Library

Your search history is empty.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 20 (1933), S. 51-55 
    ISSN: 1437-1596
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 18 (1932), S. 254-256 
    ISSN: 1437-1596
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 23 (1934), S. 126-131 
    ISSN: 1437-1596
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 18 (1932), S. 42-45 
    ISSN: 1437-1596
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Archives of toxicology 16 (1957), S. 230-232 
    ISSN: 1432-0738
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zusammenfassung Es wird der klinische Verlauf einer akuten Diphenylhydantoinvergiftung bei einem 2jährigen Kinde geschildert. Es trat vollständige Wiederherstellung ein.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of cancer research and clinical oncology 60 (1955), S. 408-418 
    ISSN: 1432-1335
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zusammenfassung 4989 Carcinomfälle unter 25147 Sektionen der Jahre 1920–1953 werden hinsichtlich ihrer Verteilung auf Luiker und Nichtluiker nach Häufigkeit, Organlokalisation, Alter und Geschlecht eingehend statistisch bearbeitet. 1. Unter den Luikern findet sich eine signifikant geringere Häufigkeit des Carcinoms (12,7%) als bei den Nichtluikern (20,2%). 2. Organverteilung und Alterszusammensetzung der Carcinome bei Lues unterscheiden sich nicht grundsätzlich von der der Nichtluiker und der Carcinome insgesamt. Das Geschlechtsverhältnis dagegen weicht mit einer stärkeren Beteiligung der Männer (1,5∶1) von dem der Nichtluikercarcinome ab (1∶1,1) und entspricht genau dem der Gesamtluesfälle. 3. Nur eine einzige, dem Umfang nach kleine Sektionsstatistik zur Untersuchung der Frage des Zusammentreffens von Lues und Carcinom liegt in der Literatur vor; sie kommt zu einem ähnlichen Ergebnis wie wir. Die Fälle der zahlreichen, einschlägigen, ganz vorwiegend klinischen und kasuistischen Veröffentlichungen, die meist für einen krebsbegünstigenden Einfluß der Lues eintreten, sind einseitig ausgewählt und bei kritischer Durchsicht nach statistischen Gesichtspunkten in ihren Relationen nicht auf die personelle Gesamtheit übertragbar. 4. Bisher bestehen weder für eine kanzerogene noch für eine krebsverhütende Wirkung der Lues eindeutige theoretische oder experimentelle Grundlagen. 5. Die statistischen Ergebnisse geben zunächst keinen genügenden Anhalt für einen direkten Zusammenhang zwischen Lues und Carcinom. Ob tatsächlich das Carcinom bei Luikern etwas seltener vorkommt als bei Nichtluikern, bedarf erst noch der Bestätigung durch weitere vielfältige entsprechende Erhebungen an großem Material. Sicher aber könnte dafür nicht die geringere Lebensdauer der Luiker verantwortlich gemacht werden, die sie das durchschnittliche Krebsalter nicht erreichen ließe; denn Luiker ohne und mit Carcinom zeigen die gleiche Altersverteilung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Russian chemical bulletin 7 (1958), S. 1372-1377 
    ISSN: 1573-9171
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary 1. In admixture with tert-butylmethoxyphenol, ascorbyl palmitate effectively retards air-oxidation processes in rendered animal fats. 2. Replacement of palmitic acid by a mixture of synthetic fatty acids (C14-C16 fraction) in the preparation of ascorbic esters does not affect their antioxidant properties deleteriously. 3. The effectiveness of a mixture of 0.01% of tert-butylmethoxyphenol and 0.02%) ascorbyl palmitate as an antioxidant for rendered animal fats does not depend on the temperature of oxidation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1608-3245
    Keywords: DNA ; kinetics ; oligonucleotide derivatives ; photomodification ; sensitization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Quantitative characteristics of thermodynamic and kinetic cooperativity arising in the process of photomodification of a single-stranded DNA fragment with binary systems of oligonucleotide conjugates forming an active site on the target were studied. Oligonucleotides of the binary system were complementary to adjacent segments of the DNA target, and contained arylazide (X) and perylene (S) residues covalently attached to their terminal phosphates. Upon irradiation at the perylene absorption wavelength, the target was modified by the arylazide residue, which was activated owing to the contiguity with the sensitizing perylene group in the tandem complex. Basing on the kinetic data, the constants of association of both derivatives of oligonucleotides with the target were determined: K x = 1.13 · 106 M–1, K s = 1.49 · 104 M–1. It was determined that association of both oligonucleotides with the target proceeded with a positive cooperativity characterized by parameter α = 45. The kinetic cooperativity parameter β was found to be approximately equal to 200; this characterized the acceleration of target modification in complex with the binary reagent versus that in the absence of sensitizer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1435-1544
