Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Trace enrichment ; Membrane extraction disks ; Triazine herbicides ; 2,3,4-Trichlorophenol
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Membrane extraction disks have been recently introduced for the solid-phase extraction of organic compounds from aqueous samples. The material consists of alkyl-modified silica particles enmeshed in an inert PTEE matrix. Aqueous samples containing polar pesticides and herbicides, are preconcentrated on-line from acidic solutions on membrane extraction disks containing immobilized octadecyl-modified silica and analyzed with an isocratic liquid chromatographic system using PLRP-S as the stationary phase and aqueous acetonitrile mixtures (pH 3) as the eluent. Data on the lifetime and the dimensions of the preconcentration disks, and the efficiency and the repeatability of the procedure are reported. For 10 ml samples, the detection limits of the analytes atrazine, simazine and 2,3,4-trichlorophenol in tap water are 0.1–1 ppb.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ultrafiltration ; Fermentation monitoring ; Sugars
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An automated on-line monitoring system for low-molecular-weight compounds (e.g. sugars) during fermentation processes is described. The applicability of cross-flow ultrafiltration, coupled on-line with high-performance liquid chromatography, is evaluated. Various detection modes for the determination of the test compounds lactose, glucose and fructose) in a complex fermentation broth are compared. In addition, the influence of some system parameters on the performance of several ultrafiltration modules for the removal of cellular and macromolecular broth constituents is investigated. A method for the fully automated determination of sugars during anE. coli batch culture in a brain-heart infusion medium is presented. With the present system five analyses can be performed every hour, using only 35μl of sample, without significant deterioration of the ultrafiltration process. Contamination by external micro-organisms was not observed and good correlation with an off-line method was found.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Zone-electrophoretic sample treatment ; Basic and acidic compounds ; Biological samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modified valve arrangement for zone-electrophoretic sample treatment (ZEST)-which is coupled on-line with column liquid chromatography — is used to pretreat biological (plasma) samples. Carry-over of plasma proteins depends on the pH of the electrophoresis buffer. The determination of propranolol, metoprolol, cromolyn and salicylic acid demonstrates that both basic and acidic analytes can be isolated from the plasma matrix with high selectivity. Analogous piperazines, with different protein binding properties, were used to study the influence of protein binding on the recovery. It is shown that high protein can cause a decreased recovery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Atomic emission and MS detection ; Solid-phase extraction ; Aqueous samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC systems to enable the determination of microcontaminants at the 0.02–1 μg L−1 level in 7–50 mL of aqueous sample. The screening was limited to compounds present in at least one heteroatom-selective GC-AED trace above a predetermined concentration level. These compounds were identified by their partial formulae (AED) and the corresponding mass spectra, which were obtained from the GC-MS chromatogram via the retention index concept. The potential of the approach was demonstrated by the identification of target compounds as well as all unknowns present in tap and waste water above the predetermined threshold of 0.05 μg L−1 (tap water) or 0.5 μg L−1 (waste water).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Phase-transfer catalysis ; On-line derivatization ; Phenolic steroids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Commercially available equipment from two manufacturers served to set up an automated system for the precolumn phase-transfer-catalyzed dansylation of phenolic steroids, using ethynyl estradiol (EE) and estradiol (E) as model compounds. Using different mixing techniques, the on-line determination of EE and E in 200μl untreated urine samples was achieved at a rate of 3–8 analyses per hour. Detection limits were calculated to be 3–5 ng/ml. Calibration curves in urine were linear over two orders of magnitude with r=0.999 (n=5) for EE and r=0.999 (n=6) for E. The repeatability of the determination of EE in urine (1μg/ml) was 3.9% (RSD; n=20) and of E (1.5μl/ml) 3.8% (RDS; n=10). The use of plasma instead of urine in the on-line procedures was not possible due to rapid formation of emulsions, but E and EE were determined in 100μl plasma samples using a mild off-line mixing procedure in 10min. Detection limits were calculated to be ca 10ng/ml. A reaction detector, based on a solvent-segmented system, was developed for the on-line post-column dansylation of phenols and was coupled with a reversed-phase LC system. The highly selective system showed excellent linearity over at least two orders of magnitude with r=0.9999 (n=6) for both phenol and 2,5-dimethylphenol. The reproducibility was good with RSD values of around 2%. Detection limits for loop injections from standard solutions were calculated to be between 4 and 11ng.