Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (11)
  • Brain tumors  (1)
  • Cementless implant  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Der Orthopäde 26 (1997), S. 251-257 
    ISSN: 1433-0431
    Keywords: Schlüsselwörter Hüftprothese ; Zementfreie Prothese ; Computergesteuerter Robotereinsatz ; Präoperative Planung ; ROBODOC ; Key words Hip replacement ; Cementless implant ; Robot-assisted surgery ; Preoperative planning ; ROBODOC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Computer-guided robot-assisted surgery in cementless total hip replacement requires exact preoperative planning at the 3D workstation Orthodoc. Only the Robodoc procedure allows the precise execution of the preoperative plan in surgery. Robot-assisted surgery has been undergoing clinical evaluation at the Berufsgenossenschaftliche Unfallklinik, Frankfurt, since November 1994. In all 465 patients, the preoperative plan was successfully carried out intraoperatively. The high precision in reaming, leading to a superb bone implant contact, guarentees absolute initial stability and is likely to promote primary healing between implant and bone. The common and often published incidence of varus or valgus malpositioning and any fractures or fissures could be avoided through the use of Robodoc. Although immediate full-weight bearing was strongly recommended to the patients, no implant subsidence was seen in the regular follow-up X ray studies. In der Literatur beschriebene Varus- sowie Valgusfehlstellungen sowie intraoperativ aufgetretene Frakturen bzw. Fissuren konnten bei der Anwendung dieser Operationsmethode vermieden werden. Trotz sofortiger erlaubter postoperativer Belastung konnte eine Sinterung des Prothesenschaftes auch bei den regelmäßig durchgeführten Verlaufskontrollen nicht nachgewiesen werden.
    Notes: Zusammenfassung Der computergesteuerte Robotereinsatz bei der Implantation einer zementfreien Prothese erfordert eine exakte präoperative Planung am dreidimensionalen Graphik-Computer (Orthodoc). Erstmals ist es mit diesem Verfahren möglich, daß die in 3 Ebenen erfolgte Planung durch den computergesteuerten Robotereinsatz am Patienten umgesetzt werden kann. Seit Herbst 1994 wird an der Berufsgenossenschaft Unfallklinik Frankfurt am Main dieses Verfahren eingesetzt. Bei bisher 465 operierten Patienten konnte in allen Fällen die präoperative Planung intraoperativ umgesetzt werden. Es kann davon ausgegangen werden, daß aufgrund eines wesentlich verbesserten Knochenkontaktes, bedingt durch die hohe Präzision beim Fräsvorgang und der dadurch erreichbaren hohen Primärstabilität ein besseres Anwachsverhalten durch den Knochen gegeben sein wird.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 38 (1998), S. 394-398 
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Dreidimensionale Bildgebung ; Ultraschallkontrastmittel ; Transkranielle Duplexsonographie ; Power-Doppler ; Hirntumoren ; Key words Three-dimensional imaging ; Ultrasound contrast agents ; Transcranial duplex sonography ; Power Doppler ; Brain tumors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Echo-enhancing agents improve the signal intensity of transcranial Doppler signals, enabling a novel approach of three-dimensional transcranial vascular imaging by Doppler ultrasound. The basic principle, system requirements and early clinical results with a custom built system are described. Transcranial color Doppler imaging was performed through the temporal bone acoustic window. During IV administration of the transpulmonary stable, galactose-based echoenhancer Levovist® (Schering) the video output of the ultrasound scanner was digitized and the spatial position of the recorded frames was simultaneously registered using a mechanical position sensor. After automatic segmentation of the color information, the 3D datasets were reconstructed offline using a Unix-based workstation (Silicon Graphics). Visualization was achieved by maximum intensity projection or surface visualization techniques. Administration of Levovist® resulted in good enhancement of the vascular Doppler signal intensity, enabling acquisition of a 3D dataset of the complete circle of Willis with an imaging window of approximately 3–5 min for one IV injection. The vascularity of tumors could be recorded as a 3D dataset and further analyzed. The power Doppler technique with echoenhancement proved a valuable tool for 3D dataset recording. 3D datasets clearly facilitated the diagnosis of the vascular anatomy and lesion vascularity and provided additional information on localization of feeders, vascular displacement and extent of tumor vascularity.
