Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (419)
  • 1900-1904
  • Theoretical, Physical and Computational Chemistry  (228)
  • Computed tomography  (191)
Material
Years
Year
  • 1
    ISSN: 1432-1238
    Keywords: Key words A-mode ultrasonography ; Computed tomography ; Maxillary sinusitis ; Frontal sinusitis ; Mechanically ventilated patients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To study the accuracy of A-mode ultrasonography (A-MU) in detecting secretion in maxillary and frontal sinuses in critically ill, intubated patients undergoing mechanical ventilation. Design: Open study in mechanically ventilated, comatose patients. Setting: Medical-surgical intensive care unit in the General Hospital of Rovigo. Patients: 50 consecutive, mechanically ventilated, critically ill patients. All patients were in a coma and needed cerebral computed tomography (CT) for a diagnosis. Measurements and results: The A-MU technique gave 100 images of maxillary and frontal sinuses. The images were read blindly and classified into five categories: definitely normal, definitely abnormal, probably normal, questionable, and probably abnormal. CT findings were considered to be the „gold standard”. The specificity of echo images varied from 72 to 98% and the sensitivity from 63 to 86% for maxillary sinuses. For frontal sinuses, the specificity varied from 96 to 99% and the sensitivity from 14 to 57%. The area under the receiver-operating characteristic curve was found to be 0.89 and 0.76 for maxillary and frontal sinuses, respectively. Conclusions: The A-MU technique is an accurate tool for detecting secretion in the maxillary sinuses in intubated patients. More investigations are necessary in order to evaluate its usefulness in the frontal sinuses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: A-mode ultrasonography ; Computed tomography ; Maxillary sinusitis ; Frontal sinusitis ; Mechanically ventilated patients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To study the accuracy of A-mode ultrasonography (A-MU) in detecting secretion in maxillary and frontal sinuses in critically ill, intubated patients undergoing mechanical ventilation. Design Open study in mechanically ventilated, comatose patients. Setting Medical-surgical intensive care unit in the General Hospital of Rovigo. Patients 50 consecutive, mechanically ventilated, critically ill patients. All patients were in a coma and needed cerebral computed tomography (CT) for a diagnosis. Measurements and results The A-MU technique gave 100 images of maxillary and frontal sinuses. The images were read blindly and classified into five categories: definitely normal, definitely abnormal, probably normal, questionable, and probably abnormal. CT findings were considered to be the “gold standard”. The specificity of echo images varied from 72 to 98% and the sensitivity from 63 to 86% for maxillary sinuses. For frontal sinuses, the specificity varied from 96 to 99% and the sensitivity from 14 to 57%. The area under the receiver-operating characteristic curve was found to be 0.89 and 0.76 for maxillary and frontal sinuses, respectively. Conclusions The A-MU technique is an accurate tool for detecting secretion in the maxillary sinuses in intubated patients. More investigations are necessary in order to evaluate its usefulness in the frontal sinuses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1084
    Keywords: Key words: Stereolithography ; Rapid prototyping ; Computed tomography ; Calcaneal fracture ; ROC curves
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The purpose of this study was to evaluate and compare the diagnostic performance of stereolithography vs workstation-based three-dimensional (3D) reformations in intra-articular calcaneal fractures. A total of 30 intra-articular calcaneal fractures were examined using standard radiographs, coronal CT scans, and 2D and 3D reformations. The CT data were transferred to an outside institution, and stereolithograms were produced from photopolymer resin employing a laser beam system. 3D reformations and stereolithograms were analyzed in a blinded fashion by two staff radiologists. Receiver-operating-characteristic (ROC) curves were obtained for six clinically significant fracture components. Standard radiographs, coronal CT scans, and 2D reformations served as the standard of reference. The area under the ROC curves for 3D reformations and stereolithograms were 1.0 and 0.98 for abnormal tuber angles, 0.91 and 0.91 for anterior and middle talo-calcaneal joint involvement, 0.90 and 0.95 for involvement of the posterior talo-calcaneal joint, 0.65 and 0.78 for the presence of a lateral bulge, 0.80 and 0.81 for the involvement of the calcaneocuboidal joint, and 0.62 and 0.67 for the presence of a “tongue-type” fracture. No statistically significant difference was demonstrated for the two methods (Wilcoxon signed-rank test, p = 0.138). Based on our results stereolithograms did not prove to be statistically superior to workstation-based 3D reformations. Stereolithograms may still be useful for teaching purposes and for surgical planning at a thinking-efficacy level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1920
