    Electronic Resource
    Electronic Resource
    Springer
    Archives of gynecology and obstetrics 237 (1985), S. 75-83 
    ISSN: 1432-0711
    Keywords: Breast cancer ; Morphological features ; Grading ; Prognostic index
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A group of 156 patients suffering from breast cancer with axillary metastases was studied for connections between the morphological structure of the tumor and the spreading of the disease on the one hand and duration of remission on the other hand. The statistical analysis shows that the summary WHO-grading proves to be the most indicative prognostic factor next to the number of affected lymph nodes and tumor size. Definition of a prognostic index from these factors leads to a more precise prognostical distinction of the collective.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of cancer research and clinical oncology 119 (1993), S. 415-420 
    ISSN: 1432-1335
    Keywords: Estrogen receptor ; Progesterone receptor ; Immunobiochemical assay ; Nuclear receptors ; Breast cancer ; Endometrial cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The exact knowledge of hormone receptor status is critical for therapeutic strategies in hormone-dependent tumors. The influence of tamoxifen on estrogen receptor concentration has to be taken into account when evaluating results in tamoxifen-treated patients. We studied the receptor modulation of tumors xenotransplanted into nude mice (one breast and one endometrial carcinoma) after injection of 50 μg tamoxifen/mouse. To differentiate between unoccupied and occupied receptors, determinations were done by an enzyme immunoassay for the estrogen receptor under low-and high-salt extraction. With low-salt extraction we found a temporary decrease of the estrogen receptor concentration within the first hours after tamoxifen treatment. This decrease lasted for several days before recovery to pretreatment levels occurred. The hormone-receptor complexes, tightly bound to acceptor sites of the DNA, increased more than 15 times within 24 h. These values remained at increased levels for 2–7 days, after which a decrease to initial levels was observed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Keywords: Positron emission tomography ; Fluorine-18 fluorodeoxyglucose ; Standardized uptake value ; Semiquantitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract While the evident advantages of absolute metabolic rate determinations cannot be equalled by static image analysis of fluorine-18 fluorodeoxyglucose positron emission tomographic (FDG PET) studies, various algorithms for the normalization of static FDG uptake values have been proposed. This study was performed to compare different normalization procedures in terms of dependency on individual patient characteristics. Standardized FDG uptake values (SUVs) were calculated for liver and lung tissue in 126 patients studied with wholebody FDG PET. Uptake values were normalized for total body weight, lean body mass and body surface area. Ranges, means, medians, standard deviations and variation coefficients of these SUV parameters were calculated and their interdependency with total body weight, lean body mass, body surface area, patient height and blood sugar levels was calculated by means of regression analysis. Standardized FDG uptake values normalized for body surface area were clearly superior to SUV parameters normalized. for total body weight or lean body mass. Variation and correlation coefficients of body surface area-normalized uptake values were minimal when compared with SUV parameters derived from the other normalization procedures. Normalization for total body weight resulted in uptake values still dependent on body weight and blood sugar levels, while normalization for lean body mass did not eliminate the positive correlation with lean body mass and patient height. It is concluded that normalization of FDG uptake values for body surface area is less dependent on the individual patient characteristics than are FDG uptake values normalized for other parameters, and therefore appears to be preferable for FDG PET studies in oncology.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1619-7089
    Keywords: Breast cancer ; Scintimammography ; Technetium-99m methoxyisobutylisonitrile ; Mammography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of the study was to compare the diagnostic accuracy of scintimammography with technetium-99m methoxyisobutylisonitrile (MIBI; SMM) in the detection of primary breast cancer with that of mammography (MM) and magnetic resonance imaging (MRI). Fifty-six patients with suspected lesions detected by palpation or MM were included in the study. Within the 4 weeks preceding excisional biopsy, MM and MRI were performed in all patients. Between 5 and 10 min after the injection of 740 MBq99mTc-MIBI, SMM in the prone position was performed. In the total group of 56 patients, 43 lesions were palpable, while 13 were non-palpable but were detected by MM. Breast cancer was confirmed by histopathology in 27 of the patients (22 palpable and 5 non-palpable carcinomas). The tumour size ranged from 6 to 80 mm in diameter. For non-palpable lesions, the sensitivity of SMM, MM and MRI was 60%, 60% and 100%, respectively, while the specificity was 75%, 25% and 50%, respectively. For palpable breast lesions, all methods showed high sensitivity (SMM 91%, MM 95%, MRI 91%) but SMM demonstrated significantly higher specificity (SMM 62%, MM 10%, MRI 15%). In two mammographically negative tumours (dense tissue), SMM showed a positive result. In comparison to MRI, one additional carcinoma could be diagnosed by SMM. It may be concluded that for palpable breast lesions, the diagnostic accuracy of SMM is superior to that of MM and MRI. Through the complementary use of SMM it is possible to increase the sensitivity for the detection of breast cancer and multicentric disease. In patients in whom the status of a palpable breast mass remains unclear, SMM may help to reduce the amount of unnecessary biopsies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1619-7089
