Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • cerebrospinal fluid  (8)
  • viscosity  (6)
  • MRI  (5)
  • Alzheimer type dementia  (2)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Neuroradiology 30 (1988), S. 579-581 
    ISSN: 1432-1920
    Schlagwort(e): Operculum syndrome ; Anterior opercular syndrome ; Foix-Chavany-Marie syndrome ; SPECT ; MRI
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Bilateral anterior opercular syndrome is clinically characterized by facio-pharyngo-glossomasticatory diplegia due to bilateral opercular lesions. Reported cases of the syndrome have been relatively rare probably because of difficulty in determining opercular damage on clinical symptoms alone. We report a case of this syndrome in whom bilateral opercular damage could be detected not by CT, but suggested by SPECT, and confirmed by MR imaging.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Neuroradiology 36 (1994), S. 340-345 
    ISSN: 1432-1920
    Schlagwort(e): Infarcts, anterior choroidal artery ; CT ; MRI ; Angiography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract We reviewed 12 cases of infarcts in the territory of the anterior choroidal artery (AChA) on CT and/or MRI. In each case vascular occlusion in the region was verified angiographically. Although the extent of the lesion on CT/MR images was variable, all were located on the axial images within an arcuate zone between the striatium anterolaterally and the thalamus posteromedially. The distribution of the lesions on mutiplanar MRI conformed well to the territory of the AChA demonstrated microangiographically. The variability of the extent of the infarcts may be explained by variations in the degree of occlusive changes in the AChA or the development of collateral circulation through anastomoses between the AChA and the posterior communicating and posterior cerebral arteries. The extent of the lesion appeared to be closely related to the degree of neurological deficit.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    European journal of pediatrics 154 (1995), S. 378-380 
    ISSN: 1432-1076
    Schlagwort(e): Key words Acute transverse ; myelitis ; MRI ; ECHO virus ; type 18 ; Reverse transcriptase ; Polymerase chain reaction
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract A 14-year-old boy developed acute quadriplegia, associated with sensory impairment and bowel and urinary dysfunction. MRI of the cervical cord showed diffuse increased signal intensity on T2-weighted images with gadolinium-diethylenetriamine penta-acetic acid enhancement. Based on the clinical presentation and MRI findings, the diagnosis of acute transverse myelitis was made. Enterovirus RNA was amplified from CSF by the reverse transcriptase-polymerase chain reaction. Serum neutralizing antibody to ECHO virus type 18 rose from 1/4 on admission to 1/16 2 months later. Conclusion This is the first reported case of acute transverse myelitis caused by ECHO virus type 18 infection.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    European journal of pediatrics 154 (1995), S. 378-380 
    ISSN: 1432-1076
    Schlagwort(e): Acute transverse myelitis ; MRI ; ECHO virus type 18 ; Reverse transcriptase ; Polymerase chain reaction
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract a 14-year-old boy developed acute quadriplegia, associated with sensory impairment and bowel and urinary dysfunction. MRI of the cervical cord showed diffuse increased signal intensity on T2-weighted images with gadolinium-diethylenetriamine penta-acetic acid enhancement. Based on the clinical presentation and MRI findings, the diagnosis of acute transverse myelitis was made. Enterovirus RNA was amplified from CSF by the reverse transcriptase-polymerase chain reaction. Serum neutralizing antibody to ECHO virus type 18 rose from 1/4 on admission to 1/16 2 months later. Conclusion This is the first reported case of acute transverse myelitis caused by ECHO virus type 18 infection.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1432-1084
    Schlagwort(e): Aberrant internal carotid artery ; Congenital absence of the internal carotid artery ; CT ; MRI ; MR angiography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract We retrospectively reviewed the imaging features of an aberrant course of the internal carotid artery (ICA) in one patient and its unilateral absence in four. Absence of the ICA was initially detected by MRI and MR angiography in both patients who underwent these examinations. CT revealed an abnormal or absent carotid canal in all cases. Radiological diagnosis by MRI and MR angiography could play an important role in the diagnosis.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    International journal of thermophysics 15 (1994), S. 109-115 
