Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Elastizitätsmodul  (2)
  • Immunoscintigraphy  (2)
  • Polymer and Materials Science  (2)
  • (Ehrlich ascites cell membrane)  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochimica et Biophysica Acta (BBA)/Biomembranes 686 (1982), S. 27-35 
    ISSN: 0005-2736
    Keywords: (Ehrlich ascites cell membrane) ; Ca^2^+ permeability ; Energy depletion ; Ionophore ; Mitotic activity
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 260 (1982), S. 762-770 
    ISSN: 1435-1536
    Keywords: Druckbehandlung ; Elastizitätsmodul ; Netzwerkstruktur ; Polyäthylen ; Verstreckung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Abstract Samples of high density polyethylene were cold drawn at room temperature on a tensile testing machine at various crosshead speeds. At speeds up to 10 mm/min inhomogeneous stretching under almost isothermal conditions is observed, leading to draw ratiosλ=8–13 and a mean value of density ϱ ≃0.80 g/cm3 in the drawn portions. At higher speeds up to 50 mm/min adiabatic heating leads to higher draw ratiosλ=13–18 and lower density ϱ ≃ 0.64 g/cm3. No “natural draw ratio” could be verified. Whereas the drop of density with increasingλ can be represented by a straight line, Young's modulusE yields an increasing function ofλ. After subjecting the samples to pressure of 5600 bar at room temperature, their density had almost reached the initial value before drawing, not showing any dependence on draw ratio or any another parameter. Young's modulusE had increased, but not to the same proportion as density. From comparison ofϱ andE for drawn samples before and after pressure treatment the network behaviour of cold drawn polyethylene is revealed.
    Notes: Zusammenfassung Proben aus Polyäthylen hoher Dichte wurden bei Raumtemperatur mit verschiedenen Geschwindigkeitenv ver auf einer Zugprüfmaschine verstreckt. Beiv ver⩽ 10 mm/min beobachtet man eine fast isotherm verlaufende inhomogene Deformation, die zu Verstreckungsgradenλ=8–13 und mittleren Dichten ϱ = 0.80 g/cm3 in den verstreckten Probenbereichen führt. Die bei höherenv ver bis zu 50 mm/min eintretende adiabatische Erwähnung ergibt höhere Verstreckungsgradeλ=13–18 und geringere Dichten ϱ = 0.64 g/cm3. Es existiert kein „natürlicher Verstreckungsgrad“. Der Dichteabfall mit zunehmendemλ kann durch eine Gerade repräsentiert werden; der ElastizitätsmodulE ergibt eine mitλ zunehmende Kurve. Nach einer Druckbehandlung der Proben mit 5600 bar bei Raumtemperatur erreichte ihre Dichte fast wieder den Anfangswert vor der Verstreckung, wobeiϱ keine Abhängigkeit vonλ oder anderen Parametern zeigte. Der ModulE hatte zugenommen, aber nicht proportional zur Dichte. Der Vergleich vonϱ undE verstreckter Proben vor und nach der Druckbehandlung weist auf den Netzwerkcharakter von kaltverstrecktem Polyäthylen hin.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Keywords: Anti-CD4 monoclonal antibody ; Anti-carcinoembryonic antigen monoclonal antibody ; Immunoscintigraphy ; Technetium-99m labelling ; Rheumatoid arthritis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A direct comparison of the joint-imaging properties of inflammation-specific- and non-specific monoclonal antibodies (Mabs) was possible in a patient suffering from long-standing, severe rheumatoid arthritis (RA). This patient received an anti-CD4− and an anti-carcinoembryonic antigen (anti-CEA) Mab, both labelled with technetium-99m, 9 days apart from each other. The anti-CD4 Mab was superior to the isotype-matched anti-CEA Mab in imaging inflamed joints. In the knee joint, the target-to-background ratio of the synovial membrane (SM) activity in comparison to that of adjacent large vessels was 1.22 (SM/muscle 1.55) for the anti-CD4 Mab and 0.53 (SM/muscle 0.92) for the anti-CEA Mab, in both cases 4 h after injection of the immunoglobulin. Since the CD4 antigen is present on the surface of T-helper lymphocytes and macrophages infiltrating the inflamed synovial membrane, imaging with the anti-CD4 Mab may allow more specific detection of inflammatory infiltrates in RA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1619-7089