    Notes: Zusammenfassung Echosignalverstärker verbessern die Signalintensität des transkraniellen Dopplersignals und ermöglichen damit die dreidimensionale Darstellung mittels transkraniellem Doppler-Ultraschall. Die grundlegenden Prinzipien, Systemvoraussetzungen und erste klinische Ergebnisse werden berichtet. Transkranielle Bildgebung erfolgte mit einem konventionellen Farbdopplersystem durch die intakte Schädelkalotte des Os temporale. Das Videosignal des Ultraschallgerätes wurde während der i.v. Applikation des galaktosebasierenden Echosignalverstärkers Levovist® (Schering) digitalisiert und die Position des jeweiligen Bildes mit einem mechanischen Sensorsystem erfaßt. Die Farbinformation wurde automatisch segmentiert und ein dreidimensionaler Datensatz daraus rekonstruiert, der auf einer Unix Workstation (Silicon Graphics) mittels Maximum-intensity-Projektion oder Oberflächendarstellung visualisiert wurde. Die Anwendung von Levovist® zeigte eine gute Signalverstärkung in einem Zeitraum von 3–5 min für eine i.v. Injektion, der eine Erfassung eines 3D-Datensatzes des kompletten Circulus Willisii bei allen Patienten ermöglichte. Zusätzlich konnte die Vaskularisation von Tumoren bei einigen Patienten dargestellt und weiter analysiert werden. Die angewandte Power-Doppler-Technik bildete zusammen mit Echosignalverstärkung die Basis für die Aufnahme bestmöglicher 3D-Datensätze. Die 3D-Visualisierung erleichterte die Darstellung komplexer Gefäßverläufe und zeigte zuführende Gefäße, Gefäßverlegungen und hochvaskularisierte Bereiche in Tumoren auf.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 32 (1981), S. 555-558 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: A generally postulated for polymer solids the linear theory of viscoelasticity applies adequately to the mechanical behaviour of individual filaments the initial region of the strees-strain relationship. This, however, does not hold true with multifilament yarns, due to the bundle effect. The dirferent moduli defined for polymer solids, as dynamic modulus, static modulus, tangent modulus and amplitude modulus, can be arranged into an appropriate scheme.
    Notes: Zur Beschreibung des mechanischen Verhaltens von Elementarfäden im Anfangsbereich der Spannungs-Dehnungs-Kurve ist die lineare Viskoelastizitätstheorie verwendbar, wie es für hochpolymere Festkörper allgemein postuliert wird. für Chemieseiden trifft dies auf Grund des Bündeleffektes nichhtzu. Die verschiedenen an hochpolymeren Festkörpern ermittelbaren Moduli, wie dynamischer Modul, statischer Modul, Tangentenmodul, Amplitudenmodul, lassen sich in ein Schema einordnen.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 31 (1980), S. 596-600 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: The mathematical formalism of the linear theory of viscoelasticity for the transformation of various parameters of materials determined by experimental methods is described. Experimental investigations with polyamide-6, polyester and polyacrylonitrile filament yarns suggest that these materials are not characterized by linear viscoelastic behaviour and, thus, the linear theory of viscoelasticity cannot be applied for the general description of the behaviour of synthetic fibres even in the region of small strain. This should be considered in model calculations.
