Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    ISSN: 1435-1285
    Keywords: Schlüsselwörter Koronarangiographie – Duplexsonographie – Brachialarterie ; Key words Coronary angiography – ultrasound duplex – brachial artery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Diagnostic and interventional heart catheterization in peripheral vascular disease often requires due to iliacal disease additional methods of arterial approach besides the Judkin's technique. The percutaneous catheterization of the brachial artery finds widespread use. A major complication linked with this method is an increased rate of thrombotic occlusions at the puncture site. Thus, we investigated in a prospective set-up the ability of duplex ultrasound to identify predictive risk factors for vascular complications. Over a period of 20 months, 8000 patients referred to heart catheterization were studied. Routine catheterization via the femoral route was contraindicated in 34 out of 8000 mostly due to severe peripheral vascular disease with multiple vascular risk factors (diabetes, hypertention, and smoking). 53 patients who had a comparable low riskprofile served as the control group. The brachial artery was examined by ultrasound duplex for vessel anatomy and diameter at the puncture site before coronary angiography. Both groups (patient and control group) showed in 15% a variable anatomy with a premature division of the brachial artery in 6% proximal of the elbow and in 9% already distal to the axillary artery. Because of reduced diameters of these variable vessels no procedure was carried out at these arms. In all cases the opposite arm was successfully used instead, because the variants were always located only at one arm. The diameter of the brachial artery measured in average 5.0±0.8 mm and 4.8±0.7 mm in patients and controls, respectively. Women had a significantly smaller vessel diameter than men, measuring a difference of 0.4 and 0.6 mm, respectively (p〈0.05). For coronary angiography 6F and 7F arterial sheats were used equally, and in 32% of all cases a coronary intervention was performed. 31 (91%) procedures were carried out without complications; there was a false aneurysm in 1 patient (3%) and an occlusion of the brachial artery at the puncture site in 2 patients (6%). The occluded vessels of two diabetic women had a reduced diameter at the level of 10% of the standard distribution and an unfavorable ratio of sheat-to-vessel-diameter which lead initially to an obstruction of nearly 50% of the vessel lumen during catheterization. Screening of the brachial artery by ultrasound duplex before a percutaneous catheterization for coronary angiography and intervention showed reproducibly the variable anatomy and differences in vessel diameter, which can be risk factors for thrombotic occlusion. Important details for the location of the puncture site and the possible size of the arterial sheat can be obtained, so that coronary interventions with 7F catheter systems are still practicable. This technique is a simple and efficient method to estimate the relative risk of arterial occlusion prior to percutaneous puncture of the brachial artery, especially in a group of patients with severe atherosclerosis and elevated vascular risk-factors.
    Notes: Zusammenfassung Diagnostische und interventionelle Herzkatheteruntersuchungen bei peripherer arterieller Verschlußerkrankung erfordern oft, wegen des Ausmaßes der Arteriosklerose der Beckengefäße, alternative Zugangswege zur Judkinsmethode. Vielfach angewandt wird dabei die perkutane Punktion der Arteria brachialis. Problematisch ist bei diesem Verfahren eine hohe Rate von Gefäßokklusionen, so daß es das Ziel dieser prospektiven Untersuchung war, durch die Duplexsonographie Gefäßparameter als Risiken dieser Komplikation zu erkennen. In 20 Monaten wurde dazu unter 8000 konsekutiven Patienten ein Kollektiv von 34 Patienten mit überwiegender Mehretagensklerose und erhöhtem Risikoprofil (Diabetes mellitus, Hypertonie, Nikotinabusus etc.) identifiziert, bei denen eine Koronarangiographie nach Judkins wegen peripherer Arteriopathie nicht durchführbar war. Vergleichend wurden 53 Normalpersonen untersucht. Im Punktionsbereich der Arteria brachialis erfolgte dazu duplexsonographisch die Darstellung des Gefäßverlaufs und der Lumendiameter. Es zeigten sich in beiden Kollektiven häufige anatomische Varianten der Arteria brachialis mit insgesamt 15% atypischen Aufteilungen des Gefäßes, 6% im Bereich der Ellenbeuge und 9% bereits am Oberarm bis unterhalb der Axilla. Wegen reduzierter Diameter der Endäste wurde, um Komplikationen zu vermeiden, an diesen Armen auf eine Punktion verzichtet. Da die Varianten ausschließlich einseitig waren, konnte immer erfolgreich die kontralaterale Arterie punktiert werden. Die Diameter der Brachialarterien lagen im Mittel bei 5,1±0,8 mm bzw. 4,8±0,7 mm im Patienten- bzw. Kontrollkollektiv. Frauen zeigten jeweils um 0,4 bis 0,6 mm signifikant kleinere Diameter der Brachialarterien (p〈0,05). Zur Koronarangiographie wurden gleich häufig 6-F- und 7-F-Schleusen eingesetzt und in 32% eine PTCA durchgeführt. 