    Keywords: Immunoscintigraphy ; Technetium 99m-labelled antibodies ; CD4-specific (T-lymphocyte) antibodies ; Rheumatoid arthritis ; Localisation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract CD4 expressing T-lymphocytes are involved in the pathogenesis of rheumatoid arthritis, so the possibility of using radiolabelled CD4-specific antibodies to localise diseased joints was studied. Prospectively six patients with rheumatoid arthritis were investigated. Five of them received 200–300 μg of a 555 MBq technetium 99m CD4-specific antibody (MAX.16H5) and were examined with three phase bone scans. Max.16H5 (IgG1) was labelled according to the mercaptoethanol (Schwarz) method. Lymphocytes of one patient were isolated on a Ficoll-Hypaque gradient and labelled with the antibody in vitro. Scans were performed 1.5 h, 4 and 24 h post injection in anterior and posterior views. In all patients, diseased joints could be clearly imaged at as early as 1.5 h. The localisation of the diseased joints correlated (P〈0.01) with the clinical signs, with the early methylene diphosphonate (MDP) scan (P 〉 0.01) and only weakly with the late bone scan (P 〉 0.05). According to these data we conclude that99mTc-labelled CD4-specific antibodies specifically image actively diseased joints in rheumatoid arthritis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 260 (1982), S. 577-587 
    ISSN: 1435-1536
    Keywords: Elastizitätsmodul ; Polyäthylen ; Biegeschwingungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Abstract An apparatus is described which causes forced bending vibrations of cylindrical polymer samples in the frequency range of 1 to 10 Hz. Samples are clamped at one end; the other end is vibrating with constant amplitude, and bending forces are registered. By variation of the bending length of samples Young's modulus E0 at zero deformation can be calculated by means of an extrapolation method. To determine the true bending length of samples an additional constant lengthΔL is introduced. Measurements of high density polyethylene at 22 °C yieldE 0=2430 N/mm2 at 1 Hz. The results are compared with those of resonant vibrations.
    Notes: Zusammenfassung Es wird eine Apparatur zur erzwungenen Wechselbiegung zylindrischer Polymerproben im Frequenzbereich von 1 bis 10 Hz beschrieben. Ein Probenende wird fest eingespannt, das andere um einen konstanten Betrag ausgelenkt und die Biegekraft dabei gemessen. Durch Variation der Biegelänge der Proben kann man nach einem einfachen Extrapolationsverfahren den ElastizitätsmodulE 0 bei der Deformationε=0 bestimmen. Dabei wird die Einführung einer konstanten ZusatzlängeΔL zur Ermittlung der wahren Biegelänge begründet. Messungen an Polyäthylen hoher Dichte bei 22 °C ergabenE 0=2430 N/mm2 bei 1 Hz. Die Übereinstimmung mit den Ergebnissen von Resonanzmethoden wird diskutiert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 50 (1978), S. 956-957 
    ISSN: 0009-286X
    Keywords: Heterogene Katalyse ; Platin-Trägerkatalysatoren ; Bimetall-Katalysatoren ; Dispersität ; Aromatisierung ; Hydrogenolyse ; Aromatisierung ; n-Hexan ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 30 (1979), S. 426-431 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: The time-dependence of the permeation of methanol vapour through tenside-alginate foam lamels was determined by measuring the permeation, diffusion and solubility coefficients. Steady-state transport was found to occur only within narrow time limits. The agreement of calculated and experimental relationships between the coefficients suggest solution diffusion as proposed by BARRER. The transport mechanism can be explained by the place exchange theory and by the cluster theory according to LUCK.
    Notes: Für Tensid/Alginat-Schaumlamellen wurde der Durchtritt von Methanoldampf an Hand der Permeations-, Diffusions-und Löslichkeitskoeffizienten in Abhängigkeit von der Zeit ermittelt. Stationäre Transportzustände existieren nur in engen Zeitintervallen. Aus der Übereinstimmung zwischen den berechneten und experimentell ermittelten Koeffizienten-Beziehungen wird auf eine Lösungsdiffusion nach BARRER geschlossen. Der Transportmechanismus kann auf der Grundlage der Platzwechseltheorie sowie der Cluster-Theorie nach LUCK gedeutet wurden.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...