Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (8)
  • Brain tumour  (2)
  • Damage-responsive element  (2)
  • 1
    ISSN: 1432-1920
    Keywords: Key words Magnetic resonance imaging, diffusion-weighted ; Brain abscess ; Brain tumour ; Cysticercosis ; Radiation necrosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Our purpose was to investigate the signal intensities of cystic or necrotic intracranial lesions on diffusion-weighted MRI (DWI) and measure their apparent diffusion coefficients (ADC). We examined 39 cystic or necrotic intracranial lesions in 33 consecutive patients: five malignant gliomas, seven metastases, two other necrotic tumours, a haemangioblastoma, three epidermoids, an arachnoid cyst, seven pyogenic abscesses, 12 cases of cysticercosis and one of radiation necrosis. DWI was performed on a 1.5 T unit using a single-shot echo-planar spin-echo pulse sequence with b 1000 s/mm2. The signal intensity of the cystic or necrotic portion on DWI was classified by visual assessment as markedly low (as low as cerebrospinal fluid), slightly lower than, isointense with, and slightly or markedly higher than normal brain parenchyma. ADC were calculated in 31 lesions using a linear estimation method with measurements from b of 0 and 1000 s/mm2. The cystic or necrotic portions of all neoplasms (other than two metastases) gave slightly or markedly low signal, with ADC of more than 2.60 × 10−3 mm2/s. Two metastases in two patients showed marked high signal, with ADC of 0.50 × 10−3 mm2/s and 1.23 × 10−3 mm2/s, respectively. Epidermoids showed slight or marked high signal, with ADC of less than 1.03 × 10−3 mm2/s. The arachnoid cyst gave markedly low signal, with ADC of 3.00 × 10−3 mm2/s. All abscesses showed marked high signal, with ADC below 0.95 × 10−3 mm2/s. The cases of cysticercosis showed variable signal intensity; markedly low in five, slightly low in three and markedly high in four.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Acta neurochirurgica 139 (1997), S. 88-89 
    ISSN: 0942-0940
    Keywords: Brain tumour ; cardiac tumour ; myxofibrosarcoma ; metastasis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1617-4623
    Keywords: Key wordsSchizosaccharomyces pombe ; DNA-damage inducibility ; Damage-responsive element ; Upstream activating sequence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract The Schizosaccharomyces pombe rhp51 + gene encodes a recombinational repair protein that shares significant sequence identities with the bacterial RecA and the Saccharomyces cerevisiae 1RAD51 protein. Levels of rhp51 + mRNA increase following several types of DNA damage or inhibition of DNA synthesis. An rhp51:: ura4 fusion gene was used to identify the cis-acting promoter elements involved in regulating rhp51 + expression in response to DNA damage. Two elements, designated DRE1 and DRE2 (for damage-responsive element), match a decamer consensus URS (upstream repressing sequence) found in the promoters of many other DNA repair and metabolism genes from S. cerevisiae. However, our results show that DRE1 and DRE2 each function as a UAS (upstream activating sequence) rather than a URS and are also required for DNA-damage inducibility of the gene. A 20-bp fragment located downstream of both DRE1 and DRE2 is responsible for URS function. The DRE1 and DRE2 elements cross-competed for binding to two proteins of 45 and 59 kDa. DNase I footprint analysis suggests that DRE1 and DRE2 bind to the same DNA-binding proteins. These results suggest that the DRE-binding proteins may play an important role in the DNA-damage inducibility of rhp51 + expression.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1617-4623
    Keywords: Schizosaccharomyces pombe ; DNA-damage inducibility ; Damage-responsive element ; Upstream activating sequence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract TheSchizosaccharomyces pombe rhp51 + gene encodes a recombinational repair protein that shares significant sequence identities with the bacterial RecA and theSaccharomyces cerevisiae RAD51 protein. Levels ofrhp51 + mRNA increase following several types of DNA damage or inhibition of DNA synthesis. Anrhp51::ura4 fusion gene was used to identify the cis-acting promoter elements involved in regulatingrhp51 + expression in response to DNA damage. Two elements, designated DRE1 and DRE2 (fordamage-responsiveelement), match a decamer consensus URS (upstream repressing sequence) found in the promoters of many other DNA repair and metabolism genes fromS. cerevisiae. However, our results show that DRE1 and DRE2 each function as a UAS (upstream activating sequence) rather than a URS and are also required for DNA-damage inducibility of the gene. A 20-bp fragment located downstream of both DRE1 and DRE2 is responsible for URS function. The DRE1 and DRE2 elements cross-competed for binding to two proteins of 45 and 59 kDa. DNase I footprint analysis suggests that DRE1 and DRE2 bind to the same DNA-binding proteins. These results suggest that the DRE-binding proteins may play an important role in the DNA-damage inducibility ofrhp51 + expression.