    Keywords: Key words Heart rate variability – 24-h ambulatory Holter ECG –¶recording technology – validation ; Schlüsselwörter Herzfrequenzvariabilität – Langzeit-EKG –¶Holter-Rekorder – Validierung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Hintergrund: In Laboruntersuchungen wurde anhand eines computergenerierten, starrfrequenten EKG-Signals die Überlegenheit der digitalen gegenüber der analogen Aufzeichnungstechnologie in der zeitlichen Akquisitionsgenauigkeit der R-R-Intervalle, als rechnerischer Ausgangsgröße aller Verfahren der HRV-Analyse, belegt. Bandsystemen sind demnach Akquisitionsungenauigkeiten immanent, die eine technisch bedingte, höhere künstliche Variabilität erzeugen.¶   Zielstellung und Methodik: Da die Absolutwerte der künstlichen Variabilität im Vergleich zu den allgemein akzeptierten HRV- Normwerten jedoch vergleichsweise gering ausfallen, sollte die klinische Bedeutung der Ergebnisse aus dem Labor untersucht werden. Dazu wurden analoge Magnetband (A)- und digitale (D) Langzeit-EKG-Rekorder der Firma Ela medical unter Verwendung derselben Elektroden parallelgeschaltet und 24-Stunden-Registrierungen an Patienten mit einer Herzerkrankung und Sinusrhythmus vorgenommen. Unter gleichen Analyse- und Auswertebedingungen lassen sich dann Einflüsse unterschiedlicher Akquisitionsgenauigkeiten über die Differenz zwischen analoger und digitaler Aufzeichungstechnologie für Indizes der Zeit- und der Frequenzdomäne erfassen.¶   Ergebnisse: Die Analyse der Parallelregistrierungen an 20 Patienten ergab bei den gemittelten Werten statistisch signifikante positive Analog-Digital-Differenzen für die Indizes SDNN-Index (A: 38,47ms; D: 36,17ms; p=0,003), RMSSD (A: 25,04ms; D: 21,09ms; p 〈0,001), pNN50 (A: 3,70%; D: 2,40%; p=0,006), Total power (A: 1200,20ms2; D: 1076,55ms2; p=0,032), LF (A: 287,35ms2; D: 243,80ms2; p=0,035), HF (A: 72,50ms2; D: 54,95ms2; p=0,001) sowie signifikant negative A-D-Differenzen für die LF/HF ratio (A: 4,47; D: 5,33; p=0,037). Für SDNN (A: 95,59ms; D: 94,74ms; p=0,29) und SDANN (A: 85,52ms; D: 85,08ms; p=0,68) waren die Unterschiede nicht signifikant.¶   Schlussfolgerungen: Damit ist belegt, dass auch unter klinischen Bedingungen aus Bandregistrierungen künstlich höhere Variabilitäten bestimmt werden. Allerdings muss auch festgestellt werden, dass die Differenzen für die Indizes der Zeitdomäne zwischen Analog- und Digitalregistrierung eher geringer ausfallen als in den Laborversuchen mit computergeneriertem EKG und die Absolutwerte der Differenzen der HRV-Indizes in Relation zur Variationsbreite der Normwerte wenig bedeutsam sind. Somit hat die Wahl der Aufzeichnungstechnologie der Holter-EKG-Systeme für die Bestimmung der HRV im klinischen Alltag nur geringe Bedeutung. Bei der Durchführung von Studien und Betreuung von Hochrisikopatienten ist jedoch die Auswahl der Rekordertechnik kritisch zu überdenken und die digitale Aufzeichnungstechnologie grundsätzlich zu bevorzugen.
    Notes: Summary The accuracy of the RR interval data acquisition is an essential prerequisite for reliable analysis of heart rate variability (HRV). In previous laboratory investigations, in which computerized electrocardiograms were simultaneously sampled at identical heart rates using digital and analog tape recorders, the superiority of the digital recorders was clearly demonstrated. Conventional tape recordings exhibit technical variability which may produce false positive HRV results. However, the clinical significance of this type of variability is not known.¶   Aim of the study: To characterize the clinical relevance of technical RR variability related to the conventional tape recording process.¶   Methods: In 20 patients with cardiac disease and stable sinus rhythm, 24-hour Holter monitoring was performed by connecting each patient simultaneously to a conventional tape and a digital Holter recorder (Ela medical) via the same leads. Technical variability was defined as the difference between the HRV results obtained by the respective analog (A) and digital (D) recording methods.¶   Results: For the following HRV indices significant A-D differences were found: SDNNindex: 38.47ms (A) vs. 36.17ms, p=0.003; RMSSD: 25.04ms (A) vs. 21.09ms (D), p〈0.001; pNN50: 3.70% (A) vs. 2.40% (D), p=0.006; Total power: 1200.20ms2 (A) vs. 1076.55ms2 (D), p=0.032; LF power: 287.35ms2 (A) vs. 243.80ms2 (D), p=0.035; HF power: 72.50ms2 (A) vs. 54.95ms2 (D); p=0.001, and the LF/HF ratio: 4.47 (A) vs. 5.33 (D), p=0.037. No significant differenes were found for the following indices: SDNN: 95.59ms (A) vs. 94.74ms (D), p=0.29; and SDANN: 85.52ms (A) vs. 85.08ms (D), p=0.68.¶   Conclusions: Under both experimental and clinical conditions, higher HRV values were found in the conventional (tape) recordings. However, the technical variability was small in comparison with the mean values of normal HRV indices and their standard deviation. Thus, differences due to different recorder technology may be neglected in clinical practice. Nevertheless, in scientific HRV trials, it seems wise to use digital Holter recorders.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...