Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2005-2009
  • 1955-1959  (8)
  • 1958  (2)
  • 1956  (6)
Material
Years
  • 2005-2009
  • 1955-1959  (8)
Year
  • 1
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 178 (1956), S. 1122-1123 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] A number of authors have studied the incorporation of methionine (sulphur-35) into the central nervous system3-7. In agreement with their work, it has been demonstrated that a relatively larger amount of methionine (sulphur-35) is incorporated into the grey matter of brain and spinal cord than into ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 353-361 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Flame photometry, an excellent micromethod particularly for mixtures of alkalis, demands the most careful consideration of the influence of cosolutes (partners) if quantitative data are demanded. In addition to secondary interferences (foreign light, alteration of the atomizing conditions) which are readily eliminated, real interferences occur because of the influence of dissociation and ionization in the flame. The great influence of the temperature and the concentration of the solution on the error arising from the cosolutes is discussed.
    Abstract: Résumé La photométrie de flamme est une excellente microméthode, particulièrement pour les mélanges d'alcalis; mais elle demande une étude très soignée de l'influence des autres substances dissoutes si l'on désire obtenir des données quantitatives précises. En plus d'interférences secondaires (lumière parasite, modification des conditions de vaporisation) qui sont aisément éliminées, des interférences réelles proviennent de la dissociation et de l'ionisation dans la flamme. On discute l'influence importante de la température et de la concentration de la solution sur l'erreur correspondant à l'influence des corps dissouts.
    Notes: Zusammenfassung Die Flammenspektrometrie— eine ausgezeichnete Mikromethode insbesondere für Gemische von Alkalien — erfordert bei quantitativen Aussagen die sorgfältige Berücksichtigung des Einflusses der Lösungsgenossen (Partner). Neben sekundären Störungen (Fremdlicht, Änderung der Zerstäubungsbedingungen), die sich weitgehend ausschalten lassen, treten durch Beeinflussung der Dissoziation und Ionisation in der Flamme echte Störungen auf. Es wird der große Einfluß der Temperatur und der Lösungskonzentration auf die durch Partner bedingten Fehler behandelt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 42 (1956), S. 286-299 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The present communication deals with the results obtained by studying the incorporation of meth-ionine-35S into the affected nerve cells. In a previous investigation3, it was found that methionine-85S becomes incorporated to a larger extent in the grey matter than in the white matter, and this is ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 36 (1958), S. 20-22 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zusammenfassung Mittelwerte und Streuung der AHG-Aktivität stimmen bei Knaben und Mädchen überein. Hiermit ist die Hypothese, nach der die normale Streuung der AHG-Aktivität durch eine X-chromosomale Allelenreihe bedingt wäre, unvereinbar. Konduktorinnen des Hämophilie-Gens zeigen wahrscheinlich eine leichte Verminderung der AHG-Aktivität. Diese Beobachtung spricht dafür, daß bei der Hämophilie nicht allein ein Mangel an AHG vorliegt, sondern ein funktionell minderwertiges Gen-Produkt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 284 (1956), S. 749-750 
    ISSN: 1435-2451
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 149 (1956), S. 29-40 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung 1. Die bei der alkalimetrischen Gesamtphosphorsäurebestimmung metall-ionenhaltiger Lösungen infolge von Phosphatfällungen auftretenden Komplikationen lassen sich durch einen Zusatz von Kaliumoxalat — das als Komplexbildner oder als Fällungsmittel dient — ausschalten. Es gelingt dabei, eine Genauigkeit von ± 0,4% zu erreichen. 2. Die bei den Metallphosphatfällungen freiwerdenden H+-Ionen gestatten einen Rückschluß auf die Zusammensetzung der Niederschläge und ermöglichen auch die Bestimmung des Metallgehalts der Lösungen. Diese Bestimmungen sind mit einer Genauigkeit von etwa ± 10% durchzuführen. 3. Bei der Verwendung von Dimethylgelb und Phenolphthalein als Indicatoren bei der Titration metall-ionenhaltiger Phosphorsäure — andere Indicatoren und Indicatormischungen sind von unterschiedlicher Brauchbarkeit — kann bei Einhaltung bestimmter Arbeitsbedingungen eine zunächst nicht zu erwartende Genauigkeit von ± 3% erreicht werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 152 (1956), S. 56-76 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...