Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The arrangement of spins at interfaces in a layered magnetic material often has an important effect on the properties of the material. One example of this is the directional coupling between the spins in an antiferromagnet and those in an adjacent ferromagnet, an effect first discovered ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 1608-1615 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The development of high-resolution, grazing-incidence soft x-ray monochromators is discussed, and the performance of competing designs is reviewed in terms of efficiency, ultimate resolution, and order sorting. In particular, the characteristics of astigmatically corrected spherical grating monochromator systems (SGM) is examined. A new design is presented in which a variable angle premirror is used to eliminate the wavelength dependent image distance of the SGM and allows the use of order sorting ranges. The properties of a competing design using a plane variable angle premirror, plane grating, and spherical mirror combination are presented, and similarities between this and the corrected SGM are discussed. Flux and resolution data are presented for an undulator monochromator of this latter design.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 1313-1316 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design and performance of the undulator beamline 5U.1 at the SRS used for soft x-ray spectroscopy is reported and compared with the theoretical expectation of the intensity, resolution, and polarization. The beamline consists of a ten-period permanent magnet variable gap undulator followed by an entrance slitless plane grating monochromator. The energy region covered is from 0.1 to 1 keV. The design is similar to the SX700 but uses a spherical instead of an ellipsoidal focusing mirror. To eliminate the large horizontal beam width at the exit slit the beamline has been modified to include a post-focusing mirror. The spherical focusing mirror has been changed to one with a larger radius resulting in a decreased demagnification, thereby essentially eliminating primary coma. The monochromator contains an ion-etched and lamellar profile 1200-lines/mm plane grating of Pt-coated CVD SiC on a graphite substrate. The high flux of the undulator makes the beam line suitable for SEXAFS studies and for work involving soft x-ray fluorescence detection. The combination of high flux and high resolution is especially advantageous for atomic and molecular spectroscopy and to resolve the quasiatomic structures which are observed in localized 3d transition metal compounds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The double-crystal monochromator on beam line 3.4 at the Daresbury synchrotron radiation source covers the energy region 0.8–4 keV, routinely using crystal pairs of beryl, quartz, InSb, Ge, and Si. The beam line has a unique system to cut off high-energy radiation. The whole beam line has been built on a swinging arm, which allows the glancing angle on a chromium coated premirror to be varied between 0.5° and 3°. This not only reduces the heat load on fragile crystals, but also reduces the higher order contributions. We have made a thorough study of the alignment problems arising in the double-crystal geometry. Crystal misalignment, Bragg angular offset, as well as heat-load effects, can cause severe beam movements. A beam-position monitor, which has recently been commissioned, is an invaluable diagnostic tool for these beam movements.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A vertically dispersing high-energy spherical grating monochromator (HESGM) has been installed on the synchrotron radiation source (SRS) at the Daresbury Laboratory. The instrument has no entrance slit and provides a high intensity source of x rays of energy 250–1400 eV focused into a small spot suitable for surface spectroscopy. Photoabsorption features of 240 meV have been resolved, but the resolution of the instrument is dependent on the SRS stored beam current. The degree of linear polarization has been measured at the carbon K edge to be 0.80.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In this article we report the characteristics of the new High Energy Spherical Grating Monochromator beam line on the SRS. The instrument, which has no entrance slit, was designed to provide high photon flux with small spot size, in the energy range covering the 1s binding energies of carbon, nitrogen, oxygen, and fluorine. Radiation from a bending magnet is horizontally focused onto the exit slit by a long, Pt-coated meridian cylinder (R=299 m, 2 mrad horiz. aperture, 2° glancing angle). The light is vertically diffracted and focused by one of three interchangeable spherical gratings (1050, 1500, and 1800 lines mm−1) operating in negative order. Finally, the light is refocused by an ellipsoidal mirror. The photon flux, determined with copper and carbon photocathodes, is presented for the three gratings. Useful flux is obtained in the range 250–1200 eV, with intensity maxima for each grating at 600, 700, and 800 eV of 11, 9, and 5×1010 photons s−1 per 100-mA stored beam into a band pass of 0.05%. The influence of contaminants which are present on the optical elements is discussed, together with details of beam line operating conditions which minimize the build up of such contaminants. Photoabsorption and photoemission measurements indicate a high (up to 30%) second order and some third order light content. Resolution determinations obtained from photoabsorption measurements are presented. Although features as narrow as 250 meV have been resolved, the resolving power of the instrument is found to depend strongly on stored beam current. We suggest this may be due to electron beam (i.e., source) blow-up. We critically discuss the suitability of the new facility for surface EXAFS of low Z adsorbates, in particular above the carbon, nitrogen, and oxygen 1s edges, using examples from recent studies which have been undertaken on the beamline.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 3368-3368 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design and operation of an imaging beamline at the Advanced Light Source used for providing diagnostic information on the electron beam for the accelerator and experimental groups is described. This system is based on a Kirkpatrick-Baez mirror pair and utilizes a carbon filter to give a bandpass in the soft x-ray region. The focused x-rays are viewed on a single-crystal scintillator through an optical microscope and the image recorded on a CCD camera. This system, together with other instruments to evaluate beam size, stability, and other time-dependent information, is described, data are presented, and the operation of the overall beamline is evaluated. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 1480-1482 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Using a newly developed reflectometer we have measured the reflectivity at the silicon K edge for different silicon compounds. Combining these measurements with silicon L edge reflectivity measurements carried out on a different reflectometer we determined the binding energy of core excitons at the L edge. The results show that it is possible to carry out reflectivity measurements with the resolution necessary for the determination of the exciton parameters. Comparison with literature values shows that a rigid Kramers–Kronig analysis is not needed when the angle of incidence is well below the critical angle of total external reflection. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The radiation from the 5 cm period undulator at the Advanced Light Source (ALS) has been characterized using a transmission grating spectrometer. Spectral and angular distributions of radiation were measured for deflection parameter K values between 0.45 and 2.12 at low storage ring current (0.1–0.5 mA). From the calibration of the spectrometer, the absolute flux density of the undulator harmonics has been determined together with the spectral linewidth. The electron-beam emittance was determined by analyzing the angular distribution of the redshifted fundamental. Comparison has been made with radiation calculations based upon the measured magnetic-field data of the undulator. Including field errors, electron-beam emittance, and energy spread, good agreement is found between theoretically and experimentally determined harmonic widths and peak brightness. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A beamline for macromolecular crystallography has been designed for the ALS. The source will be a 37-pole wiggler with a 2-T on-axis peak field. The wiggler will illuminate three beamlines, each accepting 3 mrad of horizontal aperture. The central beamline will primarily be used for multiple-wavelength anomalous dispersion measurements in the wavelength range from 4 to 0.9 A(ring). The beamline optics will comprise a double-crystal monochromator with a collimating premirror and a double-focusing mirror after the monochromator. The two side stations will be used for fixed-wavelength experiments within the wavelength range from 1.5 to 0.95 A(ring). The optics will consist of a conventional vertically focusing cylindrical mirror followed by an asymmetrically cut curved-crystal monochromator. This paper presents details of the optimization of the wiggler source for crystallography, gives a description of the beamline configuration, and discusses the reasons for the choices made. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...