Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 65 (1987), S. 1081-1086 
    ISSN: 1432-1440
    Keywords: Hemodialysis ; Digitoxin ; Arrhythmias
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Digitoxin is considered a risk factor for ventricular arrhythmias in hemodialysis patients. In a randomized, crossover controlled study, 55 hemodialysis outpatients with sinus rhythm were prospectively investigated in two 48-h periods of electrocardiographic monitoring, one on and one off digitoxin or vice versa. The frequency of ventricular ectopic beats (mean±SD) which were found in 31 of 55 patients (56%), was slightly higher on hemodialysis (10±28 beats/h) than in the following 20 h (5.4±10 beats/h) and the next day off hemodialysis (3.6±6.6 beats/h); however, no difference was seen in patients on digitoxin during hemodialysis (10±29 beats/h), in the following 20 h (4.8±15 beats/h) and on the next day off hemodialysis (1.2±6.6 beats/h). The frequency of ventricular bigemini, polymorphous ectopies, couplets, more than 30 ectopies/h, salvos and tachycardias (10 vs 9 patients) on and off digitoxin was about the same (n.s., Fisher test). Supraventricular bigemini, salvos, tachycardias, and atrial fibrillation, however, occurred in significantly fewer patients on digitoxin (3 vs 13) than in those off digitoxin (P=0.01, Fisher test). It is concluded that digitoxin does not increase the risk of ventricular arrhythmias in hemodialysis patients. Digitoxin, however, may have a beneficial effect on the supraventricular arrhythmias frequently observed in these patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Anti-CD4 monoclonal antibody ; Anti-carcinoembryonic antigen monoclonal antibody ; Immunoscintigraphy ; Technetium-99m labelling ; Rheumatoid arthritis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A direct comparison of the joint-imaging properties of inflammation-specific- and non-specific monoclonal antibodies (Mabs) was possible in a patient suffering from long-standing, severe rheumatoid arthritis (RA). This patient received an anti-CD4− and an anti-carcinoembryonic antigen (anti-CEA) Mab, both labelled with technetium-99m, 9 days apart from each other. The anti-CD4 Mab was superior to the isotype-matched anti-CEA Mab in imaging inflamed joints. In the knee joint, the target-to-background ratio of the synovial membrane (SM) activity in comparison to that of adjacent large vessels was 1.22 (SM/muscle 1.55) for the anti-CD4 Mab and 0.53 (SM/muscle 0.92) for the anti-CEA Mab, in both cases 4 h after injection of the immunoglobulin. Since the CD4 antigen is present on the surface of T-helper lymphocytes and macrophages infiltrating the inflamed synovial membrane, imaging with the anti-CD4 Mab may allow more specific detection of inflammatory infiltrates in RA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...