Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Multiple sclerosis ; High-dose contrast-enhanced ; magnetic resonance imaging ; Gadolinium-DTPA ; Gadolinium-HP-D03A
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-D03A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-D03A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1459
    Keywords: Key words Multiple sclerosis ; Magnetic resonance imaging ; Disease activity ; Fast spin echo ; Fast fluid-attenuated inversion ; recovery ; Reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Previous studies have addressed the question of the precision in assessing multiple sclerosis (MS) activity by counting enhancing lesions on gadolinium enhanced brain magnetic resonance imaging (MRI). However, counting the active lesions on serial unenhanced MRI obtained by various pulse sequences has not been yet considered. We compared the interobserver levels of agreement in reporting active MS lesions on serial enhanced and unenhanced MRI to assess whether the use of various unenhanced techniques may change the degree of interobserver measurement reproducibility. Dual-echo conventional spin echo (CSE), dual-echo fast spin echo (FSE), fast fluid-attenuated inversion recovery (FLAIR) and Gd-enhanced T1-weighted brain MRI were obtained from five MS patients at baseline and monthly for 2 months. Six experienced observers independently identified and counted active MS lesions on the two follow-up MRI scans. Active lesions were considered to be all the enhancing lesions and any new or enlarging lesion on enhanced and unenhanced scans. Interobserver levels of agreement were calculated by weighted κ values. Very good agreement was reached only for counting total and new Gd-enhancing lesions. Good agreement was achieved for counting new lesions on the three unenhanced techniques, whereas the agreement for counting enlarging lesions was poor with all the MRI techniques. The level of agreement was significantly heterogeneous for various MRI techniques but not for various lesion sites. These results confirm that counting enhancing lesions is the most reliable method for assessing MS activity, but the use of any of the available unenhanced MRI techniques did not result in different levels of interobserver agreement when reporting new and enlarging MS lesions on serial scans.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...