Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (157)
  • 1985-1989  (177)
  • 1965-1969  (51)
  • 1915-1919  (9)
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 92 (1988), S. 5366-5370 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 2499-2503 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe the design and characterization of a new variable low-temperature scanning tunneling microscope (STM) which has been proven to give atomic resolution at temperatures between 77 K and room temperature but which is also capable of performing experiments as low as 4 K. The STM "head'' itself consists of a unique cold dewar made up of an upper and lower reservoir connected together by two tubes which pass through an 8 in. conflat flange. The STM stage is suspended in between the two reservoirs by three long springs which pass through holes in the upper reservoir and also attach to the top flange. An adjustable cold shroud surrounds the STM stage for radiation shielding while allowing sample and tip transfer when raised. It has the additional advantage of providing a controllable heat leak. By raising the shroud, the temperature can be increased; by lowering it, the temperature can be decreased. The cold reservoirs can be filled with either liquid nitrogen or liquid helium. In the case of liquid helium, an additional liquid nitrogen "jacket'' surrounds the STM head. Everything is operated inside a customized ultrahigh vacuum chamber containing low-energy electron diffraction and various sample preparation facilities. A detailed description of the STM is presented together with performance results. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Following the success of solid state detector systems for extended x-ray absorption fine structure studies at high x-ray energies, there is now an increasing demand for similar devices capable of operating in the soft x-ray energy range below about 3 keV. Recent developments in sophisticated detector fabrication techniques now make the construction of specialized devices, suitable for high quality spectroscopy in this energy range, a practicable proposition. We present the results of extensive testing of a new detector developed specifically for use in the sub-3 keV energy range. We have measured energy resolutions of less than 125 eV full width at half maximum at sulfur and silicon Kα energies and the ability of the detector to achieve this resolution at the copper Lα line has also been shown. Finally we demonstrate the potential of this device in a study of trace dopants in bulk silicon based quantum dot glasses. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Reduction of indigenous metal impurities in tokamak plasmas and impurity requirements for the x-ray diagnosis of central plasma parameters necessitates artificial introduction of metal atoms. A new inexpensive method is described using ferrocene, Fe(C5H5)2, a substance which sublimes. A prototype device was tested at the Atomic-Beam Facility at PPPL. Ferrocene was injected into a pulsed helium plasma with an electron density of 2×1013 cm−3 and an electron temperature of 5 eV. The injected amount of ferrocene was controlled by varying the sublimation temperature in the range from 70 to 150 °C and adjusting the pulse length of a solenoid valve; the resulting iron atom concentration in the plasma was determined by monitoring the intensity of the Fe line at 5269 A(ring). The device and the test results are presented. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: High-resolution measurements of the He-like Kr K-shell radiation are presented showing the direct excitation lines as well as Li- and Be-like dielectronic recombination lines appearing in the KLL resonance. The measurements were performed on the Electron Beam Ion Trap (EBIT) facility and motivated by the need for accurate atomic data of high-Z He-like K-shell transitions for diagnostic applications in determining the central ion and electron temperature of very-high-temperature plasmas produced in next-generation tokamaks, such as the International Thermonuclear Experimental Reactor (ITER). © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    The @photogrammetric record 6 (1969), S. 0 
    ISSN: 1477-9730
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying
    Notes: The problem of incorporating airborne auxiliary data into an aerial triangulation block adjustment is considered. The conclusion is reached that this problem can be most readily solved by the use of a fully rigorous adjustment method. The first order adjustment equations for all types of airborne auxiliary control are developed and the method of incorporating these equations into the block solution is demonstrated. The general computing problems of the aerial triangulation block adjustment are briefly discussed and a method outlined for the incorporation of tie strips, at any angle across the block, into the adjustment without unduly increasing the storage requirements for the solution. The problem of correctly weighting the different types of available data is discussed. The paper concludes with a demonstration of the improved accuracy possible if precise aerial triangulation data are combined with apparently crude absolute airborne data.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    The @photogrammetric record 5 (1965), S. 0 
    ISSN: 1477-9730
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying
    Notes: Four authors review the activities of the seven Commissions of the I.S.P. at the Xth International Congress, Lisbon, 1964.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    The @photogrammetric record 5 (1965), S. 0 
    ISSN: 1477-9730
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying
    Notes: It does not seem to be widely recognised that the solution of the space resection problem from measurements made on a single photograph of three ground control points is not unique. There are, in general, four solutions, so that either the camera orientation must be approximately known (as is the case for near vertical photography) or extra control must be used to discriminate between these solutions. The iterative solution commonly used will only yield one solution, which will be correct if the photography is nearly vertical, but which is liable to be wrong in the general case. An explicit solution is therefore preferred since all solutions may be examined in the light of such extra control as is available. This paper gives a method for such a solution and shows how the discrimination should be used. The paper goes on to derive a method of adjusting the result to redundant control by least squares.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    The @photogrammetric record 12 (1987), S. 0 
    ISSN: 1477-9730
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of neurochemistry 46 (1986), S. 0 
    ISSN: 1471-4159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The effects of electroconvulsive shock on the levels of acetylcholinesterase in several brain regions of the rat were studied. Hippocampus, mesencephalon, cortex, and striatum exhibited rapid changes in acetylcholinesterase activity during the first few minutes following the convulsion, whereas brainstem and basal forebrain levels remained unchanged. In both hippocampus and midbrain there was a sustained decrease in activity: the total acetylcholinesterase activity was decreased by up to 40% within 2 min of the convulsion and did not return to control values for another 3 h. Thirty minutes after a flurothyl-induced convulsion there was a similar fall in acetylcholinesterase activity in both these regions, whereas a subconvulsive electric shock produced no change. It is concluded that a convulsion produces significant short-term decreases in acetylcholinesterase activity in areas of the rat brain that are involved in the generation and propagation of seizures, and the question is raised of whether this is related to the increase in seizure threshold that follows a convulsion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...