    Keywords: Key words Glioblastoma ; necrosis ; Magnetic resonance imaging ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In a previous study, we found that the extent of necrosis was the only radiological feature which correlated significantly with survival in patients with glioblastoma. The aim of this paper was to evaluate the variability and prognostic value of the extent of the necrotic area as seen on contrast-enhanced MRI and CT in a larger series. We studied 72 patients who underwent surgical removal of supratentorial glioblastomas and had CT and/or MRI with contrast medium before surgery; 38, all undergoing the same treatment (surgery plus radiotherapy), were followed clinically. Necrosis within the tumour varied greatly, ranging from none (only 1 case) to involvement of 76 % of the tumour. Survival data in the subgroup suggested that only patients with a small area of necrosis (less than 35 % of the tumour) had a significantly longer survival time. When necrosis involved more than 35 % of the mass, patients had a shorter survival time, without any further correlation with the extent of necrosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1920
    Keywords: Granuloma ; Pituitary ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Idiopathic pituitary granuloma is a rare disorder similar to lymphocytic adenohypophysitis. Few cases have been reported. We report a new histologically case proven with MRI. The patterns of clinical and radiological presentation and the management of this disorder are discussed. MRI findings suggestive of this condition include an intensely enhancing pituitary mass, associated with dural enhancement. Steroid therapy may be suggested avoiding unnecessary surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Nierentransplantate ; Magnetresonanztomographie ; Farbduplexsonographie ; Computertomographie ; Lymphographie ; Angiographie ; Key words Kidney transplantation ; Renal allografts ; MR imaging ; Color duplex sonography ; Computed tomography ; Lymphography ; Angiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Diagnostic imaging after renal transplantation is of high importance in the differential diagnosis of peri-and postoperative complications. Sonography with color duplex imaging is the method of choice in the diagnosis of acute transplant rejection. MRI is an additional method in the diagnosis of transplant dysfunction especially in diagnosis of perirenal fluid collections. MR angiography and MR urography are noninvasive diagnostic modalities with the potential to replace angiography and pyelography. Angiography, complemented by carbon dioxide angiography, still is the gold standard in the diagnosis of transplant artery stenosis.
    Notes: Zusammenfassung Die bildgebende Diagnostik nach Nierentransplantation hat einen hohen Stellenwert in der Differentialdiagnostik peri- und postoperativer Komplikationen. Die Sonographie mit Doppler- und Farbduplexsonographie ist die Methode der ersten Wahl in der Diagnostik der akuten Transplantatabstoßung. Die MRT kann als zusätzliche Methode in der Diagnostik der akuten Transplantatdysfunktion und insbesondere bei unklarer perirenaler Flüssigkeitsansammlungen nach Transplantation eingesetzt werden. MR-Angiographie und MR-Urographie sind ergänzende nichtinvasive Methoden, welche die Angiographie (DSA) und Pyelographie zunehmend ersetzen können. Die Angiographie, ergänzt durch die CO2-Angiographie, ist weiterhin der Goldstandard in der Diagnostik von Transplantatarterienstenosen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Journal of Physical Organic Chemistry 9 (1996), S. 398-402 
    ISSN: 0894-3230