    Keywords: Fluorine-18 fluorodeoxyglucose ; Positron emission tomography ; Technetium-99m methoxyisobutylisonitrile ; Scintimammography ; Breast cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this study was to compare, in breast cancer patients, the diagnostic accuracy of positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) and scintimammography (SMM) using technetium-99m methoxyisobutylisonitrile (MIBI). A total of 20 patients (40 breasts with 22 lesions) were evaluated serially with MIBI and, on the following day, with FDG. For SMM, planar and single-photon emission tomography imaging in the prone position was performed starting at 10 min following the injection of MIBI (740 MBq). For PET, scans were acquired 45–60 min after the injection of FDG (370 MBq) and attentuation correction was performed following transmission scans. Results from SMM and PET were subsequently compared with the histopathology results. True-positive results were obtained in 12/13 primary breast cancers (mean diameter=29 mm, range 8–53 mm) with both FDG and MIBI. False-negative results were obtained in two local recurrences (diameter 〈9 mm) with both FDG and MIBI. In benign disease, FDG and MIBI did not localize three fibrocystic lesions, two fibroadenomas and one inflammatory lesion (true-negative), but both localized one fibroadenoma (false-positive). Collectively, the results demonstrate a sensitivity of 92%, and a specificity of 86%, for primary breast cancer regardless of whether FDG or MIBI was used. In contrast to MIBI scintigraphy, FDG PET scored the axillae correctly as either positive (metastatic disease) or negative (no axillary disease) in all 12 patients. The tumour/non-tumour ratio for MIBI was 1.97 (range 1.43–3.1). The mean standard uptake value (SUV) for FDG uptake was 2.57 (range 0.3–6.2). The diagnostic accuracy of SMM was equivalent to that of FDG PET for the detection of primary breast cancer. For the detection of in situ lymph node metastases of the axilla, FDG seems to be more sensitive than99mTc-MIBI.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1619-7089
    Keywords: Key words: Breast cancer ; Fluorine-18 fluorodeoxyglucose ; Positron emission tomography ; Tumour-to-non-tumour ratio ; Contrast parameters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) has proven useful in the differentiation of various tumour entities, including breast cancer. In patients with primary breast cancer we performed a 3-h imaging protocol to examine possible improvements in tumour detectability and image contrast. Twenty-nine patients with primary breast cancer with a diameter of ≥2 cm that was demonstrated to be malignant by biopsy or surgery were injected with 370–740 MBq 18F-FDG and scanned in the prone position. Data were acquired 0–40 min, 1.5 h and 3.0 h after injection. After correction for measured attenuation, decay and scatter and iterative reconstruction, standardised uptake values (SUVs) and tumour-to-non-tumour and tumour-to-organ ratios were calculated. Visual analysis was performed using transverse, sagittal and coronal slices as well as 3D reprojection images. Tumour-to-non-tumour and tumour-to-organ ratios were significantly higher for the 3-h images than for the 1.5-h images. SUVs did not increase to the same extent. Lesion detectability was 83% in 1.5-h images compared to 93% in 3-h images. We conclude that tumour contrast in breast cancer is improved by starting the PET acquisition at 3 h p.i. rather than at 1.5 h p.i.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1619-7089
    Keywords: Key words: Fluorine-18 fluorodeoxyglucose ; Positron emission tomography ; Technetium-99m methoxyisobutylisonitrile ; Scintimammography ; Breast cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of this study was to compare, in breast cancer patients, the diagnostic accuracy of positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) and scintimammography (SMM) using technetium-99m methoxyisobutylisonitrile (MIBI). A total of 20 patients (40 breasts with 22 lesions) were evaluated serially with MIBI and, on the following day, with FDG. For SMM, planar and single-photon emission tomography imaging in the prone position was performed starting at 10 min following the injection of MIBI (740 MBq). For PET, scans were acquired 45–60 min after the injection of FDG (370 MBq) and attentuation correction was performed following transmission scans. Results from SMM and PET were subsequently compared with the histopathology results. True-positive results were obtained in 12/13 primary breast cancers (mean diameter=29 mm, range 8–53 mm) with both FDG and MIBI. False-negative results were obtained in two local recurrences (diameter 〈9 mm) with both FDG and MIBI. In benign disease, FDG and MIBI did not localize three fibrocystic lesions, two fibroadenomas and one inflammatory lesion (true-negative), but both localized one fibroadenoma (false-positive). Collectively, the results demonstrate a sensitivity of 92%, and a specificity of 86%, for primary breast cancer regardless of whether FDG or MIBI was used. In contrast to MIBI scintigraphy, FDG PET scored the axillae correctly as either positive (metastatic disease) or negative (no axillary disease) in all 12 patients. The tumour/non-tumour ratio for MIBI was 1.97 (range 1.43–3.1). The mean standard uptake value (SUV) for FDG uptake was 2.57 (range 0.3–6.2). The diagnostic accuracy of SMM was equivalent to that of FDG PET for the detection of primary breast cancer. For the detection of in situ lymph node metastases of the axilla, FDG seems to be more sensitive than 99mTc-MIBI.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability