Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1246
    Keywords: Color vision loss ; Occupational exposure limit ; Organic solvent ; Tetrachloroethylene ; Toluene
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Possible color vision loss was examined with Lanthony's new color test and Ishihara's color vision test in 261 solvent workers and 120 controls (48 men and 72 women). The solvent workers were exposed to either predominantly toluene [46 ppm as geometric mean (GM); 63 men and 111 women], tetrachloroethylene alone (13 ppm; 30 men and 34 women), or a mixture (14 men and 9 women) of tetrachloroethylene (12 ppm) and trichloroethylene (7 ppm). The only instances of color vision loss that were detected in either the exposed workers or the controls were six cases of red-green loss (all in men). These six cases of red-green loss showed an unbiased distribution between the exposed workers and the nonexposed controls.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 63 (1992), S. 455-460 
    ISSN: 1432-1246
    Keywords: Air monitoring ; Biological monitoring ; Diffusive sampling ; Dimethylformamide ; Monomethylformamide ; Urinalysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The relationship between the 8-h time-weighted average (TWA) intensity of exposure toN, N-dimethylformamide (DMF) vapor (with little possibility of skin contact with liquid DMF) and the subsequent excretion ofN-monomethylformamide (MMF) precursor in shift-end urine samples was examined in 116 workers exposed to DMF and 92 workers exposed to DMF in combination with toluene. Urinary MMF level was examined also in 42 non-exposed subjects. The TWA vapor concentration in breathing zone air of each worker was successfully measured by means of a recently developed diffusive sampler in which water was used as an absorbent. The examination of gas chromatographic (GC) conditions for MMF determination showed that the formation of MMF was not saturated when the injection port temperature was set at 200°C, reached a plateau at 250°C, and showed no additional increase at 300°C. There was a linear relationship between DMF in air and MMF in urine with a regression equation ofy =1.65x + 1.69 (r = 0.723,P〈0.01), wherey is MMF (unit; mg/l, uncorrected for urine density) in urine andx is DMF (ppm) in air, when only those exposed to DMF were selected, and the injection port temperature was set at 250°C. From this equation, it was possible to estimate that about 10% of the DMF absorbed will be excreted into urine as the MMF precursor. The slope of the regression line was significantly smaller among those exposed to DMF and toluene in combination as compared with those with DMF exposure only.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...