Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Urological research 11 (1983), S. 285-290 
    ISSN: 1434-0879
    Keywords: Trace metals ; Cadmium ; Kidney cortex ; Ischaemic heart disease ; Medulla
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The trace element content of kidneys has been documented in very few international centres. Significant differences can be demonstrated between the cortical and medullary levels of calcium, zinc and cadmium. For the West of Scotland the values for the latter are similar to those found in Scandinavia. There are significantly higher cadmium contents in subjects who smoke and who have evidence of ischaemic heart disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Urological research 7 (1979), S. 285-289 
    ISSN: 1434-0879
    Keywords: Cadmium ; Iron ; Bendrofluazide ; Hypercalciuria Hyperzincuria ; Treatment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Cadmium induces a variety of effects on kidney tubules including hypercalciuria. This is accompanied by hyperzincuria. The present work shows that both of these biochemical abnormalities can be corrected but where a state of cadmium-induced-anaemia exists urine zinc and calcium excretion do not follow the expected parallel course in response to iron therapy as they do with bendrofluazide.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Urological research 5 (1977), S. 15-20 
    ISSN: 1434-0879
    Keywords: Cadmium ; Kidney ; Ultrastructure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Cadmium injection in rats affects the genito-urinary system. The renal effects are generally considered to be mainly tubular. Light microscopy of 29 specimens confirms cellular damage in the glomeruli with changes in glomerular capillaries. Electron microscopic changes in the glomeruli confirm changes in the podocytes, thickening of the basement lamina, the occurrence of electron dense deposits in association with the capillary endothelium with platelet and polymorphonuclear cell accumulations which suggests opening of the endothelial junction of the glomerular vessels.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 16 (1978), S. 296-301 
    ISSN: 1741-0444
    Keywords: Error analysis ; Myoelectric control
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Un système de commandes myoélectriques est celui, où le fonctionnement d'un dispositif est contrôlé par le potentiel électrique produit par la contraction volontaire d'un muscle. Ces systèmes sont surtout employés pour la commande de membres artificiels. Les premiers types de systèmes de commande était empiriques, mais de récents travaux ont produit des bases théoriques, pouvant prédire leur performance. Ceci devrait pouvoir améliorer les systèmes déjà existants, et rendre possible le développement de prothèses plus complexes.
    Abstract: Zusammenfassung Bei einem myoelektrischen Steuersystem wird der Betrieb eines Geräts durch ein elektrisches Potential gesteuert, das durch freiillige Kontraktion eines Muskels erzeugt wird. Diese Systeme wurden hauptsächlich zur Kontrolle künstlicher Glieder verwendet. Frühere Entwürfe des Steuersystems waren empirisch, jedoch wurden kürzlich einige theoretische Grundlagen erarbeitet, die ihre Leistung vorbestimmen können. Dieses wird zur Verbesserung der bestehenden Systeme führen und die Entwicklung mehr komplexer Prothesen wahrscheinlicher machen.
    Notes: Abstract A myoelectric control system is one in which the operation of a device is controlled by the electric potential produced by voluntary contraction of a muscle. These systems have been used mainly for the control of artificial limbs. Early design of the control systems was empirical, but recent work has provided some theoretical basis for predicting their performance. This should lead to improvements in existing systems and make feasible the development of more complex prostheses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 18 (1980), S. 65-69 
    ISSN: 1741-0444
    Keywords: Electrocutaneous stimulation ; Myoelectric control ; Prosthetics ; Sensory feedback
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Progress in the development of a system to provide sensory feedback of the pinch force of an artificial hand is described. Design criteria relating to electrocutaneous stimulation and compatibility with myoelectric control are discussed. Details of a practical system, presently in use by two amputees prior to full-scale clinical evaluation, are presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 25 (1987), S. 77-80 
    ISSN: 1741-0444
    Keywords: Myoelectric control ; Nerve stimulator ; Pulse burst ; Sensory feedback
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 29 (1991), S. 84-88 
    ISSN: 1741-0444
    Keywords: Control ; Interference ; Myoelectric ; Performance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Myoelectric signal is an important source of control information for powered prostheses. A commonly used performance measure for the signal processors of such control systems is the ratio of processor output mean to variance. This ratio (SNR) is a function of a number of factors including physiological parameters and additive interference. The paper investigates the effects of motor unit physiological parameters and interference on control performance, with particular reference to SNR. Performance equations are derived and verified within vivo experiments. The results show a complex interaction among the physiological parameters and interference. A particular point of interest is the misleading SNR values that can occur under certain recruitment and interference conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 20 (1982), S. 251-252 
    ISSN: 1741-0444
    Keywords: Batteries ; Myoelectric ; Prothesis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 203-205 
    ISSN: 1741-0444
    Keywords: Myoelectric control ; Battery saving device
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 527-530 
    ISSN: 1741-0444
    Keywords: Differential amplifiers ; Input impedance ; Myoelectric control
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Normal requirements for differential and common-mode input impedance of amplifiers for biological signals are reviewed. It is shown that these are not sufficient for satisfactory performance of amplifiers in myoelectric control applications, where accidental opening of the input circuit through electrode movement must not make the system susceptible to external noise. The additional constraint imposed by this application is examined, and a circuit is presented illustrating its practical resolution.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...