    Keywords: Chemistry ; Theoretical, Physical and Computational Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The kinetics of complex formation between Pd(H2O)42+ and S-carboxymethyl-L-cysteine (SCMCH2) was investigated in the presence of sodium dodecyl sulphate in the acidity range between 2 M HClO4 and pH 5. Although the mechanism was not affected by the presence of anionic micelles, retardation (2·2 〈 pH 〈 5) and acceleration (pH 〈 2·2) of the complex formation were observed compared with its rate in aqueous solution. These effects were interpreted in terms of the long-range electrostatic interactions between the negatively charged micellar surface and ligand species which can be in different ionic forms depending on the pH.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Journal of Physical Organic Chemistry 9 (1996), S. 552-560 
    ISSN: 0894-3230
    Keywords: Chemistry ; Theoretical, Physical and Computational Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: N-Chloroamino acids are unstable in aqueous solution and decompose through different pathways depending on the reaction conditions, yielding precursors of carcinogenic and/or mutagenic compounds. One of these pathways is a 1,2-elimination process, which has scarcely received any attention and for which no systematic analysis is available. The process is first order relative to the N-chloroamino acid and to that of hydroxide ion. The use of 2,2,2-trifluoroethanol and 1,1,1,3,3,3-hexafluoropropan-2-ol buffer solutions established that the process is general-base catalysed. The reaction rate is affected by the presence of a methyl group on the nitrogen atom and the nature of the leaving group. The results show an important steric effect due to the alkyl substituents on the α-carbon. With bulky alkyl substituents on the α-carbon, and in particular in the case of N-alkylamino acids, the catalytic effect increases as the base strength decreases. To characterize the transition state, Brønsted's β and βlg were used. A More O'Ferrall-Jencks diagram shows the transition state structure changing from carbanion-like to nitrenium-like, a large perpendicular effect being evident. The reaction proceeds through a concerted mechanism AxhDHDN instead of the stepwise AxhDH
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    International Journal of Quantum Chemistry 61 (1997), S. 405-414 
    ISSN: 0020-7608
    Keywords: Chemistry ; Theoretical, Physical and Computational Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Density functional calculations are reported for the molecular structures, harmonic vibrational frequencies, UV/visible spectra, and oxo-transferability of MoO2X2 (X = F, Cl, Br, I). Available experimental data have been used to check the validity of the theoretical calculations. Given the good agreement between theory and gas-phase experiment, predictions have been issued for the less studied members of this family of compounds. Furthermore, electronic spectra of the full series have been computed for the first time. For all transitions studied, excitation energies decrease in the order F 〉 Cl 〉 Br 〉 I. Finally, the labilization of Mo(SINGLE BOND)O bonds generated by the HOMO(SINGLE BOND)LUMO transition, which is related to the oxygen-atom transfer reaction in the active site of molybdenum oxidoreductases, was also investigated. For MoO2Cl2 and MoO2Br2 compounds, the HOMO-LUMO transition yields a considerable lengthening of the Mo(SINGLE BOND)O bond, yet not requiring a large excitation energy. © 1997 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    International Journal of Quantum Chemistry 66 (1998), S. 31-45 
    ISSN: 0020-7608
    Keywords: magnetic susceptibility ; magnetic shielding tensor ; gauge invariance ; Chemistry ; Theoretical, Physical and Computational Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A transformation of the transverse Coulomb vector potential was implemented to calculate molecular magnetic properties via the random-phase approximation (RPA) within the framework of a “longitudinal gauge.” In this gauge, the diamagnetic contribution to magnetic susceptibility is a tensor with equal diagonal components as in atoms, irrespective of molecular symmetry, whereas diagonal and average diamagnetic contributions to the nuclear magnetic shielding are the same as in the Coulomb gauge. Near-Hartree-Fock magnetic susceptibility and nuclear magnetic shielding tensors were evaluated for a set of small molecules, HF, H2O, NH3, and CH4, employing extended Gaussian basis sets. The peculiar features of the longitudinal gauge, and the fulfillment of a series of sum rules involving the virial operator, which must be satisfied to guarantee gauge invariance of total magnetic tensors, were exploited to check the degree of convergence of theoretical values and to estimate the corresponding Hartree-Fock limit for the properties.   © 1998 John Wiley & Sons, Inc. Int J Quant Chem 66: 31-45, 1998
    Additional Material: 15 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...