    Notes: Der im Rahmen der linearen Viskoelastizitätstheorie gültige mathematische Formalismus der Umrechnung verschiedener experimentell ermittelbarer Material-Parameter wird dargestellt. Experimentelle Untersuchungen an Polyamid-6-Seide, Polyester-Seide und Polyacrylnitril-Seide deuten darauf hin, daß diese Materialien kein linearviskoelastisches Verhalten aufweisen und somit die lineare Viskoelastizitätstheorie zur allgemeinen Beschreibung des mechanischen Verhaltens dieser Chemieseiden selbst im Bereich kleiner Dehnungen nicht anwendbar ist. Dieser Sachverhalt ist bei Modellberechnungen zu beachten.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 37 (1986), S. 458-464 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: The influence of the structure on the strength of bulk polyamide 6 is investigated. The strength is characterized as resistance of the material to plastic deformation as well as t o crack propagation. Measurements of the fracture toughness of polyamide 6-injection mouldings within the scope of linear elastic fracture mechanics are reported. Results are discussed in connection with light and electron microscopic investigations especially as to the secondary fracture behaviour.
    Notes: Der Einfluß der Struktur auf die Festigkeit von kompaktem Polyamid 6 wird untersucht. Dabei wird als Festigkeit der Widerstand des Materials einerseits gegen plastische Verformung, andererseits gegen Rißausbritung charakterisiert. Es wird Bruchzähigkeitsmessungen ana PA-6-Spritzgrußteilen im Rahmen der linear-elastischen Bruchmechanik berichtet. Die Ergebnisse werden in Verbindung mit licht- und elektronenmikroskopischen Untersuchungen, insbesondere zum Sekundärbruchverhalten, diskutiert.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 40 (1989), S. 214-221 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: The terms adhesion and bonding strength are scientifically interpreted. The factors influencing on the adhesion and their strength are discussed with the examples of the following systems: Steel-primer-PVC, and Zn, Cr, Al, Cu on PMMA. Correlations between the bonding strength and the electrochemical potential of the metals are established. For the interpretation of the phenomena a “microelectrolyte-model” is developed.
    Notes: Die Begriffe Haftung und Haftfestigkeit werden wissenschaftlich interpretiert. Einflußfaktoren auf die Haftung und ihre Festigkeit werden an den Beispielen Stahl-Haftvermittler-PVC sowie Zink, Chrom, Aluminium und Cupfer zu funktionalisiertem PMMA behandelt. Zur Interpretation der Wechselwirkungen an den Phasengrenzen wird ein neues Adhäsionsmodell, das Mikroelektrolyt-Modell, vorgestellt.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 43 (1992), S. 27-29 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Hochfest/Hochmodulus-Fasern können durch Kaltrecken von UHMW-Polyethylen-Gelfasern erhalten werden. Es wird gezeigt, daß die kristalline Ordnung in diesen Fasern nicht vollkommen ist. Die übermolekulare Struktur wir durch eine ”shish-kebab“ -Morphologie charakterisiert. Die Ergebnisse röntgenographischer und mechanischer Untersuchungen erlauben es, den Reckvorgang durch einen Dreistufenprozeß gekoppelt mit molekularen und fibrillären Gleitvorgängen zu erklären.
    Notes: High strength/high modulus fibres can be prepared by cold drawing of UHMW-PE gel fibres. It is shown that the crystalline order in this fibres is not perfect. The supermolecular structure is characterized by a shish-kebab morphology. Results of X-ray and mechanical investigations permit to explain the drawing process by a three-step mechanism of molecular orientation and stretching coupled with molecular and fibrillar sliding.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 39 (1988), S. 181-183 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: With PE gel-fibres can be achieved draw rations over 20 by cold drawing. The strength level is lower than in the case of hot drawing. First data refer to a modified deformation model of high strength fibres.
    Notes: Polyethylen-Gelfäden können durch Kaltreckung mit Reckgarden weit über 20 gereckt werden. Das damit erzielte Festigkeitsniveau liegt unter dem des heißgereckten Materials. Erste Meßdaten weisen auf ein modifiziertes Deformationsmodell für hochfeste Gelfäden hin.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...