Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Materialart
Erscheinungszeitraum
  • 1
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A beamline for macromolecular crystallography has been designed for the ALS. The source will be a 37-pole wiggler with a 2-T on-axis peak field. The wiggler will illuminate three beamlines, each accepting 3 mrad of horizontal aperture. The central beamline will primarily be used for multiple-wavelength anomalous dispersion measurements in the wavelength range from 4 to 0.9 A(ring). The beamline optics will comprise a double-crystal monochromator with a collimating premirror and a double-focusing mirror after the monochromator. The two side stations will be used for fixed-wavelength experiments within the wavelength range from 1.5 to 0.95 A(ring). The optics will consist of a conventional vertically focusing cylindrical mirror followed by an asymmetrically cut curved-crystal monochromator. This paper presents details of the optimization of the wiggler source for crystallography, gives a description of the beamline configuration, and discusses the reasons for the choices made. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The radiation from the 5 cm period undulator at the Advanced Light Source (ALS) has been characterized using a transmission grating spectrometer. Spectral and angular distributions of radiation were measured for deflection parameter K values between 0.45 and 2.12 at low storage ring current (0.1–0.5 mA). From the calibration of the spectrometer, the absolute flux density of the undulator harmonics has been determined together with the spectral linewidth. The electron-beam emittance was determined by analyzing the angular distribution of the redshifted fundamental. Comparison has been made with radiation calculations based upon the measured magnetic-field data of the undulator. Including field errors, electron-beam emittance, and energy spread, good agreement is found between theoretically and experimentally determined harmonic widths and peak brightness. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 3368-3368 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The design and operation of an imaging beamline at the Advanced Light Source used for providing diagnostic information on the electron beam for the accelerator and experimental groups is described. This system is based on a Kirkpatrick-Baez mirror pair and utilizes a carbon filter to give a bandpass in the soft x-ray region. The focused x-rays are viewed on a single-crystal scintillator through an optical microscope and the image recorded on a CCD camera. This system, together with other instruments to evaluate beam size, stability, and other time-dependent information, is described, data are presented, and the operation of the overall beamline is evaluated. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 1514-1517 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The modeling of the optical properties of the acceleration field and objective lens of a photoemission electron microscope (PEEM) is presented. Theory to calculate the aberrations of the extraction field was derived, and extended to include relativistic effects. An analysis of the microscope's electron optical performance and aberrations has been performed using an analytical model as well as a ray tracing method. Ray tracing has the flexibility needed for the assessment of aberrations where the geometry is too complex for analytical methods. This work shows that in the case of a simple PEEM front end of the acceleration gap and objective lens, the all orders ray tracing and full analytical treatments agree to very high precision. This allows us now to use the ray tracing method in situations where analytical methods are difficult, such as an aberration compensating electron mirror. © 2002 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A smart pixel detector is being developed for time-resolved crystallography for biological and material science applications. Using the pixel detector presented here, the Laue method will enable the study of the evolution of structural changes that occur within a protein as a function of time. The x-ray pixellated detector is assembled to the integrated circuit through a bump bonding process. Within a pixel size of 150×150 mm2, a low-noise preamplifier-shaper, a discriminator, a 3-bit counter and the readout logic are integrated. The readout, based on the column architecture principle, will accept hit rates above 5×108/cm2/s with a maximum hit rate per pixel of 1 MHz. This detector will allow time-resolved Laue crystallography to be performed in a frameless operation mode, without dead time. Target specifications, architecture, and preliminary results on a 8×8 prototype are presented. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 1480-1482 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Using a newly developed reflectometer we have measured the reflectivity at the silicon K edge for different silicon compounds. Combining these measurements with silicon L edge reflectivity measurements carried out on a different reflectometer we determined the binding energy of core excitons at the L edge. The results show that it is possible to carry out reflectivity measurements with the resolution necessary for the determination of the exciton parameters. Comparison with literature values shows that a rigid Kramers–Kronig analysis is not needed when the angle of incidence is well below the critical angle of total external reflection. