Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 21
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 306-307 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, LC ; Hydrophobic interaction chromatography, HIC ; Separation of proteins ; Type of salt ; TSKgel phenyl-5PW ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The combination of a high-performance liquid chromatograph and a magnetic type mass spectrometer with an atmospheric ionization source has been applied for analyses of thermolabile compounds, i.e. antibiotics, amino acids and glycosphingolipids.Chromatography was performed on a 4 mm i.d. x 150 mm column packed with 5 μm ODS at a flow rate of 1 ml min-1. The liquid chromatography/atmospheric pressure ionization (LC/API) magnetic-type mass spectrometer provides not only an abundant pseudo-molecular ion but also fragment ions which give a structural information resulting from collision-induced dissociation at the differential pumping region of the liquid chromatograph/mass spectrometer interface. The isomers of kanamycins could be differentiated from each other on the basis of their mass spectra obtained at the relatively higher drift voltage applied. LC/API mass spectra of leucine and isoleucine were very similar, but it was easy to differentiate one from another by checking the existence of the ions at m/z 43 or m/z 57 in their mass spectra. The LC/API mass spectra of glucosylceramides showed [MH]+ ions of good abundance and significant fragment ions useful for chemical characterization at a proper drift voltage setting in a controlled and reproducible manner.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Gamete Research 17 (1987), S. 15-20 
    ISSN: 0148-7280
    Keywords: nuclear transplantation ; electrofusion ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: The present study was undertaken to determine the efficiency of HVJ treatment and electrofusion for pronuclear transplantation in the mouse. The output voltage and duration of the pulses were fixed to 200 μsec at 10 V or to 150 μsec at 15 V for electrofusion, because the maximum rates of blastomere fusion of 2-cell embryos and development of fused embryos in vitro were obtained under these conditions. Although the proportion of eggs with fused karyoplast (78%) and the fused eggs developed to morulae or blastocysts (67%) was significantly lower than those obtained after HVJ treatment (94% and 94%), the proportion of pregnant recipients and young obtained after treatment of fused eggs was not significantly different between these two procedures.It is advised that electrofusion can be used as a fusogenic procedure for pronuclear transplantation in the mouse in some cases where HVJ cannot be applied.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...