    Bioprocess and biosystems engineering 6 (1991), S. 213-219 
    ISSN: 1432-0797
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract A perfusion system for production of monoclonal antibodies was developed using an externally-mounted, hollow-fibre cartridge. The experimental apparatus was operated for 420 h and demonstrated increased steady-state viable cell concentration with increase in perfusion rate. Antibody titres were up to three times those measured for batch cultures and specific antibody productivity was doubled. The procedure was successfully scaled to a 10 dm3 system which produced antibody under conditions of Good Manufacturing Practice (GMP). A calculation of productivity between the scaled perfusion system and 260 dm3 batch cultures resulted in comparable antibody production, whereas the perfusion allowed a halving in medium utilisation. Reactivity assays conducted on the purified antibody from both batch and perfusion cultures showed no evidence of proteolysis or altered antibody activity in the final perfusion product. This study provides additional support for the use of homogeneous perfusion cultures in production of monoclonal antibodies under GMP conditions.