Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2005-2009
  • 1975-1979  (3)
  • Analytical Chemistry and Spectroscopy  (2)
  • Erdnußagglutinin  (1)
  • 1
    ISSN: 1432-1440
    Keywords: Thomsen-Friedenreich Antigen ; Erdnußagglutinin ; Neuraminidase ; Autoradiographie ; Fluorescenzmikroskop ie ; Thomsen-Friedenreich antigen ; Peanut agglutinin ; Neuraminidase ; Autoradiography ; Fluorescence microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary 1. Three different methods are described for the visualisation of the Thomsen-Friedenreich (TF) antigen on cell suspensions, formalin-fixed and paraffin embedded or frozen tissue sections: a) Rosette formation with chicken and sheep erythrocytes. b) Fluorescence-microscopy with fluorescein labelled peanut agglutinin. c) Autoradiography with3H-labelled peanut agglutinin. 2. The TF antigen was shown, as far as presently investigated, to be exposed on various blood cells, glomerula of the kidney and normal mammary gland after neuraminidase treatment. Mammary gland was also shown to possess TF receptors without prior treatment with neuraminidase. 3. The exposure of this cryptantigen can be brought about by bacterial or viral neuraminidase and is followed by an antigen/antibody reaction, which can lead to possible pathological consequences.
    Notes: Zusammenfassung 1. Drei verschiedene Methoden zur Darstellung von sog. Thomsen-Friedenreich (TF)-Antigenen in Zellsuspensionen, an Formalin-fixiertem und in Paraffin eingebettetem Gewebe sowie in Gefrierschnitten werden beschrieben: a) Rosetten-Bildung mit Hühner- und Schaferythrocyten. b) Fluorescenzmikroskopie mit Fluorescein-markiertem Erdnußagglutinin. c) Autoradiographie mit3H-markiertem Erdnußagglutinin. 2. Nach Neuraminidasebehandlung konnten TF-Antigene — soweit bisher untersucht — auf verschiedenen Blutzellen, in Nierenglomerula und in normalem Brustdrüsengewebe nachgewiesen werden. Ein Teil derartiger Antigene lag im Brustdrüsenparenchym auch bereits als freie Rezeptoren vor, d. h. waren nicht von Neuraminsäure bedeckt. 3. Die Freilegung dieser Kryptantigene kann im Rahmen von Infektionen durch bakterielle und virale Neuraminidase erfolgen. Dabei kommt es zu einer Antigen/Antikörper Reaktion mit unter Umständen klinisch relevanten Folgen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Breath tests that measure the oxidative utilization of 13C labeled substrates have been shown to be clinically useful, but have failed to gain wide acceptance because of the slow and costly isotopic analysis of the breath samples. Therefore we have developed a fully automated, microprocessor controlled CO2 purification and isotopic analysis system. The breath CO2 is cryogenically purified by passage through cold traps of -94°C and -196°C to condense water and CO2, respectively. The CO2 is introduced into a dual inlet, peak-stepping mass spectrometer and analyzed for isotopic content by comparison with a known standard. Thirty samples can be analyzed without operator intervention. Analysis time averages 14 minutes per sample, and the analysis has a precision of 0.3‰ which corresponds to 3 parts excess 13C per 106 parts CO2. The speed of analysis is comparable with scintillation counting and permits next day reporting of clinical breath test results. The precision is sufficient for clinical applications as it is less than the 0.7‰ isotopic variation in basal breath CO2.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 5 (1978), S. 29-31 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simplified technique of collecting breath CO2 for isotopic analysis has been developed. The subject breathes into a 3 I bag from which a 50 ml aliquot is transferred to an evacuated, septum-capped tube (Vacutainer®). The sample is later withdrawn and the CO2 is cryogenically purified. No isotope fractionation is observed in samples collected in this manner. Samples have been stored up to three months without any change in the isotope ratio.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...