Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1612-1112
    Schlagwort(e): Miniaturized HPLC ; Post-Column Extraction Detection ; Segmented-Flow Open-Tubular Reactors ; Membrane Phase Separator ; Anti-Cancer Drugs
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract An on-line, post-column, extraction system suitable for use with miniaturized HPLC (0.7–1 mm i.d. columns) is described. The system consists of a 30° angle segmenting tee, a PTFE extraction coil of variable length and a membrane phase separator. The internal volume of the phase separator is less than 1 μl. The total variance contribution of the system is between 1 and 6 sec2. The determination of the anti-cancer drugs VP 16 and VM 26 in urine by means of reversed-phase HPLC and fluorescence detection, using both on-column preconcentration and the present miniaturized post-column extraction system is presented as an application.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1612-1112
    Schlagwort(e): Liquid chromatography ; Photochemical reaction detection ; Chemical post-column reduction ; Fluorimetric detection ; Air segmented flow systems ; Non-aqueous reversed-phase chromatography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A new photochemical reaction method for the on-line fluorimetric detection of natural vitamin K homologs was developed. In addition to its high sensitivity, the method features an interesting selectivity for the determination of these compounds in a complex matrix such as human serum. The formation of different photolysis products as a function of reaction conditions, and the optimalisation of a segmented flow reaction system will be discussed. The results indicate that the method is 4 times more sensitive than UV detection, and at least as selective as fluorescence detection after post-column chemical reduction.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...