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 23 (1992), S. 329-338 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Influence of grain size on mechanical properties and dry oscillating sliding wear of Al2O3-ceramicsSpecimens with average grain sizes varying between about 0.8 μm and 12 μm were produced by cold isostatic pressing of high purity Al2O3-powder followed by sintering between 1300°C and 1700°C. Hardness, Young's modulus, bending strength and fracture toughness were measured as a function of average grain sizes. Tribological tests were carried out on the different microstructures at normal laboratory air and room temperature by using a ring-on-block tribometer.Experimental results showed the dependence of mechanical properties on grain size, hardness and bending strength obeying a Hall-Petch type relation, approximately. Coefficient of friction was relatively independent of grain size under the test conditions used. However, wear intensity increased substantially if a critical grain size was surpassed. This was due to a change in mechanisms of material removal which was confirmed by scanning electron microscopical studies of the worn surfaces.
    Notes: Aus hochreinem Al2O3-Pulver wurden durch kaltisostatisches Pressen und Variation der Sintertemperatur zwischen 1300°C und 1700°C Formkörper mit unterschiedlichen mittleren Korngrößen zwischen etwa 0,8 und 12 μm hergestellt. Untersucht wurde der Einfluß der Korngröße auf mechanische und tribologische Eigen-schaften.Die Ergebnisse zeigten, daß mechanische Eigenschaften wie Härte, E-Modul, Biegebruchfestigkeit und Bruchzähigkeit von der Korngröße bzw. den Sintertemperaturen abhingen, wobei im Fall der Härte und Bruchfestigkeit näiherungsweise eine Hall-Peteh-Beziehung vorlag. Während die Reibungszahl relativ unabhängig von der Korngröße war, trat in der Verschleißintensität aufgrund geänderter Mechanismen ein starker Anstieg mit zunchmender Korngröße auf. Rasterelektronenmikroskopische Untersuchungen zeigten, daß der Verschleiß durch plastische Verformung, Mikrobruch, Kornfragmentierung und Deckschichten beeinflußt wurde.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The present study was conducted to compare the push-out strength of the treated and control samples obtained after implantation of intramedullary rod in canine femurs with bone cement to simulate the femoral stem implantation for 2 weeks, 3 and 6 months. Contralateral femur served as control. The result showed a significant decrease in push-out interfacial strength after shock wave treatment (average 48.4% decrease compared with control, p 〈 0.0001) which is similar to the in vitro results. There was no significant difference if the shock treatment was applied and left for 2 weeks or 4 weeks compared to the ones tested immediately after sacrifice. There were some soft tissue damage immediately following shock treatment in the focal area but this returned to normal in 2 weeks. Human cadaveric femoral bones and the canine bone (the dosage level was higher for the human bone than canine). The number of impacts used to extract the bone cement plug out of a human femur segment (5-cm long) decreased about 68% at 23 and 25 kV treatment power level. These preliminary studies indicate that the shock wave can be utilized to reduce the interfacial strength of the bone and bone cement although more studies are needed to assess its efficacy in terms of cost, long-term effect on patients and the exact mechanism of the loosening before this technique can be used clinically.