Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Blood flow velocity  (1)
  • Key words Protein S-100 –¶cardiopulmonary bypass –¶near infrared spectroscopy –¶pediatric cardiac surgery  (1)
  • Key words Three-dimensional reconstructions  (1)
Material
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 152 (1993), S. 232-235 
    ISSN: 1432-1076
    Keywords: Cerebral arteries ; Blood flow velocity ; Newborn infant ; Tobacco smoke ; Pregnancy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cerebral blood flow velocities (CBFV) were measured by the pulsed Doppler method in 41 infants of smoking mothers and in 59 apparently healthy control infants. Although gestational age, birth weight, and systolic blood pressure were lower in infants exposed to tobacco smoke prenatally, systolic (65±11 vs. 47±12 cm/s, mean ±SD;P〈0.001), mean (36±6 vs. 25±6 cm/s;P〈0.001), and diastolic (17±4 vs 13±4 cm/s;P〈0.001) CBFVs in the anterior cerebral artery were significantly higher when compared to control infants. Similar differences were seen in the internal carotid and in the basilar arteries. Multiple regression analysis did not reveal differences other than maternal smoking to explain these observations. We conclude that prenatal tobacco smoke exposure is related to increased CBFVs in newborn infants. Further studies should determine whether this relation is not only statistical but causal and whether increased CBFVs are an indicator of prolonged effects of prenatal tobacco smoke exposure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Monatsschrift Kinderheilkunde 145 (1997), S. 1071-1075 
    ISSN: 1433-0474
    Keywords: Schlüsselwörter Ultraschall ; Gehirn ; Angeborene Herzfehler ; 3dimensionale Rekonstruktion ; Key words Three-dimensional reconstructions ; Ultrasound of the brain
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Objective: We assessed the utility of 3D ultrasound in detecting morphological changes of cerebral anatomy in newborns. Methods: Transfontanel cross-sectional ultrasound scans were obtained in standardized coronal and median sagittal planes. Subsequently, rotational scanning was used to acquire the multiple sequential cross-sections of the brain. A conventional 5 MHz transducer was rotated 180 degrees by a computer-controlled stepper motor and an image of the brain was obtained at each step of motion to obtain a three-dimensional dataset. Data was stored in the image processing computer which allowed for off-line three dimensional reconstruction of different brain regions. Results: Cavity of lateral ventricle, and periventricular brain parenchyma could be reconstructed in all. Accurate estimation of size and volume of ultrasonographically visible pathological brain lesions could be performed. Epicortical and subarachnoidal space could be reconstructed in all and allowed detection of hemorrhage in one case which was not detected by conventional ultrasound. Conclusion: 3D reconstruction of different areas of the brain may provide additional quantitative information on size and volume of the internal ventricle and better understanding of the topographical aspects and the extension of intra- and periventricular morphological abnormalities than conventional cross-sectional ultrasound.
    Notes: Zusammenfassung Fragestellung: Ausgehend von eigenen Erfahrungen mit der 3dimensionalen Echokardiographie wurde versucht, auch ultrasonographische transfontanelle Studien 3dimensional zu rekonstruieren und auf ihren Informationsgehalt zu untersuchen. Methode: Es wurden 16 Neugeborene und Säuglinge (Alter 4 Tage – 3 Monate, Median 12 Tage) untersucht. Ein konventioneller 5-MHz-Schallkopf wurde auf der anterioren Fontanelle plaziert und von einem computergesteuerten Motor im inneren Lumen eines offenen Zylinders um 180° um seine vertikale Achse gedreht. Bei jeder Drehung um jeweils 1° wurde eine Schicht des Gehirns aufgenommen, so daß 180 Schichten erhalten wurden, welche den 3dimensionalen Datensatz bilden. Innerhalb des Datensatzes können beliebig im Raum orientierte Schnittebenen rekonstruiert werden. Ergebnisse: Bei allen Patienten gelang es, Datensätze aufzunehmen, welche qualitativ so gut waren, daß sie später 3dimensional rekonstruiert werden konnten. Die Daten konnten ohne Sedierung und in weniger als 60 s aufgenommen werden. Rekonstruktionen des Gehirns dauerten 2–33 min. Es konnten neue transversale Schnittebenen des Schädels rekonstruiert werden, welche bisher nicht erhältlich waren. Neue Informationen konnten über subarachnoidal gelegene Hirnläsionen sowie die räumliche Ausdehnung von Parenchymblutungen gewonnen werden. Schlußfolgerungen: Dieses neue bildgebende Verfahren könnte in Zukunft quantitative und qualitative diagnostische Informationen der herkömmlichen Ultrasonographie verbessern.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1435-1420