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 1313-1316 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The design and performance of the undulator beamline 5U.1 at the SRS used for soft x-ray spectroscopy is reported and compared with the theoretical expectation of the intensity, resolution, and polarization. The beamline consists of a ten-period permanent magnet variable gap undulator followed by an entrance slitless plane grating monochromator. The energy region covered is from 0.1 to 1 keV. The design is similar to the SX700 but uses a spherical instead of an ellipsoidal focusing mirror. To eliminate the large horizontal beam width at the exit slit the beamline has been modified to include a post-focusing mirror. The spherical focusing mirror has been changed to one with a larger radius resulting in a decreased demagnification, thereby essentially eliminating primary coma. The monochromator contains an ion-etched and lamellar profile 1200-lines/mm plane grating of Pt-coated CVD SiC on a graphite substrate. The high flux of the undulator makes the beam line suitable for SEXAFS studies and for work involving soft x-ray fluorescence detection. The combination of high flux and high resolution is especially advantageous for atomic and molecular spectroscopy and to resolve the quasiatomic structures which are observed in localized 3d transition metal compounds.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 1482-1485 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: We report on an environmental chamber, which is attached to a UHV beamline, in which soft x-ray measurements can be done at atmospheric pressure in helium. X-ray measurements in air can only be performed at energies above about 3 keV because of the strong absorption of soft x rays by oxygen and nitrogen. However, a low-Z scatterer such as helium has a long absorption length for soft x rays even at atmospheric pressure. Thus, this new chamber allows soft x-ray experiments to be performed on samples with physical properties that are incompatible with UHV conditions, e.g., liquid and frozen aqueous solutions, corrosive materials, etc. A helium-tight tank has been installed behind the vacuum experimental chamber of the double crystal beamline 3.4 at the Daresbury SRS. The tank is purged with helium at atmospheric pressure and the gas in the tank is isolated from the high vacuum of the rest of the beamline by a thin mylar window which is supported on a capillary array. The tank contains a sample stage, two ionization chambers and a parallel-plate gas proportional counter for fluorescence detection of dilute samples, which has produced good results on the K edges of Cl, S, and P.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: In this article we report the characteristics of the new High Energy Spherical Grating Monochromator beam line on the SRS. The instrument, which has no entrance slit, was designed to provide high photon flux with small spot size, in the energy range covering the 1s binding energies of carbon, nitrogen, oxygen, and fluorine. Radiation from a bending magnet is horizontally focused onto the exit slit by a long, Pt-coated meridian cylinder (R=299 m, 2 mrad horiz. aperture, 2° glancing angle). The light is vertically diffracted and focused by one of three interchangeable spherical gratings (1050, 1500, and 1800 lines mm−1) operating in negative order. Finally, the light is refocused by an ellipsoidal mirror. The photon flux, determined with copper and carbon photocathodes, is presented for the three gratings. Useful flux is obtained in the range 250–1200 eV, with intensity maxima for each grating at 600, 700, and 800 eV of 11, 9, and 5×1010 photons s−1 per 100-mA stored beam into a band pass of 0.05%. The influence of contaminants which are present on the optical elements is discussed, together with details of beam line operating conditions which minimize the build up of such contaminants. Photoabsorption and photoemission measurements indicate a high (up to 30%) second order and some third order light content. Resolution determinations obtained from photoabsorption measurements are presented. Although features as narrow as 250 meV have been resolved, the resolving power of the instrument is found to depend strongly on stored beam current. We suggest this may be due to electron beam (i.e., source) blow-up. We critically discuss the suitability of the new facility for surface EXAFS of low Z adsorbates, in particular above the carbon, nitrogen, and oxygen 1s edges, using examples from recent studies which have been undertaken on the beamline.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The availability of high brilliance third generation synchrotron sources together with progress in achromatic focusing optics allows us to add submicron spatial resolution to the conventional century-old x-ray diffraction technique. The new capabilities include the possibility to map in situ, grain orientations, crystalline phase distribution, and full strain/stress tensors at a very local level, by combining white and monochromatic x-ray microbeam diffraction. This is particularly relevant for high technology industry where the understanding of material properties at a microstructural level becomes increasingly important. After describing the latest advances in the submicron x-ray diffraction techniques at the Advanced Light Source, we will give some examples of its application in material science for the measurement of strain/stress in metallic thin films and interconnects. Its use in the field of environmental science will also be discussed. © 2002 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...