Bibliothek

Sprache
Bevorzugter Suchindex
Ergebnisse pro Seite
Sortieren nach
Sortierung
Anzahl gespeicherter Suchen in der Suchhistorie
E-Mail-Adresse
Voreingestelltes Exportformat
Voreingestellte Zeichencodierung für Export
Anordnung der Filter
Maximale Anzahl angezeigter Filter
Autovervollständigung
Feed-Format
Anzahl der Ergebnisse pro Feed
feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Materialart
Erscheinungszeitraum
  • 1
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: 195 tritium ion source shots were injected into Tokamak Fusion Test Reactor (TFTR) high power plasmas during December 1993–March 1994. In addition, four highly diagnosed pulses were fired into the calorimeter. Analysis of the Doppler shifted Tα emission of the beam in the neutralizer has revealed that the extracted ion compositions for deuterium and tritium are indistinguishable: 0.72±0.04 D+; 0.22±0.02 D+2; 0.07±0.01 D+3 compared to 0.72±0.04 T+; 0.23±0.02 T+2; 0.05±0.01 T+3. The resultant tritium full-energy neutral fraction is higher than for deuterium due to the increased neutralization efficiency at lower velocity. To conserve tritium, it was used only for injection and a few calorimeter test shots, never for ion source conditioning. When used, the gas species were switched to tritium only for the shot in question. This resulted in an approximately 2% deuterium contamination of the tritium beam and vice versa for the first deuterium pulse following tritium. Data from the calorimeter shots indicate that tritium contamination of the deuterium beam cleans up in five to six beam pulses, and is reduced to immeasurable quantities prior to deuterium beam injection. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 130-138 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Analysis of Doppler-shifted Balmer-α line emission from the Tokamak Fusion Test Reactor's (TFTR) neutral beam injection systems has revealed that the line shape, which is a direct measure of the velocity distribution function, is well approximated by the sum of two Gaussians, or, alternatively, by a Lorentzian. For the sum of two Gaussians, the wide-divergence part of the distribution contains 40% of the beam power and has a divergence five times that of the narrow part. Assuming a narrow 1/e-divergence of 1.3° (based on fits to the beam shape on the calorimeter), the wide part has a divergence of 6.9°. The entire line shape is also well approximated by a Lorentzian with a half-maximum divergence of 0.9°. Up to now, most fusion neutral beam modelers have assumed a single Gaussian velocity distribution, at the extraction plane, in each direction perpendicular to beam propagation. This predicts a beam transmission efficiency from the ion source to the calorimeter of 97%. Waterflow calorimetry data, however, yield a transmission efficiency of ∼75%, a value in rough agreement with predictions of the two Gaussian or Lorentzian models presented here. The broad wing of the two Gaussian distribution also accurately predicts the loss in the neutralizer. An additional factor in determining the power density at the surface of beam absorbers is the angle at which the particles arrive. Angles are different for particles emitted from different locations on the ion source. To treat this situation, the average angle of incidence is calculated. For beam loss at the exit of the neutralizer, the average angle of incidence is 2.2°, rather than the 4.95° subtended by the center of the ion source. This average angle of incidence is found to be a function of beam divergence. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...