    Chromatographia 31 (1991), S. 285-292 
    ISSN: 1612-1112
    Schlagwort(e): Colum liquid chromatography ; Ethylenethiourea in ground water ; Column switching ; Trace analysis ; Screening for ETU
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Column-switching with two C18 separation columns combined with UV detection at 233 nm has been used to determine ETU in ground water samples. The direct assay of ETU (limit of detection, 1 ppb) takes less than 10 min. For the determination of ETU down to a level of 0.1 ppb, preconcentration of ETU is achieved by a liquid-liquid extraction procedure allowing the analysis of at least 12 water samples per day. For both methods (1-ppb and 0.1-ppb level), the overall recovery (96 and 82%), the repeatability (4.5 and 4.3%) and the reproducibility (5.0 and 7.9%) are satisfactory (n=18 and 28, respectively). More than one hundred samples of ground water were analysed during a 10-month period; over 0.1 ppb of ETU (range, 0.1–300 ppb) was found in 30% of the samples tested.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1612-1112
    Schlagwort(e): Liquid chromatography ; Chlorophenols in water ; Preconcentration ; Post-column photochemical dechlorination ; Electrochemical, UV and fluorescence detection ; Column switching
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A specific HPLC method has been developed for the trace analysis of lower chlorinated aromatic compounds. The method consists of an on-line preconcentration and a post-column reaction step. On-line preconcentration of mono- and dichlorophenols from aqueous samples has been performed using PRP1, a divinylbenzene-styrene copolymeric sorbent as packing material for both pre-and analytical column. Enrichment factors of over 300 were obtained compared to regular (100 μl) loop injections, even for the highly polar monochlorophenols. After reversed-phase separation, post-column photochemical dechlorination is carried out directly in the eluent stream, using a photochemical reactor. Upon dechlorination, fluorescent products are formed, which can be detected selectively. The resulting fluorescence signal shows a linear response to the quantity of solute present over 2 to 3 orders of magnitude (correlation coefficients: 0.990–0.98). For the mono- and dichlorophenols, the detection limit of the photoconversion method is in the lower nanogram range. The method is especially suitable for the analysis of complex matrices such as effluent water samples or biological fluids containing traces of the polar chloroaromatic compounds together with large amounts of other constituents, which interfere when using more general methods of detection like UV absorption. The potential of this technique for automation has been demonstrated by using a microprocessor-controlled column switching unit.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1612-1112
    Schlagwort(e): Column liquid chromatography ; Electrodialytic sample treatment ; On-line coupling
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary An electrodialytic sample treatment method coupled on-line with high-performance liquid chromatography (EDIST-HPLC) is discussed in this paper. The performance of EDIST as a function of the donor-phase (sample solution) flow rate, the voltage applied over the electrodialysis block, and the time of dialysis has been studied using the basic drug ephedrine as a model compound. Enrichment of the analyte by a factor of 10–20 was possible. The determination of human plasma spiked with ephedrine is briefly discussed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Column liquid chromatography ; On-line coupling ; Ion-exchange membrane ; Ion-pair reagent
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant in the membrane was tetrabutylammonium hydroxide dissolved in acetonitrile/water, which effects an anion-exchange of methanesulphonate ions for regenerant hydroxide ions. The efficiency of the exchange process was found to be 99.9%. This enabled the direct introduction of the LC eluent, free of ions and with the proper acetonitrile/water ratio, into the GC. The applicability of the on-line LC-micromembrane-GC system has been illustrated for the potential drug eltoprazine, which is quantitatively recovered with a coefficient of variation for standard solutions of 3% at the 150 μg/ml analyte level.