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrodialytic sample treatment ; On-line coupling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An electrodialytic sample treatment method coupled on-line with high-performance liquid chromatography (EDIST-HPLC) is discussed in this paper. The performance of EDIST as a function of the donor-phase (sample solution) flow rate, the voltage applied over the electrodialysis block, and the time of dialysis has been studied using the basic drug ephedrine as a model compound. Enrichment of the analyte by a factor of 10–20 was possible. The determination of human plasma spiked with ephedrine is briefly discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Immunoaffinity precolomn ; Oestrogens ; Bioanalysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An automated liquid chromatographic system is described using immunoaffinity precolumns for sample pretreatment. The system consists of a column-switching unit allowing preconcentration from a large volume of sample (e.g. 15 ml of urine) onto an immunoaffinity precolumn (containing polyclonal antibodies immobilized on Sepharose). After sorption, the analytes are desorbed by a mixture of two cross-reacting solutes, followed by reconcentration on a C-18-bonded silica precolumn, and then separation on a C-18-bonded silica analytical column. Using oestrogen steroids as model compounds and UV absorbance detection, the minimum detectable concentration is ca. 200 ng/l with a repeatability of 6–8%. The total analysis time is 45 min which allows the unattended analysis of 30 samples per day. The features of the sample pretreatment method, especially of the immunoselective desorption, are evaluated and the general applicability of the system is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrodialytic sample treatment ; Computer models ; Analyte enrichment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Basic considerations for analyte enrichment and recovery obtainable by electrodialysis as a sample treatment method are given. Equations are derived which describe the dependence of the concentration profiles of ionic compounds on the electric field strength in a set-up with stagnant donor and acceptor solutions. It is shown that analyte recovery increases when less ion-selective membranes are used in the electrodialysis cell. Computer models are used to estimate the analyte enrichment for a flowing donor (sample) and a stagnant acceptor phase. About 10-fold enrichment can be obtained in an electrodialytic sample treatment system within 20 min under maximum current conditions. A compromise has to be found between analyte recovery and the donor (sample) flow rate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Membrane-extraction disks ; On-line trace enrichment ; Polar pollutants ; Surface water
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An on-line trace-enrichment system, using a bifunctional membrane extraction-disk cartridge, has been combined with a column liquid chromatography separation for the simultaneous determination of basic, neutral and acidic pollutants in surface water. The enrichment device consisted of a specially constructed holder containing both C-18 and cation-exchange disks. The holder can contain up to 25 disks of 0.5 mm thickness and 4.6 mm diameter. Before trace enrichment of 20 ml of surface water (pH 3.0), calcium ions were removed from the sample by means of an oxalic acid precipitation. Desorption of the cartridge was at elevated temperature using reversed-phase gradient elution; detection was performed with a diode-array UV absorbance detector. The detection limits for the test compounds in surface water are typically 0.5–2 μg/l; the calibration graphs are linear from the lower limit of determination up to 50 μg/l.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Two-dimensional separation ; D- and L-amino acids ; Enantioseperation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A two-dimensional, column liquid chromatographic system is used for the determination of the D- and L-enantiomers of amino acids in biological samples. Separation of the amino acids is first on ion-exchange column by gradient elution with a sodium citratesodium chloride buffer. Enantioseparation is by subsequent injection of 3 μl heart-cuts of the individual amino acids onto a second column with a chiral crown ether stationary phase. Finally, fluorescence detection is after post-column labelling of the amino acids using ano-phthalaldehyde-2-mercaptoethanol reagent solution. The high separation power and selectivity of the system allow processing of complex samples with hardly any additional treatment and the determination of small quantities of D-amino acids in the presence of excess L-form. Applicability of the system is illustrated by the determination of D- and L-aspartate, serine, glutamate and alanine in various complex biological samples, such as protein hydrolysates, urine and biotechnological and food samples. Data are given on detectability, repeatability and linearity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...