Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 540-543 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe an instrument designed to monitor molecular motions in multiphasic, weakly fluorescent microscopic systems. It combines synchrotron radiation, a low irradiance polarized microfluorimeter, and an automated, multiframing, single-photon-counting data acquisition system, and is capable of continually accumulating subnanosecond resolved anisotropy decays with a real-time resolution of about 60 s. The instrument has initially been built to monitor ligand–receptor interactions in living cells, but can equally be applied to the continual measurement of any dynamic process involving fluorescent molecules, that occurs over a time scale from a few minutes to several hours. As a particularly demanding demonstration of its capabilities, we have used it to monitor the environmental constraints imposed on the peptide hormone epidermal growth factor during its endocytosis and recycling to the cell surface in live cells. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 3716-3721 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe an instrument based on the novel combination of synchrotron radiation, a high sensitivity time-resolved microfluorimeter, and a multiframe single photon counting data acquisition system. This instrument has been designed specifically to measure kinetic events in live cells using fluorescence resonance energy transfer, and is capable of rapidly collecting multiple consecutive decay profiles from a small number of fluorophores. The low irradiance on the samples (〈10 mW/cm2) greatly reduces probe photobleaching and specimen photodamage during prolonged exposures. The Daresbury Synchrotron Radiation Source provides fully wavelength tunable light pulses that have a full width half-maximum of 160 ps at a repetition rate of 3.125 MHz, with the high temporal stability required for continuous measurements over periods of hours. A very low limit of detection (〈104 molecules/mW/cm2) is accomplished by combining a high-gain single photon counting detection system with a low fluorescence background optical layout. The latter is achieved by the inclusion of collimating optics, a reflecting objective, and a specially designed beam stop situated in the epi-fluorescence light-path. A typical irradiance of 8 mW/cm2 on a sample of ∼105 fluorescein molecules gives, in under 20 s, a fluorescence decay profile with a peak height of 104 counts, over 400 channels, and a signal to background ratio better than 40. The data acquisition system has been developed to have a real-time time-resolved fluorescence collection capability (denoted as TR2) so that fluorescence lifetime data can be continually collected throughout a changing process. To illustrate the potential of this instrument, we present the results of a TR2 experiment in which lifetime measurements of fluorescence resonance energy transfer are used to monitor the degree of clustering of epidermal growth factor receptors during endocytosis, over a period of about 1 h, with a 5 s resolution. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 87 (2000), S. 5711-5713 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: This work describes an experimental study which reviews the various techniques that can be used for determination of anisotropy fields in recording media. At the present time this topic is of considerable importance due to the need to understand the detailed mechanisms of magnetization reversal and the factors that control the switching field distribution in recording media. We have used a metal-particle-based tape material and have employed various magnetic techniques for the determination of the apparent anisotropy field, HK. The techniques included hysteresis loops measured in a direction transverse to the texture direction of the tapes, single-point detection in the successive derivatives of the magnetization with respect to the field, transverse susceptibility measurement, and the variation of the bulk coercivity with temperature. We find the temperature variation of coercivity produces values of HK far smaller than values determined by other methods due to orientation effects. General agreement is seen for the other techniques mentioned and results for samples with differing degrees of texture show that the apparent anisotropy field of the grains as measured by these techniques is influenced greatly by orientation effects. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The optical properties of a confocal scanning microscope that was designed to utilize a synchrotron as light source are presented. The usable spectral range is from 200 nm up to 700 nm. Using 325-nm laser light, it is shown that the lateral resolution is about 125 nm, and the axial resolution better than 250 nm. After transport of the microscope from Utrecht to the Daresbury Synchrotron Source, 200-nm excitation can be applied, and the lateral resolution will drop to below 100 nm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary. Circulating levels of four specific placental proteins, human chorionic gonadotrophin (hCG), Schwangerschafts protein 1 (SP1), placental protein 5 (PP5) and pregnancy-associated plasma protein A (PAPP-A), were measured in 31 patients with hydatidiform mole before treatment. Seven patients subsequently developed clinical chorio-carcinoma and three of them had pulmonary metastases. The estimations of hCG, PP5 and PAPP-A levels were found to be of no value in the prediction of malignant sequelae. Levels of SP1≥ 16.5 i.u./l were associated with a higher incidence of subsequent malignant disease (P 〈 0.05), the risk being at least nine times greater in these patients. The predictive value of high levels of SP1 was 35%, the specificity 45.8% and sensitivity 100%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 96 (1974), S. 43-48 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 13 (1974), S. 1071-1074 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 11 (1972), S. 1124-1127 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1365-2761
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Biology , Medicine
    Notes: Flavobacterium psychrophilum, the causative agent of bacterial coldwater disease (CWD) and rainbow trout fry syndrome (RTFS), causes high mortality in cultured salmonids. The present study was designed to determine the role antibody plays in conferring protection to rainbow trout fry, Oncorhynchus mykiss (Walbaum), by passive immunization with convalescent serum or serum from adult rainbow trout immunized with F. psychrophilum, and goat anti-F. psychrophilum serum. In each experiment, rainbow trout fry were injected intraperitoneally with antiserum and challenged by subcutaneous injection with a virulent strain (CSF-259-93) of F. psychrophilum 24-h post-immunization. Relative percentage survival (RPS) ranged from 9–42% when rainbow trout fry (mean weight 1.3 g) were injected with a 1:2 dilution of 25 μL of convalescent serum ranging in enzyme-linked immunosorbent assay antibody titres from 1600–102 400. Rainbow trout fry (mean weight 1.0 g) passively immunized with 25 μL of serum from immunized adult fish exhibited RPS values of up to 57%. In each of these experiments, RPS increased with increasing antibody titres against F. psychrophilum. Passive immunization with 25 or 50 μL goat anti-F. psychrophilum serum, however, did not confer protection to fry (mean weight 1.3 g). These results suggest that trout antibody plays a role in conferring protection to F. psychrophilum, but antibody alone is unable to provide complete protection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...