles contributing to the measurement, the exact number is unknown in advance and noise complicates the reconstruction. Classical non-regularized nonlinear dipole fit algorithms do not give an estimate for the correct number because they are not stable with regard to an overestimation of this parameter. Too many sources may only describe noise but can still attain a large magnitude during the inverse procedure and may be indiscernible from the true sources. This paper describes a nonlinear dipole fit reconstruction algorithm with a new regularization approach for the embedded linear problem, automatically controlled by the noise in the data and the condition of the occuring least square problems. The algorithm is stable with regard to source components which “nearly” lie in the kernel of the projection or lead field operator and it thus gives an estimate of the unknown number parameter. EEG simulation studies in a simulated sulcus structure are carried out for an instantaneous dipole model and spatial resolution in the sulcus and stability of the new method are compared with a classical reconstruction algorithm without regularization.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...