    Keywords: Key words Protein S-100 –¶cardiopulmonary bypass –¶near infrared spectroscopy –¶pediatric cardiac surgery ; Schlüsselwörter Protein S-100 – Spektroskopie im Nahinfrarotbereich – extrakorporale Zirkulation –¶Kinderherzchirurgie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Fragestellung: Das Ziel diese prospektiven Studie war, die Serumkinetik des hirnspezifischen Markers Protein S-100, eines Gliazell- und Astrozytenproteins, in Beziehung zur kontinuierlich registrierten zerebralen Oxygenierung vor und nach Korrekturoperationen angeborener Herzfehler zu evaluieren.¶   Methodik: Die regionale zerebrale Hämoglobin-Sättigung wurde mit Hilfe der Nahinfrarotspektroskopie (INVOS 3100A, Somanetics®, USA) bestimmt und das Protein S-100 mittels eines doppelseitigen Radioimmunassays analysiert (Sangtec® 100 IRMA, Bromma, Schweden).¶   Ergebnisse: Das Protein S-100 war bei allen Kindern ohne nachweisbare neurologische Komplikationen nach Ende der extrakorporalen Zirkulation um 2 Standardabweichungen des präoperativen Ausgangswertes erhöht gefunden (p〈0,0001). Die maximalen Serum-S-100-Konzentrationen korrelierten signifikant mit dem Alter (r=–0,75, p〈0,0001) und Gewicht (r=–0,72, p=0,005) der Kinder, der Bypasszeit (r=0,44, p=0,005) und der minimalen rektalen Temperatur (r=–0,67, p=0,004) während der extrakorporalen Zirkulation. Ein statistischer Zusammenhang fand sich zwischen dem postoperativen Serumspiegel des Protein S-100 und dem Abfall der regionalen zerebralen Hämoglobin-Sättigung während der Reperfusion (r=–0,37, p=0,02) und am Ende der extrakorporalen Zirkulation (r=¶–0,42, p=0,008).¶   Schlußfolgerung: Die Astrogliazellen scheinen auf die extrakorporale Zirkulation mit einer Expression des Protein S-100 zu reagieren. Eine Membranschädigung im endothelialastrozytären Zellkomplex der Blut-Hirnschranke könnte die Freisetzung des Proteins in die Blutstrombahn erklären. Beeinflussende Faktoren scheinen geringes Alter, Länge der extrakorporalen Zirkulation, Grad der Hypothermie und mögliche Reduktion der postoperativen zerebralen Oxygenierung zu sein.
    Notes: Summary Introduction: The aim of this study was to investigate the kinetic patterns of the protein S-100, a specific cerebral astroglial cell protein, and the relationship to changes of cerebral oxygenation before, during, and after corrective cardiac surgery in infants and children.¶   Methods: 63 neonates, infants and children (age range 0.2–216 months) were included. Cardiac surgery was performed using full-flow cardiopulmonary bypass with moderate hypothermia and alpha-stat strategy. Regional cerebral hemoglobin saturation was continuously determined by near infrared spectroscopy (INVOS 3100A, Somanetics®, USA). The protein S-100 serum concentrations were analyzed using a commercially available two-site immunradiometric assay kit (Sangtec® IRMA, Bromma, Schweden).¶   Results: A significant increase in serum levels of S-100 was found immediately after termination of cardiopulmonary bypass (p〈0.001). The post-bypass S-100 serum levels significantly correlated with age ¶(r=–0.75, p〈0.0001), weight (–0.72, p〈0.005), bypass time (r=0.44, p=0.005), minimal rectal temperature (r=–0.67, p=0.004) and the decrease of regional cerebral hemoglobin saturation during reperfusion (r=–0.37, p=0.02) and at the end of cardiopulmonary bypass (r=–0.37, p=0.008).¶   Conclusion: The release patterns of S-100 in association with CPB may indicate increased cell membrane permeability of the astrocytic-endothelial cell complex forming the blood-brain barrier. The increased post-bypass serum levels of S-100 were related to younger age, longer duration of bypass, deep hypothermia and decreased regional intravascular cerebral oxygenation during reperfusion and at the termination of cardiopulmonary bypass.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...