31 Katheteruntersuchungen (91%) verliefen komplikationslos, es kam zu 1 Aneurysma spurium (3%) und 2 Gefäßverschlüssen (6%). Die Okklusionen traten bei Diabetikerinnen mit Brachialarterien auf, deren Diameter im Bereich der 10%-Perzentile der Normverteilung lagen und bei einem ungünstigen Lumen-Schleusen-Verhältnis eine bis zu 50%ige Gefäßverlegung durch die Katheterschleuse aufwiesen. Eine duplexsonographische Darstellung der Arteria brachialis vor einer perkutanen Punktion zur Herzkatheteruntersuchung zeigt einfach die variablen anatomischen Verläufe und die Diameterunterschiede des Gefäßes auf, die Risikofaktoren für eine Thrombookklusion darstellen können. Dadurch ergeben sich wichtige Details zur Punktionslokalisation und Auswahl der zu verwendenden Katheterschleuse, so daß bei normalweiten Brachialarterien noch mit 7-F-Schleusen Koronarinterventionen komplikationsarm möglich sind. Vor geplanten transbrachialen Herzkatheteruntersuchungen, insbesondere bei entsprechenden Risikopatienten mit generalisierter, fortgeschrittener Arteriosklerose, ist dieses Verfahren zur Stratifizierung des Okklusionsrisikos eine sehr sinnvolle Maßnahme.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Kardiologie 87 (1998), S. s074 
    ISSN: 1435-1285
    Keywords: Schlüsselwörter Koronare Zirkulation – koronare Flußreserve ; Key words Coronary circulation – coronary flow reserve
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The assessment of coronary flow reserve, defined as the ratio of hyperemic to resting coronary blood flow, allows a more functional analysis of the coronary vasculature in addition to coronary angiography. Three different kinds of cardiac catherization procedures for measurement of coronary flow reserve will be reviewed with respect to reliability, feasibility and clinical significance in the diagnosis and treatment of diseases of coronary conductance and resistive vessels: first, from the techniques utilizing selective catherization of coronary sinus, the thermodilution and the oxymetry have to be considered qualitatively rather than quantitatively because of a large hyperemic blood flow responses. The gas chromatographic argon method provides a more quantitative rationale for the selective measurement of resting and hyperemic coronary flow, and thus to more exact differentiation between a reduced hyperemic vs an increased resting flow as a major cause of a reduced flow reserve. Furthermore, because of reliable reproducibility this approach allows to procede follow up studies to assess impact of therapeutic interventions on coronary flow reserve in individual patients. Second, angiographic methods utilize either densitometry or time-to-arrival measurements of defined boluses of contrast medium. The utility of the TIMI-frame count and of densitometric algorithms will be discussed. These methods offer the advantage of being rather easy to handle and to be performed within routine coronary angiography. However, they can be applied to a only rather small group of patients because of methodological limitations in patients with multivessel disease, with disturbed left ventricular function and with irregular heart rate. Third, this group comprises methods in which devices have to be advanced into coronary circulation such as pressure or doppler guide wires, which allows selective assessment of regional coronary flow and reserve. Currently evaluated approaches to assess significance of coronary stenosis will be discussed. In conclusion, currently different methods for the assessment of coronary flow reserve are avaible in cardiac catherization laboratories and each of these methods provides specific advantages and disadvantages, which have to be considered to select the appropriate approach for the diagnosis of functional disturbances of the coronary conductance and resistance vessels. The obtained functional data on coronary circulation should always be interpretated only in context with myocardial function and clinical symptoms of the individual patient.
