Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 280 (1973), S. 239-252 
    ISSN: 1432-1912
    Schlagwort(e): Ca-Inward Current ; EC Coupling ; Cardiac Excitability ; Verapamil ; D 600-KCl Depolarization ; g Ca
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Cat papillary muscles were depolarized by raising the external K concentration so that resting potential went from about −80 mV to −50 mV. This caused inactivation of the transmembrane Na system. The remaining Ca-mediated action potentials showed greater overshoot, reduced upstroke velocity and action potential duration, and higher threshold of excitation. A graded electrical response to stimulous strength was also present. These action potentials depended mainly on the extracellular Ca concentration [16]. Further, the specific Ca-antagonistic compounds verapamil and D 600 [10] or Ca-with-drawal completely abolished the ability of the K-depolarized fibres to respond to stimulation with propagated electrical activity. Conversely, extra Ca, epinephrine or isoproterenol overcame this inhibitory effect by increasing the Ca transmembrane influx. Also, within 1 min after returning treated muscles to normal K 0 Tyrode solution, the Na system was reactivated and apparently normal electrical activity possible. In this case, Ca-withdrawal and the Ca-antagonists lose their electrical inhibitory influence, while excitation-contraction uncoupling still persist.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European journal of orthopaedic surgery & traumatology 8 (1998), S. 133-139 
    ISSN: 1432-1068
    Schlagwort(e): Total hip replacement ; Results ; Aseptic loosening ; Cemented ; Uncemented ; Titanium
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Mid- and long term stability is still the major challenge in total hip replacement (THR). A consecutive series of cemented 250 cases and of uncemented 250 cases was analyzed in a prospective follow-up study. The femoral component of the BiCONTACT hip stem system with the same design for cemented and uncemented implantation was used. While the cemented stems had a smooth surface, the cementless implants were proximally coated with a microporous titanium plasmaspray (Plasmapore®). Follow-up time averaged 7 years for cemented and 6.5 years for uncemented THRs. Follow-up rate was 88.7% in cases treated with cemented stems and 93.1% in cases treated with an uncemented stem. The rate of aseptic loosening was 1.2% for the cemented version and 0.4% for the uncemented one. Radiological loosening could be observed in another 1.2% of the cemented stems but was not found in the uncemented cases. Our data suggest excellent midterm stability of both the cemented and the uncemented version of the BiCONTACT hip stem system. Early aseptic loosening especially of the cemented titanium alloy straight stem has not occurred in our series as reported recently. The prosthesis design and follow-up time may therefore play an important role. The long-term results for both cemented and uncemented BiCONTACT prostheses of our series are still to be evaluated.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...