Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (11)
  • Osteoporosis  (4)
  • cis-unsaturated fatty acid  (4)
  • Systemic lupus erythematosus  (3)
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Chemistry and Physics of Lipids 66 (1993), S. 209-214 
    ISSN: 0009-3084
    Keywords: Fatty acid mixture ; Miscibility ; Phase diagram ; Polymorphism, DSC ; cis-unsaturated fatty acid
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0009-3084
    Keywords: asclepic acid ; cis-unsaturated fatty acid ; crucic acid ; high-pressure ; polymorphic transformation
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Chemistry and Physics of Lipids 63 (1992), S. 243-250 
    ISSN: 0009-3084
    Keywords: DSC ; cis-unsaturated fatty acid ; fatty acid mixture ; miscibility ; phase diagram ; polymorphism
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Chemistry and Physics of Lipids 56 (1990), S. 59-63 
    ISSN: 0009-3084
    Keywords: DSC ; cis-unsaturated fatty acid ; high-pressure DTA ; palmitoleic acid ; polymorphic transformation ; pressure effect
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1437-160X
    Keywords: Systemic lupus erythematosus ; Fever ; Serum globulin fractions ; Discriminant analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In an attempt to find a reliable method to assess fever in patients with systemic lupus erythematosus (SLE), a multifactorial analysis was applied to the routine laboratory examinations, including white blood cell count (WBC) and serum globulin fraction concentrations. During 74 febrile episodes, 49 SLE patients showed increased disease activity and the remaining 25 febrile episodes were due to intercurrent infection. The two different groups of fever episodes were clearly separated by a principal component analysis using five variables from the routine laboratory tests, including WBC, serum alpha-1, alpha-2, beta, and gamma globulins. Discriminant analysis showed that 95% of 74 febrile episodes could be correctly classified as to the cause of fever when a combination of WBC and alpha-2 globulin level was used as variables. A simple discriminant formula which we calculated was considered to be of practical use for the differentiation of the two clinical entities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1437-160X
    Keywords: U1-ribonucleoprotein ; Immune complexes ; Mixed connective tissue disease ; Systemic lupus erythematosus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We measured U1-RNP: anti-U1-RNP immune complexes (U1-RNP ICs) in patients with mixed connective tissue disease (MCTD) and systemic lupus erythematosus (SLE) to examine the clinical significance of circulating U1-RNP ICs. The level of U1-RNP ICs in 11 patients with MCTD was significantly higher than that in 22 normal subjects and there was a close correlation between the level of U1-RNP ICs and the clinical disease activity index of MCTD. In contrast, the level of U1-RNP ICs in 31 patients with SLE was not significantly higher than that in normal subjects and that was not correlated with the clinical disease activity index of SLE or the renal histologic activity index of lupus nephritis. We conclude that U1-RNP ICs are present in sera of patients with MCTD and SLE, and that the level of U1-RNP ICs may be closely associated with clinical disease activity in patients with MCTD.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Rheumatology international 8 (1989), S. 273-277 
    ISSN: 1437-160X
    Keywords: Plasminogen activation ; Plasmin ; α2-Plasmin inhibitor ; Complements ; Systemic lupus erythematosus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We measured α2-plasmin inhibitor-plasmin complexes (PI-PC) in plasma of patients with systemic lupus erythematosus (SLE) to examine the plasminogen activation in SLE. The plasma PI-PC level in 23 patients with SLE was significantly higher than that in 18 normal subjects (P〈0.001) and the SLE patients with nephrotic syndrome had higher plasma PI-PC levels than those without nephrotic syndrome (P〈0.01). In addition, the plasma PI-PC level was significantly correlated with the level of plasma C3 breakdown products (iC3b/C3dg) in the patients with SLE (r=0.53, P〈0.01). These results suggest that plasminogen is activated in plasma of patients with SLE and that the plasminogen activation may be associated with the activation of complement in SLE.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Osteoporosis international 4 (1994), S. 220-225 
    ISSN: 1433-2965
