Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Plant molecular biology 19 (1992), S. 1011-1017 
    ISSN: 1573-5028
    Keywords: frameshift mutation ; lectin genes ; Medicago truncatula
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract We report the cloning and characterization of two lectin genes from Medicago truncatula, designated Mtlec1 and Mtlec2. The two genes show a high degree of homology and apparently belong to a small multigene family. Mtlec1 appears to encode a functional lectin with 277 amino acids, whereas Mtlec2 is probably non-functional, since a frameshift mutation (insertion of two nucleotides) leads to premature translation termination after only 98 amino acids. The deduced amino acid sequence of the polypeptide MtLEC1 suggests that this lectin is a metalloprotein with Glc/Man specificity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Journal of materials science 14 (1979), S. 749-751 
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Experimental mechanics 16 (1976), S. 209-214 
    ISSN: 1741-2765
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Two new techniques making use of the scattered-light speckle pattern have been developed which yield the displacements on an arbitrary interior plane of a 3-D body. When a sheet of coherent light passes through a transparent 3-D body, a small fraction is scattered. This scattered light produces a speckle pattern in an imaging system. By recording two superimposed images of this speckle pattern, one before and one after body deformation, the displacements on the interior illuminated plane can be found. The technique of scattered-light photography uses a single illuminating beam and is sensitive to displacements greater than one speckle diameter, approximately 3 μm. Scattered-light speckle interferometry uses two illuminating beams and is sensitive to displacements greater than one half the wavelength of light being used, approximately 0.2 μm. With both techniques, the double-exposed speckle photograph is optically processed to yield displacement information. With both techniques, the maximum displacement measurable is limited by correlation requirements between the two speckle patterns. Experimental results are presented demonstrating the two new techniques.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Experimental mechanics 17 (1977), S. 241-247 
    ISSN: 1741-2765
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract The variation in Mode I stress-intensity factor throughout the thickness of an ASTM standard compact tension specimen was determined using scattered-light speckle interferometry. Two very thin sheets of coincident coherent light traveling in opposite directions were passed through a Plexiglas specimen normal to the crack faces. A double-exposed photograph of the scattered-light speckle pattern was taken while the specimen was subjected to a small load increment. From this double-exposed photograph, the change in the crack-opening displacement could be determined. From the information about the crack-opening displacement in the region of the crack tip, the stress-intensity factor was calculated for various interior planes and on the surface of the specimen. For the compact tension specimen tested, the stress-intensity factor did not vary throughout the specimen's thickness. The method of scattered-light speckle interferometry proved to be very powerful in solving this complex three-dimensional problem.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Process Safety Progress 12 (1993), S. 216-221 
    ISSN: 1066-8527
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The majority of buildings located at petrochemical plants, exclusive of control rooms, are of conventional construction and do not explicitly provide for resistance to blast loads. Typical construction types include steel frame with metal cladding, concrete masonry unit, and brick clad with concrete or steel frame. These buildings are designed for conventional loads without regard for high overpressures and fragments resulting from an accidental explosion. Current regulatory trends are causing many companies to evaluate design standards for new and existing support structures especially in the wake of recent accidental explosions. Response criteria is an important part of these design standards especially when they are used to analyze existing structures for blast protection. Structural evaluations at several sites have revealed that few existing structures meet current design criteria primarily due to weak member connections. Previous work has shown that many conventional structures can develop a surprising degree of resistance to blast loading if proper detailing is used in design, thus allowing members to develop their full capacity. This paper discusses response criteria currently used for new structures and examines the problem of determining acceptance criteria for existing structures. Data from explosion accidents and test programs is reviewed to determine the degree of conservatism in current criteria. Finally, alternatives for establishing blast capacity of existing structures are discussed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Plant/Operations Progress 11 (1992), S. 205-212 
    ISSN: 0278-4513
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: There has been a great deal of investment in development of design criteria and design and construction of heavily reinforced, blast-resistant control rooms. This remains the best option for protective construction against severe blast loading experienced close in to a vapor cloud or other explosion hazard. However, most structures encountered at chemical plants and contemplated for future construction are conventional steel frame, metal clad buildings. In this paper we look closely at the response of such buildings to explosion loads and their ability to undergo large deformations without structural failure. The types of structural elements evaluated include metal decking of various gauge and shape along with a variety of girt and purlin sections. Building frames or bents are also evaluated, although the date base for these is much more limited. The work is based on observations made during investigations of large explosion accidents along with analytical predictions and test measurements. To conclude, we offer specific design criteria and connection recommendations for enhancing the overall strength of a building through the use of conventional components in unconventional construction.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...