    ISSN: 1572-9567
    Schlagwort(e): ethylene glycol ; diethylene glycol ; HFC-134x ; polyethylene glycol(400) ; polypropylene glycol(2000) ; tetraethylene glycol ; triethylene glycol ; viscosity
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract The liquid viscosity of six binary mixtures of HFC-134a with glycols [ethylene glycol, diethylene glycol, triethylene glycol, tetraethylene glycol, polyethylene glycol(400), and polypropylene glyco](2000)] was measured in the temperature range from 273 to 333 K. The viscosity was measured with an improved capillary viscometer instead of the rolling-ball viscometer reported in our previous work. The measurement uncertainty was estimated to be 1.6%. Most of the present data are higher than previous data, and the gap between the two sets of data increases further in low-viscosity regions. The present results obtained with laminar flow are more reliable than previous results, which are indefinite because of the limit of usefulness of the rolling-ball viscometer in low-viscosity regions.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Springer
    International journal of thermophysics 16 (1995), S. 773-779 
    ISSN: 1572-9567
    Schlagwort(e): capillary viscometer ; density ; n-butane ; n-hexane ; squalane ; viscosity
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract Viscosity and density measurements are reported for binary liquid mixtures ofn-butane andn-hexane with squalane in the temperature range from 273 to 333 K. The viscosity measurements have been carried out by using a capillary viscometer calibrated with standard liquids. that is. JS5, JSIO, JS20, and water. The uncertainty in the viscosity data was estimated to be ± 1.7%. The density needed for the calculation of the viscosity has been measured by using a glass pycnometer within an accuracy of ±0.04%. In the prediction of the viscosity, the scheme of Assael et al. fails for mixtures of this type differing greatly in size.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    International journal of thermophysics 12 (1991), S. 105-117 
    ISSN: 1572-9567
    Schlagwort(e): capillary viscometer ; fluorocarbons ; refrigerants ; viscosity
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract Viscosity measurements were carried out on saturated liquid fluorocarbon refrigerants using an improved capillary viscometer for 11 kinds of fluorocarbon refrigerants; CCl3F (R11), CCl2F2 (R12), CHClF2 (R22), CBrF3 (R13B1), CH3CHF2 (R152a), CCl2FCClF2 (R113), CHCl2CF3 (R123), CHClFCClF2 (R123a), CH3CF3 (R143a), CClF2CCl2F2 (R114), and CH2FCF3 (R134a), in the temperature range from 273 to 353 K. An equation is given to represent the viscosity as a function of temperature.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    International journal of thermophysics 14 (1993), S. 45-53 
    ISSN: 1572-9567
    Schlagwort(e): density ; diethylene glycol ; ethylene glycol ; HFC-134a ; polyethylene glycol ; polypropylene glycol ; tetraethylene glycol ; triethylene glycol ; viscosity
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract Liquid viscosity and density of six binary mixtures of HFC-134a with glycols [ethylene glycol, diethylene glycol, triethylene glycol, polyethylene glycol (400), and polypropylene glycol (2000)] have been measured in the temperature range from 273 to 333 K. The viscosity was measured by a rolling-ball viscometer calibrated with standard liquids of viscosities and densities (JS5, JS10, JS20, and JS50). The density was measured with a glass pycnometer. The uncertainties of the measurements were estimated to be less than 3.4 % for viscosity and 0.04 % for density, respectively. An equation is given to represent the obtained viscosity values as a function of weight fraction and temperature.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Springer
    International journal of thermophysics 14 (1993), S. 339-342 
    ISSN: 1572-9567
    Schlagwort(e): density ; HCFC ; HCFC-141b ; HCFC-142b ; HCFC-225ca ; HCFC-225cb ; hydrochlorofluorocarbon ; viscosity
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract Measurements of saturated liquid viscosities and densities were performed on environmentally acceptable hydrochlorofluorocarbons (HCFCs), CH3CCl2F (HCFC-141b), CH3CClF2 (HCFC-142b; only for viscosity), CF3CF2CHCl2 (HCFC-225ca), and CClF2CF2CHClF (HCFC-225cb), using a capillary viscometer and a glass pycnometer in the temperature range from 273 to 353 K. The uncertainty in the measurement of viscosity is estimated to be 5% based on the comparison of the present data with those in the literature for HCFC-141b. An equation is given to represent our saturated liquid viscosity data as a function of temperature.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...