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 2 (1991), S. 161-170 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In order to apply the extracorporeal shock wave lithotripter (ECWSL) technique to the loosening of the bone-cement interface for the extraction of the cement during revision arthroplasty it is essential to know the dose-response characteristics. The present study shows that the number of shocks needed to break the interface between a 2- and 6-mm-thick bovine femoral bone and bone cement is similar to the fatigue behavior of a material, that is, Log(N) = C(kV) + D, where N is the number of shock impulses, kV is the power setting of the lithotripter machine in kilovolts, and C and D are constants. Iso-pressure distribution of the traveling shock wave front through a simulated bone in a Plexiglass® tube using Fuji® pressure film showed quantitative pressure contours from which one can understand the effective area of shock wave and its distribution. The most effective area of the shock wave was about 1.5 cm in diameter at 23 and 25 kV with pressure at least 7.0 MPa which is more than sufficient to break the bone-cement interface in tension.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In this paper we have reviewed the feasibility of using a shock wave lithotripter to loosen the interface between the bone and acrylic bone cement for revision arthroplasty. We have reviewed the physics of shock wave and its applications in medicine, especially its interaction with tissues. The calculations show that the energy is greatly reduced at the interface both in the soft tissue-bone interface and cement-bone interface. On the other hand, a tensile and compressive pressure can be operated at the cement-bone interface that can cause the interface to break if the pressure exceeds the tensile strength of the cement-bone interface.Subsequent papers will deal with in vitro and in vivo application of the shock wave in the treatment of the cement-bone interface in order to weaken it and consequently for easier extraction of bone cement from the intramedullary canal.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 959-965 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Liver cell transplantation may provide a means to replace lost or deficient liver tissue, but devices capable of delivering hepatocytes to a desirable anatomic location and guiding the development of a new tissue from these cells and the host tissue are needed. We have investigated whether sponges fabricated from poly-L-lactic acid (PLA) infiltrated with polyvinyl alcohol (PVA) would meet these requirements. Highly porous sponges (porosity = 90-95%) were fabricated from PLA using a particulate leaching technique. To enable even and efficient cell seeding, the devices were infiltrated with the hydrophilic polymer polyvinyl alcohol (PVA). This reduced their contact angle with water from 79 to 23°, but did not inhibit the ability of hepatocytes to adhere to the polymer. Porous sponges of PLA infiltrated with PVA readily absorbed aqueous solutions into 98% of their pore volume, and could be evenly seeded with high densities (5 × 107 cells/mL) of hepatocytes. Hepatocyte-seeded devices were implanted into the mesentery of laboratory rats, and 6 ± 2 × 105 of the hepatocytes engrafted per sponge. Fibrovascular tissue invaded through the devices' pores, leading to a composite tissue consisting of hepatocytes, blood vessels and fibrous tissue, and the polymer sponge. © 1995 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 3 (1991), S. 909-916 
    ISSN: 1040-0397
    Keywords: Indium ; potentiometry ; membrane ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The potentiometric anion responses of polymeric membranes doped with various indium (III)-porphyrin structures are examined. The appropriate membranes are prepared by incorporating 1.0 wt % of the In(III)-porphyrins in plasticized poly(vinyl chloride) films. When such membranes are incorporated within standard ion selective electrode bodies, the resulting electrodes display non-Hofmeister anion selectivity, with a particularly enhanced and super-Nernstian response to chloride. Among those porphyrins investigated, membranes doped with chloro(octaethylporphyrinato)indium(III) yield the largest and most reproducible potentiometric anion responses. These same membrane electrodes exhibit negligible response to protons (or hydroxide) in the range of pH 4.5-9.0. When utilized as a flow-injection detector in conjunction with a protein diluent/buffer stream, the In(III)-porphyrin based electrodes may be used to determine chloride levels in human serum samples.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...