    Notes: Zusammenfassung Die Bestimmung der koronaren Flußreserve, dem Verhältnis aus koronarem Blutfluß unter maximaler Vasodilatation und in Ruhe, ist ergänzend zur rein bildmorphologischen, angiographischen Darstellung eine funktionelle Methode zur Diagnostik der koronaren Strombahn. Die derzeit zur Verfügung stehenden Untersuchungsmethoden und deren verschiedenen Techniken werden besonders unter dem Aspekt der klinischen Einsatzmöglichkeiten und der spezifischen Relevanz bei koronarer Makro- und Mikroangiopathie dargestellt. 1. Koronarsinustechniken, wie die Thermodilution oder die Messung der Sauerstoffsättigung, sind aufgrund einer großen Streubreite nur als semiquantitativ anzusehen. Die Argon-Fremdgas-Methode kann durch die quantitative Analyse des absoluten Koronarflusses Störungen der koronaren Mikrozirkulation funktionell untersuchen und läßt Möglichkeiten zu Verlaufskontrollen unter entsprechender Therapie. 2. Von den angiographischen Methoden ist die TIMI-Frame-Count-Methode für die Bestimmung der koronaren Reserve ungeeignet und die Densitometrie kann nur an einem hochselektionierten Kollektiv eingeschränkt Aussagen zur Funktion der koronaren Strombahn ermöglichen. 3. Als intrakoronare Untersuchungsmethode ist neben dem technisch noch nicht ausgereiften Druckdraht besonders der intrakoronare Doppler eine Methode zur Messung der, jedoch regional auf das jeweilige Koronargefäß begrenzten, koronaren Flußreserve. Sie eignet sich vor allem zur Bestimmung der funktionellen Relevanz einer grenzwertigen Koronarstenose und zur Beurteilung des Erfolges nach einer koronaren Intervention. Es gibt keine einheitliche Methode zur Bestimmung der Koronarreserve, sondern jede dieser Methoden sollte mit ihren spezifischen Vor- und Nachteilen bei den entsprechenden Fragestellungen für den jeweiligen Patienten angewendet werden, um eine funktionelle Diagnostik zu ermöglichen, die jedoch nicht isoliert, sondern immer in Bezug zur Myokardfunktion und klinischen Symptomatik des Patienten gesetzt werden muß.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1435-1285
    Keywords: Key words Peripheral vascular complications — cardiac catheterization — percutaneous transluminal angioplasty ; Schlüsselwörter Periphere Gefäßkomplikationen — Herzkatheterisierung — perkutane transluminale Angioplastie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary We analyzed the incidence and management of major vascular complications at the arterial puncture site following diagnostic or interventional cardiac catheterization. 27387 cardiac catheterization procedures were performed for diagnostic (n = 19581) or interventional (n = 7806) purposed at our institution during a 7-year study period. A total number of 114 major vascular complications (0.42%) were identified. In 36 (0.13%) patients an arterial occlusion at the puncture site was detected, 34 patients (0.12%) had severe hematoma (blood transfusion or surgical repair necessary), 32 patients (0.12%) developed false aneurysms, 9 patients (0.03%( with av-fistulas and 3 patients (0.01%) had other complications. The following factors were predictive for a significant increase in the incidence of major vascular complications: Female gender, interventional catheterization using larger introducer sheaths and necessitating effective perioperative doses of heparine, and peripheral vascular disease. Operative repair was necessary in 62 patients (54%), 34 patients (30%) were treated conservatively. In 18 patients (17%) acute vascular occlusion could be managed by percutaneous transluminal balloon dilatation and intravascular thrombolysis of the obstructionn, in 3 patients additional stent-implantation was necessary in the presence of a large occlusive dissection. Overall the rate of clinically significant major vascular complications is low. In the future a greater number of vascular complications at the entry site for cardiac catheterization will be treated with nonoperative methods (e.g. manual compression of pseudoaneurysms or catheter-based techniques for recanalization of acutely occluded vessels).
