Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Laryngeal reconstructive surgery  (2)
  • Injector respiration  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 253 (1996), S. 481-487 
    ISSN: 1434-4726
    Keywords: Bone plates ; Bone screws ; Laryngeal cartilage ; Laryngeal reconstructive surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this study was to investigate and develop techniques for stabilization and reconstruction of laryngeal defects with a method similar to osteosynthesis. In an anatomical study, 400 extrusion forces of sutures and various screws (Howmedica) were measured in the thyroid cartilage of fresh cadavers. A new screw was then especially designed for cartilage and a new technique was developed for stabilizing cartilage, using a screw-nut made out of bone. To date, 30 patients have undergone chondrosynthetic reconstruction of the larynx. Measurements of extrusion forces were found to depend on the degree of calcification present in the area of the laryngeal skeleton examined and the type of fixation device used. Good clinical results were achieved in all 30 patients studied and depended on stabilization of the two sides of the thyroid cartilage after thyrotomies, bridging of laryngeal defects and splinting of laryngeal fractures. Besides the increased extrusion forces the advantages of chondrosynthesis lay within the possibilities of axial stabilization and exact bridging of defects with or without implants.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 254 (1997), S. 463-465 
    ISSN: 1434-4726
    Keywords: Laryngeal cartilage ; Laryngeal reconstructive surgery ; Chondrosynthesis ; Plate and screw fixation systems
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Two patients treated for laryngeal tumors at the University of Lübeck are presented. Both underwent laryngeal reconstructions with plate and screw fixation systems immediately following partial laryngectomies. Recurrent disease was found at 14 and 55 months, respectively, and was subsequently managed by total laryngectomy. The laryngectomy specimens with the plate and screws in situ were evaluated histopathologically, paying special attention to the reaction of local tissue to the implants. Findings showed that the metallic plates were fixed with screws in the bony trabeculae of the laryngeal skeleton. The histological response showed primary wound healing without evidence of sequestration or implant loosening, as often associated with excess mechanical stress. Furthermore, there were no signs of tissue necrosis or widespread chronic inflammation. In both patients, a small discrete area of chronic inflammation and soft tissue fibrosis was noted adjacent to the screw heads. This study supports our previously documented clinical experience that the use of chondrosynthetic techniques is almost complication-free and is an ideal system for performing precise anatomical reconstruction of the laryngeal skeleton.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 225 (1979), S. 103-106 
    ISSN: 1434-4726
    Keywords: New laryngoscope ; Injector respiration ; Neues Laryngoskop ; Injektionsbeatmung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Für die Mikrolaryngoskopie wurde das Keinsasser-Laryngoskop seitlich aufgetrennt, über Spindeltriebe ist der Durchmesser zwischen 15 und 26 mm verstellbar. Die untere Spatelhälfte ist abklappbar gestaltet. Es wird kurz der Arbeitsplatz beschrieben. Die bei uns an über 1000 Patienten erprobte Injektionsbeatmung zeigt auch beim offenen Rohr normale Blutgaswerte. Die Kombination der Vorteile des Kleinsasser-Rohres mit der Killianschen Schwebelaryngoskopie bietet durch die laterale Schlitzung des Rohres wesentlich mehr Platz für die mikrochirurgischen Instrumente.
    Notes: Summary A new laryngoscope was constructed in order to improve visualization of the larynx and to adjust the instrument to individual situation. The Kleinsasser laryngoscope was divided into two parts. The width between these two halfs can be changed by screws. Because the laryngoscope is open laterally there is more space for the operator and shorter instruments can be used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...