Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Zone-electrophoretic sample treatment ; Basic and acidic compounds ; Biological samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modified valve arrangement for zone-electrophoretic sample treatment (ZEST)-which is coupled on-line with column liquid chromatography — is used to pretreat biological (plasma) samples. Carry-over of plasma proteins depends on the pH of the electrophoresis buffer. The determination of propranolol, metoprolol, cromolyn and salicylic acid demonstrates that both basic and acidic analytes can be isolated from the plasma matrix with high selectivity. Analogous piperazines, with different protein binding properties, were used to study the influence of protein binding on the recovery. It is shown that high protein can cause a decreased recovery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrodialytic sample treatment ; On-line coupling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An electrodialytic sample treatment method coupled on-line with high-performance liquid chromatography (EDIST-HPLC) is discussed in this paper. The performance of EDIST as a function of the donor-phase (sample solution) flow rate, the voltage applied over the electrodialysis block, and the time of dialysis has been studied using the basic drug ephedrine as a model compound. Enrichment of the analyte by a factor of 10–20 was possible. The determination of human plasma spiked with ephedrine is briefly discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrodialytic sample treatment ; Computer models ; Analyte enrichment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Basic considerations for analyte enrichment and recovery obtainable by electrodialysis as a sample treatment method are given. Equations are derived which describe the dependence of the concentration profiles of ionic compounds on the electric field strength in a set-up with stagnant donor and acceptor solutions. It is shown that analyte recovery increases when less ion-selective membranes are used in the electrodialysis cell. Computer models are used to estimate the analyte enrichment for a flowing donor (sample) and a stagnant acceptor phase. About 10-fold enrichment can be obtained in an electrodialytic sample treatment system within 20 min under maximum current conditions. A compromise has to be found between analyte recovery and the donor (sample) flow rate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Sample treatment ; Zone electrophoresis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The design of a new valve arrangement for zone-electrophoretic sample treatment (ZEST) coupled online with high performance liquid chromatography is described. Characteristics of this valve, such as the internal heat development as a function of the current, have been investigated. By using quinidine and desipramine as model compounds it is shown that charged compounds can be isolated from biological samples, in about 15 min, with high selectivity. The carry-over of proteins to the analytical column has been compared with the carry-over using a pre-column sample clean-up method. The detection limits of quinidine and hydroquinidine (50 ng/ml), using zone-electrophoretic sample treatment coupled with column liquid chromatography, are in the same range as with direct injections using pre-columns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...