Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (3)
  • 13C-NMR  (1)
  • Angiography instrumentation  (1)
  • Ceramides  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Entomologia experimentalis et applicata 66 (1993), S. 269-274 
    ISSN: 1570-7458
    Keywords: 13C-NMR ; 31P-NMR ; Nuclear magnetic resonance ; Tribolium confusum ; Glucose metabolism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Nuclear magnetic resonance (NMR) technology was applied to study the glucose metabolism inTribolium confusum (Coleoptera).13C signals of D-(1-13C)glucose eaten by beetles were clearly detected in such metabolites of the glucose metabolism as glycogen, trehalose, triacylglycerol, alanine and proline by13C-NMR. After glucose feeding the31P-NMR spectra ofT. confusum showed the signal intensity increases in arginine-phosphate, sugar-phosphate and uridine diphosphoglucose. The results demonstrated the potential of NMR analysis for the study of glucose metabolism inT. confusum.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 285 (1993), S. 415-417 
    ISSN: 1432-069X
    Keywords: Sphingolipids ; Ceramides ; Aging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We measured six stratum corneum sphingolipid species (ceramides 1–6) in 26 males and 27 females, and found a significant change in their percentage composition only among female subjects of different age groups. There was a significant increase in ceramide 1 and 2 with a corresponding decrease in ceramide 3 and 6 from prepubertal age to adulthood. Thereafter the ratio of ceramide 2 to total sphingolipids decreased with age in contrast to ceramide 3 which showed an increase. Such a pattern of change in the aging population is different from that observed in scaly skin experimentally induced by tape stripping. The present results suggest a significant influence of female hormones on the composition of stratum corneum sphingolipids. Moreover, the different patterns of change in sphingolipid composition of stratum corneum lipids between scales from inflammatory skin and those from aged skin also suggest that epidermal biosynthesis of sphingolipids is influenced by epidermal proliferative activity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1920
    Keywords: Neuroangiographic unit ; Interventional procedures ; Stereoscopic angiography ; Magnification angiography ; Angiography instrumentation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A new neuroangiographic unit was developed with a ceiling-suspended gantry, capable of rotation (110°) and craniocaudal angulation (±45°) along the body axis. The gantry could also be rotated 225° at the ceiling suspension axis and sidetracked away from the angiographic table in case of emergency. Two sets of a twin-focus X-ray tube and a 12-inch image intensifier (II) were mounted on the gantry in the isocentric and cross-firing positions. High resolution 1024×1024 matrix digital radiography was obtained with a speed of 30 frames/s, while conventional film-screen radiography was obtained at 4 films/s. Rapid film changers were installed and interchangeable with the Hs. The lateral II and X-ray tube could be positioned from either side of the patient. There was no angulated position of the lateral imaging system during angulated anteroposterior or Towne projection of the frontal imaging system. Automatic repositioning of the gantry was possible to the preset position. Stereoscopic, magnification and stereoscopic magnification radiography could be obtained easily in monoplane or biplane mode. Switching from fluoroscopy to radiography and vice versa was possible rapidly and easily. Neuroangiographic as well as interventional procedures were performed expeditiously with lower complication rates. Suspending the gantry from the ceiling made more space available on the floor for the anesthesiologists.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...