    Notes: Zusammenfassung Wir analysierten die Inzidenz und Therapie aller in unserer Klinik aufgetretenen signifikanten lokalen Gefäßkomplikationen an der Punktionsstelle nach invasiver diagnostischer und interventioneller Herzkatheterisierung. Während eines 7jährigen Untersuchungszeitraums wurden 27387 Herzkatheteruntersuchungen durchgeführt, es handelte sich um 19581 diagnostische und 7806 interventionelle Herzkatheter. Insgesamt traten bei 114 der insgesamt 27387 Herzkatheterisierungen (0,42%) signifikante periphere lokale Gefäßkomplikationen auf. In 36 Fällen (0,13%) handelte es sich um arterielle Verschlüsse am Ort der Punktion, bei 34 Patienten (0,12%) um bedeutsame Hämatome an der Punktionsstelle (OP oder Bluttransfusion erforderlich), bei 32 Patienten (0,12%) um persistierende Pseudoaneurysmen, bei 9 Patienten (0,03%) um eine AV-Fistel und bei 3 Patienten (0,01%) um andere schwerwiegende Komplikationen. Lokale Gefäßkomplikationen waren deutlich häufiger bei Frauen als bei Männern nachweisbar, außerdem war nach interventioneller Kathetertherapie unter Verwendung großlumiger Schleusen mit der Notwendigkeit einer effektiven Heparintherapie die Häufigkeit von Komplikationen deutlich gegenüber rein diagnostischen Untersuchungen erhöht. Bei vorbestehender arterieller Verschlußkrankheit war die Häufigkeit eines lokalen Gefäßverschlusses erhöht. Eine operative Revision der Gefäßkomplikation war bei 62 Patienten (54%) notwendig, 34 Patienten (30%) wurden konservativ behandelt. Bei 18 Patienten (17%) konnte durch Kathetertechniken (PTA, lokale Lyse, Stent-Implantation) ein Gefäßverschluß eröffnet werden. Insgesamt ist die Inzidenz einer signifikanten lokalen Gefäßkomplikation nach Herzkatheteruntersuchung selten. Zukünftig werden diese vaskulären Komplikationen zunehmend auch durch konservative Maßnahmen (z.B. lolake Kompressionsbehndlung bei Pseudoaneurysmen) oder Kathetertechniken (vor allem zur Rekanalisation von arteriellen Verschlüssen) behandelt werden können.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 394 (1972), S. 13-18 
    ISSN: 0044-2313
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Trans-[CoCl2(en)2] [TlCl4] crystallizes in the monoclinic space group P21/m with Z = 2 and a = 6.431, b = 19.11, c = 6.472 Å, β = 90.0°. The structure consists of isolated units of pseudo-octahedral trans-[CoCl2(en)2]⊕ cations and slightly distorted tetrahedral TlCl4⊖ anions. The TlCl4 anions have C8 point symmetry, but the Tl-Cl bond lengths are virtually equal.
    Notes: Trans-[CoCl2(en)2] [TlCl4] kristallisiert monoklin in der Raum-gruppe P21/m; die zwei Formeleinheiten enthaltende Elementarzelle besitzt die Abmessungen a = 6,431 Å, b = 19,11 Å, c = 6,472 Å und β = 90,0°. Die Struktur wird aus den isolierten Bausteinen des pseudooktraedrischen trans-[CoCl2(en)2]⊕-Kations und des leicht verzerrten tetraedrischen TlCl4⊖-Anions aufgebaut. Das TlCl4-Anion besitzt die Punktsymmetrie Cs; es liegen annähernd gleichlange Tl-Cl-Abstände (2,41 Å) vor.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...