    Keywords: Calcaneus ; Dual X-ray absorptiometry ; Menopause ; Osteoporosis ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The velocity (SOS), attenuation slope (BUA) and stiffness index in the os calcis were measured using the ‘Achilles’ ultrasound bone densitometer (Lunar, Madison, WI). We evaluated the basic attributes of this ultrasound bone densitometer, and showed the age-related changes in ultrasound values in normal Japanese women. The precision was measured in vivo on ten occasions over a 2-week period in 5 subjects. The short-term precision errors (CVs) in vivo were 0.6% for stiffness index, 0.3% for SOS and 1.0% for BUA. Spine, femur neck and total body BMD using dual X-ray absorptiometry (DXA) were highly correlated with stiffness index (r=0.80, 0.77 and 0.78, respectively) in 194 subjects. Ultrasound values for patients with osteoporosis were significantly lower than those for the normal controls. TheZ-score compared with young normals was significantly higher for spine bone mineral density (−4.4) than for stiffness index (−3.5); BUA and SOS gave significantly lowerZ-scores −2.9 and −3.0, respectively). Ultrasound values were also lower compared with age-matched normal controls. TheZ-score for stiffness index (−2.1) was significantly superior to that for either SOS or BUA (−1.5). Age-related change in ultrasound values was evaluated in 842 normal women. There was a decline in stiffness index of about 24% from the values in young adulthood to those of women in their seventies, about 75% of which occurred from age 44–49 years onward. These findings seem to indicate that the menopause affected the change in ultrasound values. In conclusion, ultrasound bone densitometry may not be as useful as DXA of the spine for screening for osteoporosis, since theZ-score for DXA is excellent. However, ultrasound bone densitometry appears potentially to be applicable to problems in the diagnosis and management of osteoporosis when used in association with DXA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Osteoporosis international 7 (1997), S. 195-199 
    ISSN: 1433-2965
    Keywords: Bone mineral density ; Osteoporosis ; Quantitative computed tomography ; Radius
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The present study evaluated a commercial device for peripheral quantitative computed tomography (pQCT) and examined the age-related changes in normal Japanese women. The volumetric bone mineral density (vBMD) of the distal radius [integral bone mineral density (BMDI), trabecular bone mineral density (BMDT) and cortical with subcortical bone mineral density (BMDSC)] was measured using pQCT (Norland-Stratec XCT960) in 617 healthy women aged 20–79 years and 75 subjects with osteoporosis aged 60–89 years who exhibited at least one vertebral fracture. The short-term precision errors in vivo (CV, %) were 1.1% for BMDI 1.1% for BMDT and 1.2% for BMDSC. The correlations between pQCT and dual-energy X-ray absorptiometry measurements (Lunar DPX) of the lumbar spine werer∼0.8 (BMDI, BMDT and BMDSC). The maximal mean vBMD values were observed between 20 and 49 years; BMDI BMDT and BMDSC all showed a linear postmenopausal decline averaging 1.1% per year. The overall decreases in vBMD from the peak values in those 70–79 years were 34%, 32% and 33% in BMDI, BMDT and BMDSC, respectively. The diagnostic sensitivity of osteoporosis was expressed as aT-score.T-scores using pQCT were −3.0 (BMDI), −2.4 (BMDT) and −2.9 (BMDSC). Bone mineral measurement of the distal radius may be useful in the evaluation of age-related bone loss and for the diagnosis of osteoporosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 55 (1994), S. 324-329 
    ISSN: 1432-0827
    Keywords: Photodensitometry ; Radiogrammetry ; Metacarpal bone ; Bone mineral density ; Osteoporosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract The metacarpal bone mineral density (BMD) and metacarpal index (MCI) of the second metacarpal bone were measured by computed X-ray densitometry (CXD) (Teijin Ltd., Tokyo), which we have established with the development of microdensitometry of radiographs. In this study, we evaluated the basic attributes of this CXD method and determined the age-related changes in both metacarpal measurements in normal Japanese women. The precision in vivo was measured in eight subjects. The precision errors [coefficient of variation (CV)] were 0.2–1.2% CV for metacarpal BMD and 0.4–2.0% CV for MCI, respectively. We have obtained low precision error and more rapid analysis, within 3 minutes respectively, compared with the previous methods. Age-related changes in the metacarpal measurements were evaluated in 1438 normal women. Both measurements showed the most significant decrease in the sixth decade of life. The rate of decrease in the sixth decade was 1.6%/year for metacarpal BMD and 1.5%/year for MCI. On comparison between metacarpal BMD by CXD and spine BMD using dual energy X-ray absorptiometry (DXA) in 248 normal women with and without menstruation, the two measurements were found to be similarly decreased in the subjects within 5 years after menopause. There was also no significant difference in the Z-score between metacarpal BMD and spine BMD within 5 years after menopause. These results indicate that early postmenopausal bone loss occurs not only in the spine but also in the metacarpal bone. The metacarpal BMD for patients with osteoporosis was significantly lower than that for age-matched normal controls, although the Z-score for spine BMD (-1.46) was significantly better than that for metacarpal BMD (-0.82). In conclusion, because CXD has excellent low precision error and is widely available at relatively low cost, it appears potentially to be applicable to problems in the diagnosis and management of osteoporosis, when used in association with DXA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...